Durabrand T6609BK Скачать руководство пользователя страница 5

1-2-1

TVVCRP_ISP

IMPORTANT SAFETY PRECAUTIONS

Prior to shipment from the factory, our products are strictly inspected for recognized product safety and electrical 
codes of the countries in which they are to be sold. However, in order to maintain such compliance, it is equally 
important to implement the following precautions when a set is being serviced. 

Safety Precautions for TV Circuit

1. Before returning an instrument to the 

customer,

 always make a safety check of the 

entire instrument, including, but not limited to, the 
following items:

a.

Be sure that no built-in protective devices are 
defective and have been defeated during 
servicing. (1) Protective shields are provided 
on this chassis to protect both the technician 
and the customer. Correctly replace all missing 
protective shields, including any removed for 
servicing convenience. (2) When reinstalling 
the chassis and/or other assembly in the 
cabinet, be sure to put back in place all 
protective devices, including but not limited to, 
nonmetallic control knobs, insulating 
fishpapers, adjustment and compartment 
covers/shields, and isolation resistor/capacitor 
networks. 

Do not operate this instrument or 

permit it to be operated without all 
protective devices correctly installed and 
functioning. Servicers who defeat safety 
features or fail to perform safety checks 
may be liable for any resulting damage.

b.

Be sure that there are no cabinet openings 
through which an adult or child might be able to 
insert their fingers and contact a hazardous 
voltage. Such openings include, but are not 
limited to, (1) spacing between the picture tube 
and the cabinet mask, (2) excessively wide 
cabinet ventilation slots, and (3) an improperly 
fitted and/or incorrectly secured cabinet back 
cover.

c. Antenna Cold Check -

 With the instrument AC 

plug removed from any AC source, connect an 
electrical jumper across the two AC plug 
prongs. Place the instrument AC switch in the 
on position. Connect one lead of an ohmmeter 
to the AC plug prongs tied together and touch 
the other ohmmeter lead in turn to each tuner 
antenna input exposed terminal screw and, if 
applicable, to the coaxial connector. If the 
measured resistance is less than 1.0 megohm 
or greater than 5.2 megohm, an abnormality 
exists that must be corrected before the 
instrument is returned to the customer. Repeat 
this test with the instrument AC switch in the off 
position.

d. Leakage Current Hot Check -

 With the 

instrument completely reassembled, plug the 
AC line cord directly into a 120 V AC outlet. (Do 
not use an isolation transformer during this 
test.) Use a leakage current tester or a 
metering system that complies with American 
National Standards Institute (ANSI) C101.1 

Leakage Current for Appliances and 
Underwriters Laboratories (UL) 1410, (50.7). 
With the instrument AC switch first in the on 
position and then in the off position, measure 
from a known earth ground (metal water pipe, 
conduit, etc.) to all exposed metal parts of the 
instrument (antennas, handle brackets, metal 
cabinet, screw heads, metallic overlays, control 
shafts, etc.), especially any exposed metal 
parts that offer an electrical return path to the 
chassis. Any current measured must not 
exceed 0.5 milli-ampere. Reverse the 
instrument power cord plug in the outlet and 
repeat the test.

ANY MEASUREMENTS NOT WITHIN THE 
LIMITS SPECIFIED HEREIN INDICATE A 
POTENTIAL SHOCK HAZARD THAT MUST 
BE ELIMINATED BEFORE RETURNING THE 
INSTRUMENT TO THE CUSTOMER OR 
BEFORE CONNECTING THE ANTENNA OR 
ACCESSORIES.

e. X-Radiation and High Voltage Limits -

 

Because the picture tube is the primary 
potential source of X-radiation in solid-state TV 
receivers, it is specially constructed to prohibit 
X-radiation emissions. For continued 
X-radiation protection, the replacement picture 
tube must be the same type as the original. 
Also, because the picture tube shields and 
mounting hardware perform an X-radiation 
protection function, they must be correctly in 
place. High voltage must be measured each 
time servicing is performed that involves B+, 
horizontal deflection or high voltage. Correct 
operation of the X-radiation protection circuits 
also must be reconfirmed each time they are 
serviced. (X-radiation protection circuits also 

ALSO TEST WITH
PLUG REVERSED
USING AC
ADAPTER PLUG
AS REQUIRED

TEST ALL EXPOSED
METAL SURFACES

READING SHOULD 
NOT BE ABOVE 0.5 mA

EARTH
GROUND

_

DEVICE

LEAKAGE

CURRENT

TESTER

+

BEING

TESTED

Содержание T6609BK

Страница 1: ...tion for Servicing I Adjustment Procedures I Schematic Diagrams I CBA s I Exploded Views I Parts List When servicing the deck mechanism refer to MK14 Deck Mechanism Section Deck Mechanism Part No N232...

Страница 2: ...e TV VCR Combination 1 7 1 Mechanical Trouble Indicator 1 8 1 Block Diagrams 1 9 1 Schematic Diagrams CBA s and Test Points 1 10 1 Waveforms 1 11 1 Wiring Diagram 1 12 1 System Control Timing Charts 1...

Страница 3: ...arity Horizontal 15 Vertical 10 3 High Voltage kV 22 Description Condition Unit Nominal Limit 1 Misconvergence Center m m 0 6 Corner m m 2 0 Side m m 1 5 2 Contrast Control Range dB 6 3 Brightness APL...

Страница 4: ...tion that still might be considered acceptable In no case should a unit fail to meet limit specifications TV NORM TUNER SENSIVITY RECEPTIVE TV CHANNELS Description Condition Unit Nominal Limit 1 Audio...

Страница 5: ...crew and if applicable to the coaxial connector If the measured resistance is less than 1 0 megohm or greater than 5 2 megohm an abnormality exists that must be corrected before the instrument is retu...

Страница 6: ...he voltage potential between the chassis and a known earth ground b Some TV receiver chassis normally have 85V AC RMS between chassis and earth ground regardless of the AC plug polarity This chassis c...

Страница 7: ...e that foreign objects screws solder droplets etc do not remain inside the set K Crimp type wire connector When replacing the power transformer in sets where the connections between the power cord and...

Страница 8: ...rnally exposed accessible parts RF terminals antenna terminals video and audio input and output terminals microphone jacks earphone jacks etc Measuring Method Power ON Insert load Z between B earth gr...

Страница 9: ...uld be inserted parallel into the connector not at an angle How to Read the Values of the Rectangular Type Chip Components Example a Resistor b Capacitor Caution Once chip parts Resistors Capacitors T...

Страница 10: ...tallation 130 C 150 C for about two minutes Note a Leadless components must not be reused after removal b Excessive mechanical stress and rubbing for the component electrode must be avoided 2 Removing...

Страница 11: ...ift each lead of the flat pack IC upward one by one using a sharp pin or wire to which solder will not adhere iron wire When heating the pins use a fine tip soldering iron or a hot air desoldering mac...

Страница 12: ...ark on the flat pack IC indicates pin 1 See Fig S 1 7 Be sure this mark matches the 1 on the PCB when positioning for installation Then presolder the four corners of the flat pack IC See Fig S 1 8 3 S...

Страница 13: ...ded to remove any static electricity that may be charged on the body 2 Ground for Workbench Be sure to place a conductive sheet or copper plate with proper grounding 1 M on the workbench or other surf...

Страница 14: ...his switch can not be operated automatically Preparing 2 1 To eject the tape press the STOP EJECT button on the unit or Remote Control 2 When you want to record during the Service mode press the Rec b...

Страница 15: ...r Cabinet 2 CAUTION Discharge the Anode Lead of the CRT with the CRT Ground Wire before removing the Anode Cap Removal of the Power Unit and Tray Chassis Unit Discharge the Anode Lead of the CRT with...

Страница 16: ...ont 7 Removal of the Deck Unit Remove seven screws S 6 screw S 7 and screw S 8 Then desolder connectors CN201 CL401 CL402 CL403 and lift up the Deck Unit 8 Removal of the Main CBA Remove four screws S...

Страница 17: ...Power Unit and Tray Chassis Unit 5 H V Power Supply CBA S 3 S 3 3 Power Unit Power Button S 3 S 4 S 4 S 4 S 5 7 Bottom Plate CL604 S 4 S 6 S 9 S 9 S 9 S 9 S 6 S 6 S 6 8 Deck Unit 6 Top Cover 9 Main CB...

Страница 18: ...1 5 4 T6609DC S 10 S 10 S 10 S 10 Anode Cap 10 CRT CRT CBA Fig D4...

Страница 19: ...SEMBLY ACE HEAD ASSEMBLY CAPSTAN MOTOR DECK UNIT CN201 CL402 CL401 CL403 CL302A CL603A CL301A MAIN CBA CN501 SCREEN FOCUS CN502 CN501B CL501A CN601 CN552 CN551 CN602 CRT ANODE GND H V POWER SUPPLY CBA...

Страница 20: ...c Tip Driver 9 RF input at each broadcasting system Receiving Channel VHF Low Input level 80dB V 10 Ext input FRONT VIDEO IN JACK or REAR SCART JACK How to Set up the Service mode Note After replacing...

Страница 21: ...of screen image may not be properly displayed Note R590 H V Power Supply CBA 1 Connect Frequency Counter to R590 2 Set the unit to the Ext mode and no input is necessary Enter the Service mode See pa...

Страница 22: ...grayscale compared with PAL signal Note J361G4 Main CBA 1 Degauss the CRT and allow CRT to operate for 20 minutes before starting the alignment 2 Input the SECAM Gray Scale signal from Ext input 3 En...

Страница 23: ...ay will change to V P and V S 2 Input monoscope pattern and leave it for at least 20 minutes 3 Press PROG PROG buttons on the remote control unit so that the top and bottom of the monoscope pattern ar...

Страница 24: ...green and blue beams correctly for pure white Symptom of Misadjustment White becomes bluish or reddish Note Use remote control unit 1 Operate the unit more than 20 minutes 2 Face the unit to east Dega...

Страница 25: ...ressed display will change BRT CNT COL TNT and SHP in that order CONTRAST CNT 1 Press MENU button on the remote control unit Then select CNT display 2 Press PROG PROG buttons on the remote control uni...

Страница 26: ...will display on the screen if adjustment is necessary follow step 4 7 0H 448 s is preferable 5 Press PROG PROG buttons on the remote control unit if necessary The value will be changed in 0 5H steps...

Страница 27: ...and MUTE buttons on the remote control unit in that order within 5 seconds To cancel the Service mode press STANDBY ON button on the remote control 3 Press SLEEP button on the remote control unit to...

Страница 28: ...r Malfunction 1 and immediately turn OFF the POWER MONITOR and switch over the Mechanical Malfunction mode with POWER OFF To return from this mode shall become possible only by POWER Key as in the cas...

Страница 29: ...the function according to its mode 4 Countermeasure for CASSETTE LOADING Malfunction a CASSETTE IN operating Malfunction If LD SW does not go to SB position after a lapse of 5 sec or more from the CA...

Страница 30: ...TY TO VIDEO BLOCK TO AUDIO BLOCK KEY SWITCH KEY SWITCH SW201 SW205 SCL MEMORY SDA 6 5 REC LED 24 REC LED 23 P DOWN L 85 P ON H P DOWN L P ON H 67 D202 REC AL 5V LD SW 9 I 2 C OPEN 45 71 AL 5V SW212 LD...

Страница 31: ...IDEO AUDIO SIGNAL PROCESS REC VIDEO SIGNAL PB VIDEO SIGNAL MODE SP REC SERIAL DECORDER 48 52 54 56 61 63 96 95 93 94 CHARA INS CCD 1H DELAY BYPASS MUTE PB EE TUNER TUNER MUTE PB EE LINE SCART LINE SCA...

Страница 32: ...FE H 2 FE H GND CL403 MAIN CBA PB AUDIO SIGNAL REC AUDIO SIGNAL Mode SP REC 71 A MUTE H SCL SDA TO SERVO SYSTEM CONTROL BLOCK TO SERVO SYSTEM CONTROL BLOCK FULL ERASE HEAD 68 69 SERIAL DECODER DECK AS...

Страница 33: ...WF11 CN303 NO CONNECTION CN303 is used for adjustment at factory I 2 C OPEN 3 FBP 2 H DRIVE 1 ACL 5 V RAMP FB 4 V DRIVE 3 MAIN CBA 32 21 17 12 13 30 28 20 27 11 10 14 31 15 16 6 7 43 36 VIDEO 34 CHROM...

Страница 34: ...501 CRT GND FOCUS SCREEN JK501 HEATER 1 1 CN501 CL501B CL501A REC VIDEO SIGNAL PB VIDEO SIGNAL CN551 P ON 160V 3 3 TO TV BLOCK CL302A 11 S F HV FOCUS VR SCREEN VR B TO POWER SUPPLY BLOCK DEF B H OUTPU...

Страница 35: ...CN602 12 JUNCTION A CBA H V POWER SUPPLY CBA CL603B CN603 P ON H TO PIN67 OF IC201 5V REG 5V REG 5V REG IC681 Q684 Q686 P ON 5V 1 P ON 5V 3 P ON 5V 2 AL 33V CM 12V CL603A 12 5 4 6 3 7 8 11 12 5 4 6 3...

Страница 36: ...k in the schematic diagram and the parts list Before replacing any of these components read the parts list in this manual carefully The use of substitute replacement parts that do not have the same sa...

Страница 37: ...n original function and reliability of repaired units use only original replacement parts which are listed with their part numbers in the parts list section of the service manual 4 Mode SP REC 5 Volta...

Страница 38: ...1 10 3 T6609SCM1 Main 1 5 Sensor Schematic Diagram...

Страница 39: ...1 10 4 T6609SCM2 Main 2 5 Schematic Diagram...

Страница 40: ...1 10 5 T6609SCM3 Main 3 5 Schematic Diagram...

Страница 41: ...1 10 6 T6609SCM4 Main 4 5 Schematic Diagram...

Страница 42: ...1 10 7 T6609SCM5 Main 5 5 Schematic Diagram...

Страница 43: ...TION For continued protection against fire hazard replace only with the same type fuse CAUTION Fixed voltage or Auto voltage selectable power supply circuit is used in this unit If Main Fuse F601 is b...

Страница 44: ...1 10 9 H V Power Supply 2 2 Junction B Schematic Diagram T6609SCP2...

Страница 45: ...1 10 10 CRT Junction C Schematic Diagram T6609SCCRT...

Страница 46: ...OR CBA START SENSOR CTL TP001 RF SW TP002 WF3 WF1 N A PB TP007 WF8 J361G4 SECAM Black Level Adjustment C PB TP008 WF6 V OUT TP003 WF5 J349F3 C Trap Adjustment Main CBA Top View BT6600F01014 Sensor CBA...

Страница 47: ...10 12 PIN 52 OF IC301 WF7 PIN 13 OF IC301 WF10 PIN 8 OF IC401 WF9 PIN 58 OF IC201 WF17 PIN 29 OF IC401 PIN 59 OF IC201 WF18 PIN 7 OF IC301 WF11 WF2 PIN 48 OF IC401 WF4 Main CBA Bottom View BT6600F0101...

Страница 48: ...lation transformer is required NOTE The voltage for parts in hot circuit is measured using hot GND as a common terminal CAUTION For continued protection against fire hazard replace only with the same...

Страница 49: ...tion transformer is required NOTE The voltage for parts in hot circuit is measured using hot GND as a common terminal CAUTION For continued protection against fire hazard replace only with the same ty...

Страница 50: ...1 10 15 WF14 Q501 Collector WF15 Q502 Collector WF16 Q503 Collector CRT CBA Top View CRT CBA Bottom View BT6600F01022 B...

Страница 51: ...1 10 16 Junction A CBA Top View BT6600F01014 Junction A CBA Bottom View Junction B CBA Top View Junction B CBA Bottom View Junction C CBA Top View Junction C CBA Bottom View...

Страница 52: ...1DIV 0 5V 20 s TP003 V OUT Upper WF6 Lower WF1 1DIV 0 2V 2DIV 5V 5ms TP008 C PB WF7 1DIV 0 2V 0 5ms IC301 PIN 52 WF8 1DIV 0 5V 0 5ms TP007 N A PB WF9 1DIV 0 5V 0 5ms IC401 PIN 8 WF10 1DIV 2V 5ms IC30...

Страница 53: ...CBA CN502 H V POWER SUPPLY CBA SENSOR CBA END SENSOR SENSOR CBA ST SENSOR 3 V L V COM 2 V R 1 VG 12 AL 12V 1 11 M GND 10 D PFG 9 D CONT 8 LD CONT 7 FG GND 6 C CONT 5 C F R 4 3 C FG P ON 5V 3 2 1 CM 1...

Страница 54: ...LD REV 0 2S 0 5S PIN NO CL EJ SS SS AU AU TL LD SW CL SS LD CONT C DRIVE Z ON ON C F R DRUM ROTATION P ON A MUTE H D REC H D PB H PAUSE ON PAUSE PAUSE ON PAUSE OFF PAUSE OFF AU AL AU SF SM EJ AU RS S...

Страница 55: ...P A LD REV FF LD REV LD REV LD FWD LD FWD LD FWD LD FWD LD FWD LD FWD LD FWD REC PAUSE REC REC REW LD REV LD REV LD REV LD REV LD REV LD REV LD REV PAUSE REC or PAUSE STOP EJECT STOP EJECT STOP EJECT...

Страница 56: ...sed 31 IN REC SAFETY Record Protection Tab Detection 32 NU Not Used 33 NU Not Used 34 IN RESET System Reset Signal Reset L 35 IN XCIN Sub Clock 32 kHz 36 OUT XCOUT Sub Clock 32 kHz 37 TIMER 5V Vcc 38...

Страница 57: ...L Teletext Control Signal 83 NU Not Used 84 NU Not Used 85 IN P DOWN L Power Voltage Down Detector Signal at Low 86 NU Not Used 87 IN C FG Capstan Motor Rotation Detection Pulse 88 AMPVss AMPVss GND 8...

Страница 58: ...1267 GR AT P KTA1271 Y KTC3198 GR AT P KTC3199 GR AT P MID 32A22F PT204 6B 12 2SA1346 2SC1815 GR TE2 F T 2SC2120 O TE2 F T 2SC2120 Y TE2 F T 2SC3331 T U KRA103M AT P KTA 1266 GR AT P KTC3203 Y AT P KT...

Страница 59: ...3 TB2 B10 SP151 CL801 1B1 A A L2 PB5 PB1 PB4 PL2 PL2 PL2 PL1 TB3 CL604 TB21 TB7 PL1 PL1 H V Power Supply CBA Sensor CBA CRT CBA Sensor CBA Main CBA Junction A CBA Junction C CBA Junction B CBA V501 CL...

Страница 60: ...1 16 2 T6609PEX Packing S3 S6 X3 S2 X4 Loop Antenna X1 TAPE TAPE S12 S1 FRONT S4 S5 Shipping Label IC Tag Label X2 X24...

Страница 61: ...AD GBUP4120 L8 FLAT HEAD SCREW T4000UA 0EM404793 L9 SCREW S TIGHT 3X4 BIND HEAD GBMS3040 L551 DEFLECTION YOKE LLBY00ZSY005 or LLBY00ZSY005 DEFLECTION YOKE KDY3GDA82X LLBY00ZMS011 SP151 SPEAKER S08F02B...

Страница 62: ...KMASTL331 C217 CHIP CERAMIC CAP 1608 CH D 10pF 50V or CHD1JD3CH100 CHIP CERAMIC CAP CH D 10pF 50V CHD1JDBCH100 C218 CHIP CERAMIC CAP 1608 CH D 10pF 50V or CHD1JD3CH100 CHIP CERAMIC CAP CH D 10pF 50V C...

Страница 63: ...ECTROLYTIC CAP 1 F 50V M or CE1JMASDL010 ELECTROLYTIC CAP 1 F 50V M or CE1JMASDL1R0 Ref No Description Part No ELECTROLYTIC CAP 1 F 50V M CE1JMASTL1R0 C322 ELECTROLYTIC CAP 470 F 10V M or CE1AMASDL471...

Страница 64: ...1 F 25V or CHD1EZ30F104 CHIP CERAMIC CAP F Z 0 1 F 50V or CHD1JZB0F104 CHIP CERAMIC CAP F Z 0 1 F 25V CHD1EZB0F104 C443 ELECTROLYTIC CAP 1 F 50V M H7 CE1JMAVSL1R0 Ref No Description Part No C444 CHIP...

Страница 65: ...or QDTZ001SS133 SWITCHING DIODE 1N4148 NDTZ001N4148 D402 CARBON RES 1 4W J 10k RCX4JATZ0103 D682 PCB JUMPER D0 6 P10 0 JW10 0T D686 SWITCHING DIODE 1SS133 T 77 or QDTZ001SS133 Ref No Description Part...

Страница 66: ...IN TRANSISTOR 2SA1346 or 2SA1346Z RES BUILT IN TRANSISTOR BN1F4M T QQSZ00BN1F4M Ref No Description Part No Q705 PCB JUMPER D0 6 P5 0 JW5 0T Q706 TRANSISTOR 2SC2785 F or QQSF02SC2785 TRANSISTOR 2SC278...

Страница 67: ...P RES 1608 1 10W 0 or RRXAZR5Z0000 CHIP RES 1608 1 10W 0 RRXAZB5Z0000 R235 CHIP RES 1608 1 10W J 1k or RRXAJR5Z0102 Ref No Description Part No CHIP RES 1608 1 10W J 1k RRXAJB5Z0102 R236 CHIP RES 1608...

Страница 68: ...AJB5Z0101 R334 CHIP RES 1608 1 10W J 100 or RRXAJR5Z0101 CHIP RES 1608 1 10W J 100 RRXAJB5Z0101 Ref No Description Part No R335 CARBON RES 1 4W J 100 RCX4JATZ0101 R336 CHIP RES 1608 1 10W J 10k or RRX...

Страница 69: ...0W J 6 2k RRXAJB5Z0622 R748 CHIP RES 1608 1 10W J 1 8k or RRXAJR5Z0182 CHIP RES 1608 1 10W J 1 8k RRXAJB5Z0182 Ref No Description Part No R749 CHIP RES 1608 1 10W J 10k or RRXAJR5Z0103 CHIP RES 1608 1...

Страница 70: ...5 JW12 5T TP007 PCB JUMPER D0 6 P10 0 JW10 0T TP008 PCB JUMPER D0 6 P12 5 JW12 5T TP009 PCB JUMPER D0 6 P12 5 JW12 5T TP010 PCB JUMPER D0 6 P22 5 JW22 5T TU001 TUNER UNIT TMQZ2 303A UTUNPLGAL013 X201...

Страница 71: ...or CE1AMASDL101 ELECTROLYTIC CAP 100 F 10V M CE1AMASTL101 CONNECTORS CN551 CONNECTOR BASE 5P TV 50P 05 V3 or J3TVC05TG002 CONNECTOR BASE 5P RTB 1 5 5P or J3RTC05JG001 CONNECTOR 5P PB FREE 200322305W8...

Страница 72: ...07 TRANSISTOR 2SC2120 Y TE2 F T or QQSY2SC2120F Ref No Description Part No TRANSISTOR 2SC2120 O TE2 F T or QQS02SC2120F TRANSISTOR KTC3203 Y AT P NQSYKTC3203P Q608 TRANSISTOR 2SC2785 F or QQSF02SC2785...

Страница 73: ...01 FUSE HOLDER MSF 015 or XH01Z00LY001 FUSE HOLDER FH V 03078 XH01Z00DK001 FH602 FUSE HOLDER MSF 015 or XH01Z00LY001 FUSE HOLDER FH V 03078 XH01Z00DK001 PB1 POWER PCB HOLDER T6400RA 0EM000696A Ref No...

Страница 74: ...124 R516 CARBON RES 1 4W J 15 RCX4JATZ0150 R517 CARBON RES 1 4W J 560 RCX4JATZ0561 R518 CARBON RES 1 4W J 120k RCX4JATZ0124 R519 CARBON RES 1 4W J 15 RCX4JATZ0150 R520 CARBON RES 1 4W J 560 RCX4JATZ05...

Страница 75: ...T6609BK T6609BK 2005 06 24...

Отзывы: