14
230VAC
DMX 512 communication
Single PLP-REM-300 unit
1) Make sure DIP switch 1 is switched OFF.
2) Make sure the lights are turned ON with the remote first.
Address dial
Address dial setup
Setting the DMX address of the PLP-REM-300:
Select the desired number on the address dial. The chosen number deter-
mines the DMX addresses of the PLP-REM-300 & lamps.
Each lamp uses 3 bytes of DMX data (R-G-B), and all lamps receive the same
DMX data from the PLP-REM-300.
Connect DMX
panel
to DMX IN (+/-)
DMX PANEL
The DMX start address can be overruled by using the RS-485 command:
“set DMX start address” (see page 17)
DMX
address
1
2
3
4
5
6
7
8
9
...
0
1
2
...
R
G
B
R
G
B
R
G
B
...
Address dial
position