CURVE ADJUSTMENT
Command
Parameters
Unit
User Level/Group
Default
ADJ_MIN
ADJ_MAX
ADJ_TRIGGER
0-50
ADJ_MIN
–
120
0-20
%
USR / M1
0
100
1.5
ADJ_MIN_A
ADJ_MAX_A
ADJ_TRIGGER
ADJ_MIN_B
ADJ_MAX_B
0-50
ADJ_MIN_A
–
120
0-20
0-50
ADJ_MIN_B
–
120
%
USR / M2
0
100
1.5
0
100
ADJ1_MIN
ADJ1_MAX
ADJ1_TRIGGER
ADJ2_MIN
ADJ2_MAX
ADJ2_TRIGGER
0-50
ADJ1_MIN
–
120
0-20
0-50
ADJ2_MIN
–
120
0-20
%
USR / M3
0
100
1.5
0
100
1.5
With these commands, the
output signal is adjusted to the valve characteristics
.
The unit is percentage of nominal current (defined by CURRENT parameter).
The output signal (the maximum valve current) will be defined
with the ‘MAX’ value
. The
overlap (dead band of the valve) will be compensated w
ith the ‘MIN’ value
. Via the TRIGGER
the activation point of the MIN function is set and so a non-sensitive range around the zero-
point can be specified.