Duratech DLC-010 Скачать руководство пользователя страница 8

15

14

MODE

STATUS LED

COVER MOVEMENT

FILTERPUMP

NORMAL

(calibrated)

Green

Automatic or DMS*

Disabled when cover 
is not at end position

CALIBRATION

Green blinking slow

DMS

Disabled

FORCE

Yellow

DMS, open and close 

position temporary 

removed

Disabled

NOT CALIBRATED

Blue

DMS

Disabled when cover 

is moving

TEMPORARY ERROR

Red

DMS or no movement, 

depending on error 

condition

Active

FATAL ERROR

Red blinking fast

No movement 

possible

Active

Operation Modes

NORMAL (Calibrated)

Status LED is green

• 

The end points are programmed and the cover will not go outside these  

limits. 

• 

The cover can be controlled locally (via the key switch) and remote (via 

the LINKTouch), this in automatic mode and in DMS mode.

• 

In automatic mode, a soft-start and soft-stop is active. The cover stops 

when the calibrated open or close position is reached. 

• 

When the key switch is turned to the open or close position (or the open 

or close button on the LINKTouch is pressed) during movement of the 

cover, the cover stops immediately as an emergency brake.

• 

In DMS mode, only the soft-start is active. The cover stops immediately 

when the key switch (or LINKTouch button) is released.

• 

When a LINKTouch is used, the cover indicates its position on the LINK-

Touch.

• 

The relay for filtration pump is enabled when the cover is not in the cali-

brated open or close position.

*DMS = Dead Man Switch mode

CALIBRATION

The status LED blinks green.

The cover can be controlled locally (via the key switch) and remote (via Link-
Touch), but only in DMS mode: the cover stops immediately when the con-
trol is released.
The calibration procedure is explained in detail in topic “Calibration” (page 8)  and  
“correction” (page 9)

FORCE

The status LED is yellow.

This mode can be used to temporarily overrule the open and/or close posi-
tions of the cover when it is already calibrated. The cover can be controlled 
locally (via the key switch) and remote (via LinkTouch), but only in DMS mode: 
the cover stops immediately when the control is released.

NOT CALIBRATED

The status LED is blue.

The cover can be controlled locally (via the key switch) and remote (via Link-
Touch), but only in DMS mode: the cover stops immediately when the con-
trol is released.

TEMPORARY ERROR

The status LED is red.

The device indicates that an error is present. As soon as the error condition 
disappears, the device continues in normal operation.

Possible error conditions are listed in the Troubleshooting topic below.
In case an temporary error occurs: shut down the device and restart. If the 
error condition is not resolved, please contact your installer.

FATAL ERROR

The status LED is blinking red fast

The device shows a fatal error and cannot recover. Please contact your in-
staller.

Содержание DLC-010

Страница 1: ...DLC 010 Manual LINK Cover 09 05 22...

Страница 2: ...n Correction Dead Man Switch settings DLC 010 in combination with LinkTouch PLP REM 350 Installation instructions Calibration Dead Man Switch settings Operation Modes Normal Calibration Force Not Cali...

Страница 3: ...as following functionalities Programmable open and close positions Local control via key switch and or remote control via LinkTouch PLP REM 350 Dead man switch mode DMS can be set to open the cover an...

Страница 4: ...e right position termination re sistor ON CALIBRATION slide switch To calibrate the open and close position of the cover Switch needs to be ON to activate calibration FORCE slide switch Enables the co...

Страница 5: ...the key switch and check if the motor is rotating the correct way keyswitch turned to open cover needs to open If this is not the case then swap the motor power cables see picture next page switch th...

Страница 6: ...g the full calibration process This function is only possible if a cali bration was already done before When the open position is corrected the close position is changed accord ingly and the other way...

Страница 7: ...ON 1 Touch the display on the LinkTouch for 3 seconds to go into the settings menu 2 Use the right arrow key to select PLP REM enter then touch the display to confirm 3 In the next menu make sure the...

Страница 8: ...filtration pump is enabled when the cover is not in the cali brated open or close position DMS Dead Man Switch mode CALIBRATION The status LED blinks green The cover can be controlled locally via the...

Страница 9: ...ibration or calibration correction Cover moves in the wrong direction Swap the 2 motor connections or swap motor control via LinkTouch settings menu Cover settings Calibration failed Check the motor s...