Dungs EMP-5 Скачать руководство пользователя страница 1

1 … 9

MC • Karl Dungs

, Inc.

 • EMP-5 • Edition 2017.05 • P/N 261483

EMP-5 

Current or Voltage Input 

Drive Modulating Actuator

Installation Instruction

Table of Contents

USA

CDN

Table of Contents   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . Page 1

Approvals  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . Page 1

Attention  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . Page 1

Specification   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . Page 2

Operation Description   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . Page 3

Installation   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . Page 3

Replacing EMP-3 or EMP-4 with EMP-5  .  .  .  .  .  . Page 3

Standard Wiring of EMP-5   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . Page 4

Adjustment  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . Page 5

Adjustment  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . Page 6

Potentiometer Adjustment and Jumpers .  .  .  .  . Page 6

Testing .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . Page 7

Technical Tips and Data  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . Page 7

Troubelshooting   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . Page 7

Dimensions   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . Page 8

Approvals

1, 2, 3  . . . 

= Action

= Instruction

Explanation of symbols

Attention

Please read the instruction be-

fore installing or operating . Keep 

the instruction in a safe place . You 

find the instruction also at www.

dungs .com If these instructions 

are not heeded, the result may 

be personal injury or damage to 

property .

Any adjustment and application-

specific adjustment values must 

be made in accordance with 

the equipment manufacturers 

instructions .

Safety

first

O.K.

Accessories & Replacement   .  .  .  .  .  .  .  .  .  .  .  .  .  .  . Page 9

The installation and maintenance 

of this product must be done 

under the supervision of an ex-

perienced and trained specialist . 

Never perform work if gas pres-

sure or power is applied, or in 

the presence of an open flame.

On completion of installation on 

the EMP, perform a function test .

This product is intended to be 

used in combination with a con-

trol valve to modulate the flow of 

gas or air .

IFGC

CSA

UL

ANSI

NFPA

UL Listed: UL 873 and CSA C22 .2 No . 24-93

Содержание EMP-5

Страница 1: ...n be foreinstallingoroperating Keep theinstructioninasafeplace You find the instruction also at www dungs com If these instructions are not heeded the result may be personal injury or damage to proper...

Страница 2: ...ning 34 8 A locked rotor Grounded Input Grounding either or both input wires will not cause Fuse There is no internal fuse The EMP is impedence protected Model No Order No Travel Description Timing se...

Страница 3: ...e them off and safely stow away Replacing EMP 3 or EMP 4 with EMP 5 When replacing an EMP 3 or EMP 4 with an EMP 5 and if the high fire override is not used then follow the wiring schematic EMP 4 to E...

Страница 4: ...oltage to terminals input leads or to X 2 3 4 7 or 8 will permanently damage the motor Field Wiring Terminal Block Internal Wiring Low Voltage Leads for Driving Actuator 4 20 mAdc Controller Input Sli...

Страница 5: ...wise end of actuator rotation Each click of the cam represents about 3 change in operating point NOTE After turning the disc remove back plate and reposition the wiper it will need to be repositioned...

Страница 6: ...e mA input equals the desired finish point maximum position This is typically 20 mA 3 With the desired current input for maximum position typi cally 20mA the actuator will drive towards 90 degrees Onc...

Страница 7: ...ading windings The voltage on the shading windings is about 30 VAC and the voltage on the main windings is 120 VAC Tech Tip 2 Maximum voltage to terminals 7 and 8 is 24 VAC During operation the voltag...

Страница 8: ...7 05 P N 261483 Mounting holes 3 17 64 6 7 mm Dia 3 1 4 83 mm 4 3 4 121 mm 4 102 mm Shaft Dia 1 2 13 mm 2 1 4 57 mm 1 5 8 41 mm 2 1 4 57 mm 4 102 mm 2 51 mm 1 8 3 mm 7 1 4 184 mm 2 3 4 70 mm 2 1 4 57...

Страница 9: ...267191 AE 504 Paralleling Relay for driving up to 3 actuators with one input signal 269237 AM 132 5 16 hole ball joint linkage swivel connector for non parallel linking 269232 AM 122 5 16 hole straigh...