Trouble shooting

Number

1

2

3

4

Indicator light for 

powersupply not 

working

Indicator light for

function is not 

working

Infrared Heater not 

heating up

Odor from the sauna

The connector is not 

connected properly

No power supply input

Indicator light is broken

The heating indicator light is 

broken

The circuit board or components 

are broken

The temperature sensor is broken

The heater is broken

The wire junction or the heater’s 

wire is loosen

The temperature sensor is broken

The circuit board of the relay is 

not working

The circuit‘s problems

Replace the circuit board

1)  There is a plastic bag around, 

       remove it.

2)

Some heater’s temperature

      too high, turn off the power

      supply and replace it.

3)  Parts on the circuitry are
       broken.

Check if junction of the 

temperature sensor is loose

and replace it

Check and make sure they are
tight 

Replace with a new one

of the same specifications

Check if the connection is loose 

and replace it

Replace the circuit board

Replace the relevant control 

panel

Check the connection or 

replace a new one

Check the circuitry ( especially

 whether there is power supply 

 input) 

Replace the circuitry panel

Problems

Possible reasons

Solutions

General content

Содержание FRB-2F3

Страница 1: ...Wooden Infrared Sauna User Guide and Instruction Manual FRB 2F3 WARNING Read all instructions carefully before using this sauna This product should always be used with care ...

Страница 2: ......

Страница 3: ...tents Important safety guides 1 Structure of infrared sauna 2 Installation process 3 Installation precautions 4 Control panel operation 5 Control box 7 Maintenance 8 Trouble shooting 9 Customer Support 11 ...

Страница 4: ...ure environment 11 Use caution when drinking alcohol 12 Avoid using if you have hemophilia or are prone to bleeding 13 Please consult with your doctor before using if you have health con cerns and or taking prescribed medicine 14 Do not use immediately after intense exercise wait until the body s core temperature returns to normal before use 15 If you feel any discomfort stop using the sauna immed...

Страница 5: ...dle 1 2 3 4 Control box Duster cover 5 Temperature sensor Topboard Backboard Heater frame 11 12 Right board 13 14 15 Door glass 10Ventilation 6 8 9 7 Front board Foot rest board Bench front board Bench Bottom board 16 17 18 19 1 2 3 4 5 6 7 8 9 10 11 12 13 14 16 15 17 18 19 ...

Страница 6: ...Installation process Back board Left board Bench Bench front board Bottom board Right board Top board Front board Foot rest board 3 ...

Страница 7: ...Installation precautions Large plate assembly Outer buckle installation method 4 Electrical connection 1 2 Conection cable Connection plug ...

Страница 8: ...imes when there is 5 minutes left See the next page for details Audio function See the next page for details Power lock function Press and hold LOCK button for 5S when the indicator light turns on the display is now locked To unlock press and hold LOCK button for 5S indicator light will turn off Timer display Displays timer USB function Touch this key to start USB function Power button Touch this ...

Страница 9: ...tion While radio is on press and hold AUDIO button it will search for frequencies automatically The frequency range is 87 5MHZ 108MHZ when search the effective signal frequency it will save it Using the system for the first time you will need to scan for the local channels 4 Press the forth time turn off sound function Light button On the status of system standby press LIGHT button to turn on or tu...

Страница 10: ...A LOAD F Main power of sauna room Fuse reset Lamp power output cable 12V output Control panel connecting Antenna USB output Color lamp power output Audio output Temperature sensor connection port 1 2 3 4 5 5 L A M P A B L O A D C L O A D D L O A D E L O A D F L O A D 4 1 2 3 L A M P A L O A D C L O A D D L O A D E L O A D F L O A D B L O A D A C P O W E R L N O C P ...

Страница 11: ...acuum cleaner 2 Do not use organic solvents to clean surfaces such as gasoline alcohol etc wipe the sauna surface 3 Do not use sharp objects in sauna cabin to prevent scratching woods Stain on glass 1 Clean the glass with soft materials 2 Stubborn stains can be wiped with a damp cloth then dry with a dry cloth 3 Do not scratch the surface with a sharp object to prevent scratching the glass Transpo...

Страница 12: ...t board of the relay is not working The circuit s problems Replace the circuit board 1 There is a plastic bag around remove it 2 Some heater s temperature too high turn off the power supply and replace it 3 Parts on the circuitry are broken Check if junction of the temperature sensor is loose and replace it Check and make sure they are tight Replace with a new one of the same specifications Check i...

Страница 13: ...lace the display panel Replace a new CPU No power input Check for power Reconnect the control computer cable Replace the temperature sensor Disconnect the paired device Check if the Bluetooth version is compatible The system supports version 2 0 or 4 0 Use device with matcing version Replace the 4 in 1 audio module Excessive temperature Sensor short circuit The system has overload overcurrent prot...

Страница 14: ...isted below the Limited Warranty Period One Year Limited Warranty Period One and a half Year 1 5 from original purchase date All Electronic Durasage Products unless otherwise stated During the Warranty Period Durasage will repair replace at no charge products or parts of a product that proves defective because of improper material or workmanship under normal use and maintenance What does this limi...

Отзывы: