background image

 

 

180 DS 

 

duralloy.net.au 

 

 

 

1. Safety 

Welding  may  damage  your  body  or  others,  so  please  take  protection  measure  in 
operation. 

Only ones who are trained professionally can install, operate, maintain and 
repair the equipment. 
Do not maintain and repair the machine when the machine is connected with 
power. 
Electric shock can kill. 
Never touch electrical parts. 
Wear dry, hole-free gloves and clothes to insulate yourself. 
Insulate yourself from work and ground using dry insulation. Make certain the 
insulation is large enough to cover your full area of physical contact with work 
and ground. 
Ensure to install the equipment correctly and ground the work or metal to be 
welded to a good electrical (earth) ground according the operation manual. 
Ensure to operate the equipment in safe position. 
Fumes and gasses can be dangerous! 
Welding may produce fumes and gases hazardous to health. Avoid breathing 
these fumes and gases. When welding, keep your head out the fume. 
Using enough ventilation and/or exhaust at the arc to keep fumes and gases 
away from the breathing zone. 
Welding sparks can cause fire or explosion. 
Remove fire hazards from the welding area. If this is not possible, cover them 
to prevent the welding sparks from starting a fire. Remember that welding 
sparks and not materials from welding can easily go through small cracks and 
openings to adjacent areas. 
Do not weld enclosed tanks or containers. 
Prohibit to use welder to unfrozen. 
Have a fire extinguisher readily available. 
Hot parts can lead to burn. 
Do not touch the hot parts. 
Please use the torch after cooling or use the welding blow lamp. 
The people with heart-pacemaker should be away from the welding arc. 
Rotating parts may be dangerous. 
Far away from rotating parts. (Like fan) 
Keep the parts of machine in the safe position. 

Содержание 180DS

Страница 1: ...duralloy net au 180DS OPERATION MANUAL Part No DA180DS ...

Страница 2: ...l principle drawing 5 4 Parameters 5 5 Operation control and connectors 6 6 Installation Adjustment 7 6 1 Installation 7 6 2 Operation 7 6 3 Welding Table 7 7 Operation Notices 8 7 1 Installation 8 7 2 Safety 8 8 Maintenance 9 9 Troubleshooting Service 10 10 WARRANTY 11 ...

Страница 3: ...d gasses can be dangerous Welding may produce fumes and gases hazardous to health Avoid breathing these fumes and gases When welding keep your head out the fume Using enough ventilation and or exhaust at the arc to keep fumes and gases away from the breathing zone Welding sparks can cause fire or explosion Remove fire hazards from the welding area If this is not possible cover them to prevent the ...

Страница 4: ...ctuation to the current There are also some automatic protection functions for under voltage over current over heat etc inside the welders when the problems listed before occurred the alarm on the front panel is light and at the same time the output current will be cut off It can self protect and prolong the using life and greatly improved the reliability of the welders 180DS can be used easily al...

Страница 5: ...Current A 15 34A Duty Cycle 40 10min 20 180A 60 104A 100 80A No Load Voltage V 84 Welding Current Range A 10 180 Efficiency 85 Power Factor 0 76 Net Weight Kg 3 2 Protection Class IP21s Insulation Class F Dimensions mm 265 120 218 Electrode Diameter φ1 6 φ4 0 Electrode Type 6013 7018 etc Circuit Schematic of INARC Welder Figures for reference are subject to change without notice ...

Страница 6: ...is terminal 2 Positive Output terminal For MMA welding plug Arc Lead into this terminal For TIG Welding plug Earth Lead into this terminal 3 Mode Selector Button MMA MMA VRD TIG 4 Current digital display 5 Thermal overload light This is illuminated if the machine overheats 6 Amperage adjustment knob 7 VRD Warning light 8 Power Access client Primary power Lead 9 On Off Switch ...

Страница 7: ...welding rod to choose DCSP method In general the basic electrode reverse method is recommended ie connected to the positive electrode 6 2 Operation 1 To operate the machine turn the power switch so that the power switch is in the ON position then the power indicator light fan comes on the device is ready to use 2 Please note choose correct polarity selection based on the electrodes to be used 3 En...

Страница 8: ...ure protection circuit when the primary voltage output current and the internal temperature exceeds the set temperature the welding machine will automatically stop working so you need to note the following 1 To ensure good ventilation The machine is equipped with internal cooling fan ensure that there is adequate air flow around the machine 2 Do not exceed duty Cycle Operators should ensure to use...

Страница 9: ...low hands hair and tools near live components inside the machine such as fans so as not to hurt or cause damage to the person or machine 3 Regularly with a clean dry compressed air to clean dust from the machine compressed air pressure should be at reasonable levels in order to avoid damage to the welding components inside 4 Avoid water or water vapor entering into the welding machine if there is ...

Страница 10: ...put 1 The current potential is damaged should be replaced 2 faulty connections such as lead plugs to be checked Power indicator light on fan operating with no welding output 1 Check all connections inside the machine circuit output connections is faulty 2 the alarm indicator light 1 that access to protected status because of overheating in which case To maintain power so that the temperature dropp...

Страница 11: ...Torches 3 months TIG Torches 3 months Plasma Torches 3 months Ancillary Equipment 3 months The Obligation of Duralloy Industrial Supply under this warranty is limited to the circumstance set out above and is subject to The customer being able to provide proof of purchase of the relevant equipment A defect in either material or workmanship The customer returning the product to Duralloy Industrial s...

Отзывы: