Assembling the remaining thread monitor
Additional Instructions 867/867-M PREMIUM - 00.0 - 07/2018
15
Efka control (class 867 only)
Recommended mode for remaining thread monitor function:
Parameter F-195 on value "3"
Information
A detailed functional description of the remaining thread monitor functions
and the stitch counts can be found in the instructions for use of the DA82GA
or DA321G controls.
Parameter
Value
Function
F-195
0
Remaining thread monitor off
F-195
1
No stop after 1st detection
Bobbin empty
,
after thread cutting, sewing foot down
F-195
2
With stop after 1st detection
Bobbin empty
,
after thread cutting, sewing foot up
F-195
3
With stop after 1st detection
Bobbin empty
,
after thread cutting, sewing foot down
F-195
4
Hook thread monitoring via preset number
of stitches
Light barrier remaining thread monitor control
without function
F-195
1 - 3
085
0 - 9990
Number of stitches for remaining thread
Count from 1st detection
Bobbin empty
until stop
F-195
4
085
0 - 9990
Number of stitches A for hook thread
monitoring
Pre-set number of stitches is counted
downwards to "0". When the value "0" is
reached: Stop at value 0 and after thread
cutting sewing foot down.
086
0 - 9990
Number of stitches B for hook thread
monitoring
Pre-set number of stitches is counted
downwards to "0". When the value "0" is
reached: Stop at value 0 and after thread
cutting sewing foot down.
086
0 - 9990
Number of stitches C for hook thread
monitoring
Pre-set number of stitches is counted
downwards to "0". When the value "0" is
reached: Stop at value 0 and after thread
cutting sewing foot down.