Maintenance
Service Instructions 667 PREMIUM - 03.0 - 01/2018
125
15.3.2 Draining the water condensation
Water condensation accumulates in the water separator (2) of the pressure
controller.
Proper setting
Water condensation must not rise up to the level of the filter element (1).
Check the water level in the water separator (2) on a daily basis.
Fig. 87: Draining the water condensation
To drain water condensation:
1.
Disconnect the machine from the compressed air supply.
2.
Place the collection tray under the drain screw (3).
3.
Loosen the drain screw (3) completely.
4.
Allow water to drain into the collection tray.
5.
Tighten the drain screw (3).
6.
Connect the machine to the compressed air supply.
NOTICE
Property damage from excess water!
Excess water can cause damage to the machine.
Drain water as required.
(1)
- Filter element
(2)
- Water separator
(3)
- Drain screw
①
②
③
Содержание 667 PREMIUM
Страница 1: ...667 PREMIUM Service Instructions...
Страница 10: ...About these instructions 8 Service Instructions 667 PREMIUM 03 0 01 2018...
Страница 28: ...Working basis 26 Service Instructions 667 PREMIUM 03 0 01 2018...
Страница 70: ...Thread cutter 68 Service Instructions 667 PREMIUM 03 0 01 2018...
Страница 98: ...Programming 96 Service Instructions 667 PREMIUM 03 0 01 2018 Fig 62 Connecting adapter to DACcomfort...
Страница 120: ...Programming 118 Service Instructions 667 PREMIUM 03 0 01 2018...
Страница 130: ...Maintenance 128 Service Instructions 667 PREMIUM 03 0 01 2018...
Страница 132: ...Decommissioning 130 Service Instructions 667 PREMIUM 03 0 01 2018...
Страница 134: ...Disposal 132 Service Instructions 667 PREMIUM 03 0 01 2018...
Страница 146: ...Troubleshooting 144 Service Instructions 667 PREMIUM 03 0 01 2018...
Страница 149: ......