14.1 Software error messages
The remedial measures are to be processed in the order specified.
Error
Meaning
Possible cause
Remedial measures
Process in the order specified!
E
8
Error table data
Unable to read the table
data
• Save the table data again.
E
1
0
Error sewing pattern
number
The selected sewing pat-
tern is not saved in ROM or
is set to non-readable. The
sewing pattern is "0"
• Press the Reset button to confirm the
sewing pattern number.
E
3
0
Error needle bar
position top
The needle bar is not at the
top position
• Check the connections.
• Turn the needle bar to the top dead center
position.
E
4
0
Error sewing field
Sewing field exceeded
• Press the Reset button.
• Check X/Y scaling.
E
4
2
Error scaling
Sewing length is below
10 mm
• Press the Reset button.
• Check sewing pattern and X/Y scaling.
E
4
5
Error sewing pattern
data
Sewing pattern data cannot
be applied
• Press the Reset button.
• Check ROM.
E
5
0
Pause
Reset button pressed while
sewing.
Sewing machine stopped.
• Press the Reset button.
• Actuate the thread trimmer.
• Restart the sewing process.
E
3
0
2
Error machine head Machine head has moved. • Fold back machine head.
E
3
0
5
Error thread trimmer
position
Thread trimmer blade not
at home position
• Set main switch to OFF.
• Check sensor.
E
3
0
6
Error thread catcher
position
Thread catcher not at home
position
• Set main switch to OFF.
• Check sensor.
E
3
3
2
Error clamp foot
position
Clamp foot not at home
position
• Set main switch to OFF.
• Check sensor.
E
5
0
1
Data read error
Data not available or in the
wrong format
• Save the data to a USB stick again.
E
5
0
2
USB read error
MOT file error
• Save the data to a USB stick again.
E
5
0
3
SUM read error
CHECKSUM data error in
MOT file
• Save the CHECKSUM file to a USB stick
again.
E
5
0
4
End block error
No end block in the MOT
file
• Save the end block file to a USB stick
again.
E
5
0
5
USB read error
USB stick not found
• Set main switch to OFF.
• Set main switch to ON.
• Reinsert USB stick.
E
5
0
6
USB read error
Unable to read U01 ~ U10. • Set main switch to OFF.
• Set main switch to ON.
• Reinsert USB stick.
Содержание 512-211-01
Страница 5: ...Table of Contents Service Instructions 512 211 01 532 211 01 00 0 06 2016 3 14 2 Circuit diagram 73...
Страница 6: ...Table of Contents 4 Service Instructions 512 211 01 532 211 01 00 0 06 2016...
Страница 22: ...Work principles 20 Service Instructions 512 211 01 532 211 01 00 0 06 2016...
Страница 72: ...Maintenance 70 Service Instructions 512 211 01 532 211 01 00 0 06 2016...
Страница 76: ...Appendix 74 Service Instructions 512 211 01 532 211 01 00 0 06 2016 Circuit diagram Sheet 2...
Страница 77: ...Appendix Service Instructions 512 211 01 532 211 01 00 0 06 2016 75 Circuit diagram Sheet 3...
Страница 78: ...Appendix 76 Service Instructions 512 211 01 532 211 01 00 0 06 2016 Circuit diagram Sheet 4...
Страница 79: ...Appendix Service Instructions 512 211 01 532 211 01 00 0 06 2016 77 Circuit diagram Sheet 5...
Страница 80: ...Appendix 78 Service Instructions 512 211 01 532 211 01 00 0 06 2016...
Страница 81: ......