Duratuf TUF 200 Скачать руководство пользователя страница 10

TUF 200 FLOOR (Optional) 

PURPOSE BUILT FLOOR 

Step 1:

 Select  the  two  Floor  Boards  which  have 

checked  out  corners.  Position  at  front  and 
back of the shed so they fit around Studs. 

For  sheds  being  placed  on  a  purpose  built  floor,  we 
recommend  that  the  studs  are  shortened  by  30mm. 
The Wall  Sheets  will  then  protrude  20mm  below  the 
Base  Plate.  This  will  stop  water  flowing  in  between 
the Base Plate and Floor. 
 
If  you  choose  this  option,  the  Floor  should  be  made 
15mm smaller than Base Size. 
 

Note:

  Although  it  is  not  essential,  fitting  Damp 

Proof Course in between the Base Plate and 
the  Floor  will  give  added  protection  against 
moisture. 

i.e. CONCRETE / PLYWOOD 

Step 2:

 Lay  out  remaining  Floor  Boards.  Nail  in 

each  Floor  Board,  two  50mm  nails  each 
end and two into each Floor Joist.  

Содержание TUF 200

Страница 1: ...Quality Made Affordable ASSEMBLY INSTRUCTIONS TUF 200 BASE SIZE 1980mm x 855mm...

Страница 2: ...checklist If you are making your own floor refer to Raised Base Plate section now Do not attempt to build your shed in high winds Beware of sharp edges Protect your eyes and ears Use electric tools w...

Страница 3: ...2 010 x 1 070 Blue 45 x 45 H1 Folded Roof Sheets Roof Sheet Or Yellow 45 x 45 H1 Door Green 45 x 45 H4 Green 45 x 45 H4 DESCRIPTION Clear Roof Panel BASE PLATES Red 70 x 45 H1 Corner Wall Sheets 3 4...

Страница 4: ...te 70x45mm Step 3 Position remaining End Frame on top of plates While someone sup ports frame nail in place using two 75mm nails per join Step 4 Carefully roll frame over onto its base Nail on Back an...

Страница 5: ...Door Jambs Position left hand Door Jamb Flashing at correct measurement from left cladding detail and nail to Top Plate using a 30mm clout Do not fit 50mm nails at this stage Pre drill holes to make n...

Страница 6: ...doorway Rivet to Corner Wall Sheet one rivet top and bottom Posi tion and rivet in place all remaining Wall Sheets ensuring they overlap correctly While holding Front Wall Sheets up against Top Plate...

Страница 7: ...th caution Position Roof Sheets as shown in fig 1 When fitting Clear Panel ensure it OVERLAPS Roof Sheets Rivet sheet joins one rivet 300mm from edge front and back When riveting Clear Panel to Roof S...

Страница 8: ...late Flashing and fit one rivet to top hinge While still holding in position fit one rivet to bottom hinge Step 3 Close door and check it fits correctly If not drill out rivets and make necessary adju...

Страница 9: ...RITY DOOR Optional Step 1 Place shed in final position Check diagonal meas urements are equal and shed is level before fitting door Step 2 Hold Door in position approximately 5mm down from Top Plate F...

Страница 10: ...l Sheets will then protrude 20mm below the Base Plate This will stop water flowing in between the Base Plate and Floor If you choose this option the Floor should be made 15mm smaller than Base Size No...

Страница 11: ...in most environments The surface must be dry and free of dirt oil grease and other contaminants prior to painting but no weathering of the surface is required Zinc rich primers are recommended for us...

Страница 12: ...nd very severe environmental situations or in any area where the mild steel corrosion rate as published by BRANZ exceeds 200g m2 3 Minimum maintenance must be carried out in accordance with instructio...

Отзывы: