background image

SPECIFICATIONS

MODEL 

PPS1000-1050-120-01

BATTERY
Chemistry Li-Ion
Maximum Capacity 

1050Wh ([email protected])

Lifecycles 

500 Cycles to 80% capacity

Storage Requirement 

Recharge every 3-6 months

Protection Systems* 

Over & Under Temperature Protection,

   

Short Circuit Protection, Overload Protection,

   

Battery Over Charge and Over Discharge 

   

Protection, DC Input Reverse

   

Polarity Protection. 

PORTS 
2x USB-A Port (Output) 

5V @ 2.4A per port

2x USB-A Fast Charge Port (Output) 

5V@3A, 9V@ 2A, [email protected] 18W Max per port

USB-C Port (Input/Output) 

100W Maximum

USB-C Port (Output) 

27W

3x 120V AC Port (Output, Pure Sine Wave) 

120V, 60Hz (1000W continuous, 2000W Peak)

13V Cigarette Lighter Port (Output) 

13V up to 10A

2x DC Port (Output) 

13V up to 5A per port

DC Charging Port (Input) 

12-30V @6.5A (195W Maximum) DC F6530

  

connector

Solar Charger Anderson Port 

12-30V @ 6.5A (195Wp Maximum)

CHARGE TIME 
Wall Charger (120W Charger) 

10-11Hrs

Solar Panels 

12-13Hrs

Car Charger 

21-24Hrs(12V) 10-12Hrs(24V)

Type C 100W PD charging 

12-13Hrs

Wall Charger (120W Charger) + Type C 100W  

5-6Hrs

GENERAL 
Dimensions 

13.38*9.29*8.11in (34*23.6*20.6cm)

Weight 

24.6lbs (11.15Kg)

Operating Temperature  

32-104˚F (0-40˚C)

Storage Temperature 

42-85˚F (6-29˚C)

Certifications FCC/DOE/CEC/ETL/RoHS
Warranty 

24 Months

The Unit will have the following protection alarms:
Beeps 2 times: Overload protection, shuts down the port.
Beeps 5 times: Over temperature protection, shuts down AC port.
Beeps 7 times: Battery UVP (Once at 5% SOC and again at 0% SOC).
Beeps 8 times: Short circuit protection, shuts down the port.
Beeps 9 times: No load shutdown, Unit shutdown normally. 
Beeps 10 times: Abnormal communication between the master controller of the Unit and Inverter, AC icon will 
blink and the AC port will shut down.
Beeps 11 Times: Battery related faults. Unit shuts down any charge and discharge. 

*

Содержание POWER 1000

Страница 1: ...POWER 1000 USER MANUAL...

Страница 2: ...ed Duracell accessories and chargers 5 Do not expose the Unit to fire or excessive temperature Any such exposure to fire or temperature above 140 F 60 C may cause an explosion Do not use near flammabl...

Страница 3: ...e Remaining Run Time Charge Time Total input or output power DC port ON USB port ON IN OUT USB C port ON AC port ON Fan icon indicates that Fan is ON Overload warning Inverter over temperature warning...

Страница 4: ...r connect the provided car charger cable to your vehicle s 12V socket cigarette lighter port and to the Unit s DC Input Port Car Charger Cable provided with the Unit is to be used only for charging th...

Страница 5: ...imit is exceeded the Unit will shut OFF automatically 6 The AC port output will turn OFF automatically after 2 hours if no load is detected 7 The DC port or car charger port will turn OFF automaticall...

Страница 6: ...This means that the load connected exceeds the power rating of the AC port 1000W Disconnect your device from the Unit turn the port ON again and try connecting a device that doesn t exceed the power r...

Страница 7: ...oad 4 How to store my Power 1000 Before storing please turn off the Unit first and then store it in a dry ventilated place at room temperature 42 85 F Do not place it near water sources For long term...

Страница 8: ...is not liable for financial damages lost profits claims from third parties etc arising from the use of this product For more information regarding our product line customer service and warranty inform...

Страница 9: ...Anderson Port 12 30V 6 5A 195Wp Maximum CHARGE TIME Wall Charger 120W Charger 10 11Hrs Solar Panels 12 13Hrs Car Charger 21 24Hrs 12V 10 12Hrs 24V Type C 100W PD charging 12 13Hrs Wall Charger 120W Ch...

Отзывы: