Durand Interstellar, Inc. Switch-4 Скачать руководство пользователя страница 10

Customizing the Switch-4

You may order the Switch-4 customized in several ways, contact us for details.

Items that can be customized

No enclosure or different enclosure

Switches mounted on the enclosure

MIDI or RS-232 output

Baud rate for RS-232

Debounce time (0-65mS in 4mS steps)

Data sent for each switch action. 

For MIDI this may be any string of hex data, notes, controls, MIDI 
Show Control, etc.

For RS-232 this may be any string of 8-bit data except null (zero).

Data strings may be reused, for example the same string can be 
used for all Switch Off strings.

The total space for all strings combined is 168 characters (text 
characters or MIDI bytes). If all strings are the same length that's 
21 characters per string.

Any strings may be null (nothing sent).

For a small additional fee you can have an extended version of the 
Switch-4 with about 1,400 characters of storage. Check with us for 
the latest options.

Other customization possibilities exist such as precision delays and other 
timer functions, counters (resettable or non-resettable), different actions 
depending on how long a switch is held, and others. We can also supply 
full custom units with many more inputs, other outputs, whatever you may 
need.

Содержание Switch-4

Страница 1: ...nd RS 232 Versions PC Board Revision 1 January 14 2011 Instruction Manual Durand Interstellar Inc 219 Oak Wood Way Los Gatos California 95032 2523 www interstellar com tel 1 408 356 3886 USA toll free...

Страница 2: ...ble of Contents Table of Contents i Intended Use 1 Specifications 2 Mounting 3 Wire Connections 4 Testing 6 Standard Commands 7 Customizing the Switch 4 8 California Proposition 65 Warning 9 Warranty...

Страница 3: ...all energy conservation requirements This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this...

Страница 4: ...unce 20mS on both Open and Close Initial Delay Switches are ignored for about 5 seconds after power up Data output MIDI Note commands RS 232 characters or customized Output Levels 0V and 5V current li...

Страница 5: ...inals J1 in the illustration below should be on the bottom This lets the wires hang freely and also prevents any foreign material from falling in through the slot in the box J2 is only used for initia...

Страница 6: ...rge switches intended for high current may be electrically noisy and may need a capacitor across them to prevent multiple detections Contact us if you need any help with switches If using solid state...

Страница 7: ...pin your equipment expects to receive data on If you have any other pins possibilities are DCD DTR DSR RTS CTS RI that need to be held at Space for your application connect them to the D terminal All...

Страница 8: ...e at a time operate each switch note that the Status LED blinks off once for each time any switch changes state once for opening and once for closing If you see multiple blinks instead of just one it...

Страница 9: ...0x40 Switch 3 ON sends Note 3 On Velocity 64 0x90 0x03 0x40 Switch 3 OFF sends Note 3 Off Velocity 64 0x80 0x03 0x40 Switch 4 ON sends Note 4 On Velocity 64 0x90 0x04 0x40 Switch 4 OFF sends Note 4 O...

Страница 10: ...e the same string can be used for all Switch Off strings The total space for all strings combined is 168 characters text characters or MIDI bytes If all strings are the same length that s 21 character...

Страница 11: ...re even trace amounts of the chemicals included on Proposition 65 s list of chemicals known to the State of California to cause cancer or reproductive toxicity must be noted with the Safe Harbor wordi...

Страница 12: ...on caused by customer abuse misuse negligence or failure to follow operating instructions Ordinary adjustments to the product which can be performed by the customer as outlined in the instruction manu...

Отзывы: