EWM-BUS-DD/10  

80946/118 ETM 

 

Duplomatic MS

 ▪  EWM-BUS-DD/10  Start-up Manual – 80946/118 ETM --- Oct 2018

 | 

Characteristics 

This card is a Profibus/CANbus coupler for systems up to 24 axes.  

It allows the data exchange between a CAN network and PROFIBUS PLC, through a built

-in 

interface inside one housing.  

The EWM-BUS-DD, combined with cards for axes control like EWM-SS-DAD (catalogue 89460), 
allows to design synchronization systems with CAN communication on the axes network side, and 
with PROFIBUS communication on PLC side.  

7-segment display makes diagnosis and commissioning easier. 

Configure the CAN communication by DIL-switches. For PROFIBUS setting, load the .GSD file 
(www.duplomatic.com, inside download section.)  

 

Power supply 

VDC  24  

Current consumption 

mA 

< 120 (a 24 V)

 

Connections 

 

PROFIBUS: D-sub  9-pin CAN: 4-pin COMBICON plug 

Insulation voltage 

 

≥ 500 V

 

Baud rates 

 

9,6 Kbaud to 12000 Kbaud, automatic recognition 

CAN baud rates 

 

125 Kbaud, 250 Kbaud, 500 Kbaud, 1 Mbaud 

DP function 

 

imaging of the CAN Data as I/O data of the PROFIBUS complete 
diagnosis and configuration via DP master 

Profibus interface 

 

according to DIN 19245 part 1-3 

Housing material 

 

Plastic 

Dimensions 

mm  120 x 99(h) x 25(w)   

Connectors 

 

2x4 poles screw terminals - PE direct via DIN rail  

Operating 
temperature range 

°C 

0 / +55 

Protection degree 

 

IP 20 housing 

 

 

 

Содержание EWM-BUS-DD series 10

Страница 1: ...80946 118 ETM EWM BUS DD 10 CAN Coupler Start up manual Duplomatic MS S p A...

Страница 2: ...M 2 Duplomatic MS S p A All rights reserved TABLE OF CONTENTS GENERAL INFO 3 Contacts 3 Safety instructions 4 Characteristics 5 INSTALLATION 6 Settings 6 GSD configuration file 7 Display 7 PROFIBUS so...

Страница 3: ...tion about EWM BUS DD 10 can be found in Technical catalogue 89460 ED edition 118 Configuration file GSD Profibus EWM BUS DD EWM SS DAD available at www duplomatic com For installation start up commis...

Страница 4: ...nected and put into operation by trained specialist staff The instruction manual must be read with care The installation instructions and the commissioning instructions must be followed Guarantee and...

Страница 5: ...commissioning easier Configure the CAN communication by DIL switches For PROFIBUS setting load the GSD file www duplomatic com inside download section Power supply VDC 24 Current consumption mA 120 a...

Страница 6: ...provided with an active bus termination at the beginning and at the end The termination is already integrated in all common Profibus plugs and can be activated by a DIL switch Settings The module sup...

Страница 7: ...guration The tables below show the meaning of DIL Switches GSD configuration file The GSD file is available for download at www duplomatic com site in the download section Display The EWM BUS DD has a...

Страница 8: ...ed PROFIBUS socket Use a shielded typical PROFIBUS connector 9 pin with internal terminal resistors to be set properly The pre set address of the module can be changed only by Profibus DEFAULT is 3 De...

Отзывы: