Pre-installation data sheet Zencha_22.07.1

Pre-installation

Pre-installation

INSTALLATION LOCATION / INSTALLATION ROOM

 

> Make sure that the installation location fulfils the following criteria

Doors / external 

access

•   Ensure that doors or other access openings are 

large enough to accommodate transport dimen-

sions, keeping in mind the weight and need for 

sufficient manoeuvring room.

Required area

•   Allow for enough space around the tub for the in-

stallation. 

Floor

•  Completely level.
•  At a right angle to the wall.
•  Note the overall strength of the floor structure 

including the floor finish.

•  There must not be any underfloor heating under 

the tub.

•  Install tubs

 after

 the tiles. (Top edge of finished 

floor).

•   Depending on the combination of tub and whirl 

system it is possible that system components may 

protrude beyond the edge of the tub. We there-

fore recommend installation in a support frame.

•  Tolerances for acrylic: 

As a result of the manu-

facturing process, deviations from the nominal 

dimensions may occur within the limits specified 

in the DIN 198 standard. Please take this into 

account in your planning.

Wall

• Tiled.
•  At a right angle to the tub. 
•  Completely straight.
•  Note the overall strength of the wall structure 

including the wall finish.

WATER INSTALLATION

 

Water connection

•  Connections for the water supply and drains must be in compliance 

with the currently valid standards and public regulations. 

•  Position the water drain (DN 50) flush to the mounting surface or out of 

the wall directly above the mounting surface; see drawing for recom-

mended area. 

MAINTENANCE OPENINGS AND AIR SUPPLY

•  The air supply for the whirl system (ventilation grille/ventilation slot) 

must not be covered. 

ELECTRICAL INSTALLATION 

 DANGER

 Risk of fatal electric shock

 

> Disconnect the power supply while working on the electrical 

components.

 

> The device must be earthed. Earthed appliances must be permanently 

connected to fixed wiring.

 

> Connect the device only to the designated electrical cable.

 

> NEVER touch the power supply line with wet hands.

Pre-installation

 

> Lay a permanent power supply line which must be on a separate 

circuit.

•  The device itself does not have electrical leakage protection func-

tion. The device must be supplied through a residual current device 

(RCD) with a rated residual operating current not exceeding 30 mA.

•  Means for disconnection must be incorporated in the fixed wiring 

in accordance with the wiring rules and have a contact separation 

in all poles that provides full disconnection under overvoltage cat-

egory III conditions outside the prescribed protection zones (0 – 2).

•  Leave 3000 mm of the supply line exposed.

 

> Lay an equipotential bonding cable:

•  Leave 3000 mm of cable exposed.

 

> Select a supply line cross-section based on the connected load on the 

identification plate (2.5 mm – 4 mm).

 

> Confirm that the grounding wire is 10 mm (⅜ ”) longer than the L and 

N wire.

 

> Install a circuit breaker.

Protection zones

600

600

2250*

0

1

2

* Or the height of the highest fixed-location shower head/water outlet, 

whichever is higher.

Electrical data

Whirl system

Rated power with  

standard equipment

Max. rated power, 

fully-equipped

Air System (DuraSolid) 

(# 760XXX XX X AS 00XX)

0.58 kW

0.58 kW

Power supply

# 76XXXX XX X XX XXX

0

220 – 240 V AC, 50 Hz 

# 76XXXX XX X XX XXX

6

220 – 240 V AC, 60 Hz

Fuse

   

 I

N

 = 16 A

RCD

   

 I

ΔN

 ≤ 30 mA

3

Содержание Zencha

Страница 1: ...Pre installation Data Sheet Bathtubs and Whirltubs Zencha ...

Страница 2: ...y a licensed electrician SAFETY INSTRUCTIONS Incorrect handling transport may result in product damage The metal frame and whirl system are not resilient Never hold by the metal frame or whirl system Improper transport can cause damage to the product and or property damage e g leaks Wear appropriate protective clothing Avoid knocks Risk of product and or property damage The breach of local and cou...

Страница 3: ...ended area MAINTENANCE OPENINGS AND AIR SUPPLY The air supply for the whirl system ventilation grille ventilation slot must not be covered ELECTRICAL INSTALLATION DANGER Risk of fatal electric shock Disconnect the power supply while working on the electrical components The device must be earthed Earthed appliances must be permanently connected to fixed wiring Connect the device only to the designa...

Страница 4: ... with the location of the operating unit The back massage is located at the head end depending on the whirl system Custom made designs available on request In such cases we will require a drawing showing the desired layout Duravit will confirm whether the desired layout can be implemented Legend Only Combi Systems The number of operating elements is based on the whirl system and the additional mod...

Страница 5: ...Drain connection mm Inlet connection OG inch Whirlsystem Model No Pre installation Zencha Hot water connection Cold water connection Drain connection Electricity connection 600 600 120 357 156 4 206 5 x 109 x 72 40 50 700462 00 0 00 0000 131 365 167 0 206 5 x 109 x 72 40 50 Air System 760462 00 0 AS 0000 700462 760462 850 x 1600 H C D EC 450 1600 450 90 90 280 620 850 D EC C H 5 ...

Страница 6: ...ain connection mm Inlet connection OG inch Whirlsystem Model No Pre installation Zencha Hot water connection Cold water connection Drain connection Electricity connection 600 600 138 2 348 174 6 206 5 x 109 x 72 40 50 700463 00 0 00 0000 149 2 355 185 2 206 5 x 109 x 72 40 50 Air System 760463 00 0 AS 0000 700463 760463 900 x 1800 H C D EC 500 1800 450 25 25 280 850 900 D EC C H 6 ...

Страница 7: ...kg Shipping dimen sions l x w x h cm Drain connection mm Inlet connection OG inch Whirlsystem Model No Pre installation Zencha Hot water connection Cold water connection Drain connection 630 132 5 380 181 9 197 x 148 x 72 40 50 700464 00 0 00 0000 700464 760464 1250 x 1250 H C D 4 8 0 50 110 110 700 ø 1 2 5 0 C H D ø450 1 1 0 1 1 0 7 ...

Отзывы: