background image

VC200SDD Refrigerator User

’s Manual 

 

Page 6 of 17 

 
 

 

3. 

 

Your Dulas Solar Direct Drive Refrigerator. 

 

Congratulations  on  choosing  the  Dulas  VC200SDD  vaccine  refrigerator.    With  over  30  years  of 

engineering  experience  in  the  production  of  solar  powered  vaccine  refrigerators,  Dulas  is 

considered one of the market leaders in this field. 

 

The VC200SDD is 

Dulas’ latest innovation in solar refrigeration.  Using our new solar direct drive 

technology  we  have  replaced  the  traditional  battery  energy  store  with  a  ground  breaking  phase 

change  solution.  With  this  new  technology  we  can  offer  the  same  renown  Dulas  quality  and 

reliability that have always kept your vaccines safe, but in a simpler and more efficient package.  

 

 

How does solar direct drive work?  

 

When  the  sun  shines  the  solar  panels  generate  electricity  which  directly  drives  the  refrigerators 

compressor,  cooling  down  the  refrigerator  and  its  contents.    As  a  result  the  compressor  only 

operates during the day. To maintain the temperature at night or when the sun is not shinning the 

refrigerator  has  a  phase  change  lining. This  interior  lining  holds  the  exact  temperatures required 

for  safe  vaccine  storage  and  acts  as  a 

“cold  store”,  storing  energy  that  keeps  the  temperatures 

stable all day and night. 

 

In order to store sufficient energy to keep vaccines safe for prolonged periods without any 

sunshine,  the  refrigerator  must  be  allowed  time  to  charge 

it’s  cold  store.    Under  normal 

sunlight  conditions  (8  hours/day  of  solar  irradiance  >200W/m²)  the  refrigerator  will  take 

approximately 7 days to fully charge the cold store and be ready for vaccine storage.  

 

Recommended solar array 

 

The VC200SDD has been designed to meet the World Health Organi

sation’s Performance, Quality 

&  Safety  (PQS)  standards.  The  refrigerator  has  been  independently  tested  to  the  PQS  standard 

WHO/PQS/E03/RF05  and  is  a  Hot  zone  rated  appliance  with  an  ambient  operating  temperature 

range of b5C and +43C. For use in such Hot Zone environments it should be powered by 

a  minimum  400  peak  Watt  (Wp)  solar  array  with  an  open  circuit  voltage  (VOC)  not  exceeding 

45Vdc. 

 

Содержание VC200SDD

Страница 1: ...DULAS Solar Direct Drive VC200SDD Refrigerator User s Manual Ref MU VC200SDD ENG E ...

Страница 2: ...S 4 3 YOUR DULAS SOLAR DIRECT DRIVE REFRIGERATOR 6 4 REFRIGERATOR COMPONENTS 7 5 MATERIAL SAFETY INFORMATION 8 6 END OF LIFE PRODUCT RECYCLING 9 7 REFRIGERATOR INSTALLATION 12 8 REFRIGERATOR LOADING 13 9 GREEN COMPRESSOR STATUS LED LIGHT 14 10 USER TRAINING 15 11 MAINTENANCE TASKS 15 12 VC200SDD SYSTEM LAYOUT 16 ...

Страница 3: ...olar Connector Branch Plug 1 Solar Connector Branch Socket 1 Earthing Kit incl Earth Rod 25m Earth Cable Earth Clamp 1 MOUNTING SYSTEM see page 14 for references A to G A End Clamp 34 42mm Set 4 B Mid Clamp 28 42mm Set 2 C Front fixed leg 2 D C Rail 47 3 1530mm 2 E C Rail 47 3 750mm 2 F Rear adjustable leg 2 G Rail connector set 47 2 Coachscrews Rawbolts Washers 2 packs Screws 1 pack Wall Plugs 1 ...

Страница 4: ...een given supervision or instruction Children must be supervised not to play with the appliance This refrigerator is for professional use only It is not designed for household use Refrigerator and power system are heavy please observe good manual handling procedures when moving the refrigerator and solar power system Only use suitable transport equipment Safe working Please observe safe working at...

Страница 5: ... Do not expose it to rain WARNING This unit s cooling system contains flammable refrigerant Due to this fact the following information is particularly important Warning Do not damage the refrigeration circuit Ensure that sharp or pointed objects do not come into contact with the refrigeration circuit Warning Do not use mechanical devices or other means to accelerate the defrosting process other th...

Страница 6: ...s during the day To maintain the temperature at night or when the sun is not shinning the refrigerator has a phase change lining This interior lining holds the exact temperatures required for safe vaccine storage and acts as a cold store storing energy that keeps the temperatures stable all day and night In order to store sufficient energy to keep vaccines safe for prolonged periods without any su...

Страница 7: ...VC200SDD Refrigerator User s Manual Page 7 of 17 4 Refrigerator Components ...

Страница 8: ...lammable when mixed with air Do not inhale ingest and avoid contact to skin Ensure that any work carried out on the refrigeration circuit is done by a competent refrigeration engineer THE PHASE CHANGE MATERIAL PCM The refrigerator contains an organic phase change material PCM that provides the energy store for the refrigerator This PCM material is a paraffin wax that is liquid at room temperature ...

Страница 9: ...y escaping material If the PCM contaminates rivers and lakes or sewers inform respective authorities Avoid water ingress underground Do not flush into surface water or sanitary sewer system 6 End of Life Product Recycling PACKAGING The packaging is made from recyclable reusable materials and should be brought to an official recycling centre The materials used are Heat treated HT timber certified b...

Страница 10: ...rolytic capacitor Electronic components SDD controller Compressor controller Refrigerator compartment temperature display Disposal of Phase Change Material PCM The PCM used in the Dulas refrigerator has a very long life and does not degrade through use At the end of the refrigerators useful life the PCM should be either recycled or disposed of in accordance with applicable regional national and lo...

Страница 11: ...oved recycling facility Any device that you no longer require must be returned to our agent or find out about the approved collection and recycling facilities in your area Ignoring this European Directive may have potentially adverse effects on the environment and your health Solar modules contain materials that can be recovered and reused in either new PV modules or other new products Industrial ...

Страница 12: ...lack in the cable to allow access to the back of the refrigerator 4 Turn the PV isolator on by switching it to 1 Within 1 minute the compressor will start if there is sufficient sunlight solar irradiance of 125W m You will be able to hear the compressor operating and feel the condensers getting warm 5 Check that the refrigerator compartment temperature display on the front of the cabinet is operat...

Страница 13: ...ke stock management easier and encourage air circulation within the compartment Do not remove these baskets and do not store vaccines outside of these baskets The wire baskets encourage the circulation of air by maintaining a small gap between the basket and the cabinet wall Good air circulation will help the refrigerator to maintain an even temperature throughout the compartment In order to save ...

Страница 14: ...icient solar power Normal operation The refrigerator warms up slightly overnight It is usual for the compressor to start running shortly after sunrise It will run continuously for a few hours to cool the refrigerator After this time the compressor will begin cycling on and off to maintain the correct internal temperature This will continue until the sun sets at the end of the day At night there is...

Страница 15: ... open only when required and lock after use Store the most frequently used vaccines in the top baskets for easy access Do not keep food or drink in the refrigerator Vaccine Storage Only store vaccines in the refrigerator Use the baskets provided Do not store vaccines outside the baskets Always store vaccine in its original packaging Always keep the same type of vaccine together and store your vacc...

Страница 16: ...VC200SDD Refrigerator User s Manual Page 16 of 17 12 VC200SDD System Layout ...

Страница 17: ...rigerator User s Manual Page 17 of 17 For more information contact DULAS Ltd Dyfi Eco Park Machynlleth Powys SY20 8AX UK tel 44 0 1654 705055 fax 44 0 1654 703000 email solar dulas org uk website www dulassolar org ...