background image

 
 

 

Dulas VC225ILR User Manual 

 

Page 9 of 15 

 
 

 

6. 

  End of Life & Product Recycling 

 

PACKAGING 

 

The packaging is made from recyclable / reusable materials and should be brought to an official 

recycling centre. The materials used are: 

  Heat treated (HT) timber, certified by UK Forestry Commission (ISPM No. 15 Mark) 

  Corrugated cardboard / Cardboard 

  Polyethylene plastic 

  Moulded polystyrene parts 

  Steel reinforcing straps 

 

WARNING 

 

Keep packaging away from children - danger of suffocation from plastic! 

 

WORN OUT REFRIGERATOR 

 

The  refrigerator  still  contains  valuable  materials  and  is  not  to  be  disposed  of  in  the  normal 

household waste.  

  Ensure  that  the  cooling  circuit  of  the  worn  out  device  is  not  damaged  when  being 

transported. 

  Information on the coolant used is on the type plate on the back of the refrigerator. 

  The walls of the refrigerator contain an organic phase change material that can be harmful 

and must be disposed of safely. Please contact Dulas for advice. 

  Worn out devices must be professionally disposed of in accordance with local regulations 

and legislation. 

 

Potentially hazardous components / materials are

  Refrigerant gas (R600a) 

  Phase change material (PCM) - paraffins, normal C5-20 

  Electrolytic capacitor 

  Electronic components      

–  Refrigerator controller 

Compressor controller 

Refrigerator compartment temperature display 

 

Disposal of Phase Change Material (PCM) 

The PCM used in the Dulas refrigerator has a very long life and does not degrade through use. At 

the  end  of  the  refrigerators  useful  life  the  PCM  should  be  either  recycled  or  disposed  of  in 

accordance  with  applicable  regional,  national  and  local  laws  and  regulations.  Contact  your  local 

waste  disposal  authority  for  advice.  The  product  can  be  incinerated  in  accordance  with  local 

regulations.  In  the  EU  it  has  a  Waste  Disposal  Code  (EWC): 

13  08  99  oil  waste  not  otherwise 

specified.

 

 

Содержание VC225ILR

Страница 1: ...DULAS VC225ILR Mains Powered Vaccine Refrigerator User Manual Ref MU VC225ILR ENG F ...

Страница 2: ...STRUCTIONS 4 3 YOUR DULAS MAINS POWERED REFRIGERATOR 6 4 REFRIGERATOR COMPONENTS 7 5 MATERIAL SAFETY INFORMATION 8 6 END OF LIFE PRODUCT RECYCLING 9 7 REFRIGERATOR INSTALLATION 11 8 REFRIGERATOR LOADING 12 9 STATUS LIGHT 13 10 USER TRAINING 14 11 MAINTENANCE TASKS 15 12 VC225ILR SYSTEM LAYOUT 15 ...

Страница 3: ... QUANTITY REFRIGERATOR VC225ILR Refrigerator Cabinet 1 Refrigerator Baskets 6 Refrigerator Key 2 Other Power Supply PS ILR 001 1 Screws 5x40mm for wall mount 5 Wall plugs Brown for wall mount 5 Screws 10 Wall plugs Red 10 Cable ties 10 Cable tie bases 10 MC connection tool 1 ...

Страница 4: ... must be supervised not to play with the appliance This refrigerator is for professional use only It is not designed for household use Refrigerator and power system are heavy please observe good manual handling procedures when moving the refrigerator and solar power system Only use suitable transport equipment Live electrical components The refrigerator operates from low voltage DC There are high ...

Страница 5: ...refrigerant Due to this fact the following information is particularly important Warning Do not damage the refrigeration circuit Ensure that sharp or pointed objects do not come into contact with the refrigeration circuit Warning Do not use mechanical devices or other means to accelerate the defrosting process other than those recommended by the manufacturer Warning Keep ventilation openings in th...

Страница 6: ...erature when the power is off the Dulas ILR has a phase change lining This lining acts as a cold store and stores energy that keeps the temperature inside the refrigerator stable when electricity is not available The temperature of the cold store in the Dulas ILR is naturally between 4 to 5 C which is the perfect temperature required for safe vaccine storage and means that the product is 100 Freez...

Страница 7: ...Dulas VC225ILR User Manual Page 7 of 15 4 Refrigerator Components ...

Страница 8: ...red inside the walls of the refrigerator In normal use the user will never be aware of its presence This PCM is classified under regulation EC No 1272 2008 as a category 1 aspiration hazard and is classified under regulation 67 548 EWG 1999 45 EG as having the potential to cause physical harm R65 R66 At normal ambient temperatures this product will be unlikely to present an inhalation hazard becau...

Страница 9: ...igerator contain an organic phase change material that can be harmful and must be disposed of safely Please contact Dulas for advice Worn out devices must be professionally disposed of in accordance with local regulations and legislation Potentially hazardous components materials are Refrigerant gas R600a Phase change material PCM paraffins normal C5 20 Electrolytic capacitor Electronic components...

Страница 10: ...nd its implementation as national law electrical equipment that has reached the end of its life must be collected separately and returned to an approved recycling facility Any device that you no longer require must be returned to our agent or find out about the approved collection and recycling facilities in your area Ignoring this European Directive may have potentially adverse effects on the env...

Страница 11: ...fficient slack in the cable to allow access to the back of the refrigerator 4 Plug the Dulas PS ILR 001 into a suitable AC outlet and turn it on Then switch the DC isolator to the 1 position Within 1 minute the compressor will start if there is AC power You will be able to hear the compressor operating and feel the condensers getting warm 5 Check that the refrigerator compartment temperature displ...

Страница 12: ...e vaccine compartment that drop below freezing and thus no danger of freezing vaccines Optional stacking baskets are available These are designed to make stock management easier and encourage air circulation within the compartment Try to keep the lid open for as short a time as possible Stock management Allocate a certain space for each different type of vaccine so that they may be located rapidly...

Страница 13: ...wer Normal operation The refrigerator warms up slightly overnight It is usual for the compressor to start running shortly after sunrise It will run continuously for a few hours to cool the refrigerator After this time the compressor will begin cycling on and off to maintain the correct internal temperature This will continue until the sun sets at the end of the day At night there is no power to th...

Страница 14: ... in accordance with the table below Total No of hours the power is off each day Running time required before full holdover is achieved at 43 C ambient Continuous operation possible once cool down has been achieved 0 2 days Y 12 4 5 days Y 16 7 days Y 20 14 days Y Before loading with vaccines ensure that the temperature display on the front of the refrigerator reads 4 5 C Daily Routine Keep the lid...

Страница 15: ...s Every morning and afternoon Check the temperature Fill in the daily record sheet On the first day of every month Clean the refrigerator condensers and compressors Every 6 months Check all mechanical fixings and electrical connections 12 VC225ILR System Layout ...

Отзывы: