Dungs HPSV 10020/604 Скачать руководство пользователя страница 8

8 … 8

MC • Karl Dungs

, Inc.

 • HP

SV 10020/604 • Edition 2017.05 • P/N 264712

Replacement Coil

Valve Type

Voltage

Order No.

HPSV 10020/604 (Coil)

24 VDC

270888

Accessories & Replacement

Karl Dungs GmbH & Co. KG

P.O. Box 12 29

D-73602 Schorndorf, Germany

Phone  +49 (0)7181-804-0

Fax  +49 (0)7181-804-166

e-mail [email protected]

Internet http://www.dungs.com

Karl Dungs, Inc.

3890 Pheasant Ridge Drive NE

Suite 150

Blaine, MN 55449, U.S.A.

Phone 763 582-1700

Fax  763 582-1799

e-mail [email protected]

Internet http://www.dungs.com/usa/

We reserve the right to make modifications in the course of technical development.

Содержание HPSV 10020/604

Страница 1: ...find the instruction also at www dungs com If these instructions are not heeded the result may be personal injury or damage to property Any adjustment and application specific adjustment values must b...

Страница 2: ...wer than 15 F and its relative humidity is less than 60 Materials in contact with Gas Housing Anodized Aluminium and Steel free of non ferrous metals Sealingsonvalveseats NBR based rubber F Electrical...

Страница 3: ...nsert studs tighten in a crisscross pattern to ensure uni form tightness 5 Do not overtighten studs Follow the maximum torque values listed 6 After installation is complete perform a leak test see Val...

Страница 4: ...2 A and rated for at least 75 C 167 F Radiant heat must be considered as a heat source that could result in an ambient temperature higher than the rating of this valve Provide propor shielding to pro...

Страница 5: ...7 05 P N 264712 Dimensions b c g e d a f Upstream 1 4 NPT Tap Downstream 1 4 NPT Tap Type Order No Dimensions inch Dimensions mm Weight lbs kg a b c d e f g HPSV 10020 604 270890 2 95 75 8 82 224 6 30...

Страница 6: ...flexible hose of some convenient length provides for a more accurate leakage measurement However a 45 cut at the end of the 1 4 flexible hose will suffice but it will not likely be as accurate as the...

Страница 7: ...d For ex ample when using propane divide the volume CFH of propane required for the application by the calculated value f f 0 66 for propane Use this cor rected flow rate and the flow curve on the nex...

Страница 8: ...P O Box 12 29 D 73602 Schorndorf Germany Phone 49 0 7181 804 0 Fax 49 0 7181 804 166 e mail info dungs com Internet http www dungs com Karl Dungs Inc 3890 Pheasant Ridge Drive NE Suite 150 Blaine MN 5...