Operation
Operating manual H868 Version 00.0 - 07/2013
44
5.15.3 Checking the pneumatic system
Figure 28: Pressure indication in the pressure controller
• Check the pressure at the pressure indicator (1) every day:
• Reference value: 6 bar.
• The pressure must not deviate from the reference
pressure by more than 1 bar.
Risk of environmental damage from oil.
Oil is a pollutant and must not enter the sewage system or
the soil.
Carefully collect waste oil and dispose of the waste oil and
oil-contaminated machine parts in the legally prescribed
manner.
ATTENTION
0
2
8
4
6
10
w
q
(1) - Reference value: 6 bar
(2) - Pressure indicator
Machine damage possible due to incorrect pressure.
An incorrect pressure can cause damage to the machine.
Check the pressure on a daily basis.
Have the pressure adjusted by qualified specialists in
accordance with the information in the
Service manual
if
the pressure deviates from the reference value.
ATTENTION