Installation and Operation of: Refrigerated Back Counter

INTRODUCTION

SPECIFICATION

This publication contains information regarding the installation and operation of Duke Refrigerated Back Counter 
units. The information contained within applies to the models RBC 48 and RBC 60. Please read this manual completely 
before attempting to install and/or operate this equipment. 

Model number RBC 48 describes the 48” wide version of the Refrigerated Back Counter. (Fig. 1)
Model number RBC 60 describes the 60” wide version of the Refrigerated Back Counter. (Fig. 2)

Figure. 1 

RBC 48

Figure. 2 

RBC 60

Model

Volts

Frequency 

(Hz)

Amps

Watts 

(Label)

HEIGHT

in,  (cm)

WIDTH

in,  (cm)

LENGTH

in,  (cm)

RBC-48

120

60

3.9

N/A

40.0 (101.6)

29.50 (74.9)

48.0 (121.9)

RBC-48

220

60

2.8

616

40.0 (101.6)

29.50 (74.9)

48.0 (121.9)

RBC-48

230

50

2.7

621

40.0 (101.6)

29.50 (74.9)

48.0 (121.9)

RBC-60

120

60

3.9

N/A

40.0 (101.6)

29.50 (74.9)

60.0 (152.4)

RBC-60

220

60

2.8

616

40.0 (101.6)

29.50 (74.9)

60.0 (152.4)

RBC-60

230

50

2.5

575

40.0 (101.6)

29.50 (74.9)

60.0 (152.4)

SERIAL NUMBER

Always have the serial number of your unit available when calling for parts or service. 

(74.9cm)

(101.6cm)

(121.9cm)

(74.9cm)

(152.4cm)

(101.6cm)

Содержание RBC 48

Страница 1: ...229917 REV B 1 8 2019 This manual is Copyright 2018 Duke Manufacturing Co All rights reserved Reproduction without written permission is prohibited Duke is a registered trademark of the Duke Manufacturing Co CAUTION Please read this manual completely before attempting to install operate or service this equipment RBC 48 RBC 60 ...

Страница 2: ...UTION Indicates Important Information Indicates electrical shock hazard which if not avoided could result in death or serious injury and or equipment damage Indicates hot surface which if not avoided could result in minor or moderate injury TABLE OF CONTENTS Important Safety Instructions 2 Introduction 4 Specifications 4 Serial Number 4 Receiving Inspecting the Equipment 5 Installation 5 Location ...

Страница 3: ...ice or maintenance on the unit The procedures in this manual may include the use of chemical products You must read the Material Safety Data Sheets before using any of these products The unit should be grounded according to local electrical codes to prevent the possibility of electrical shock It requires a grounded receptacle with dedicated electrical lines protected by fuses or circuit breaker of...

Страница 4: ...mber RBC 60 describes the 60 wide version of the Refrigerated Back Counter Fig 2 Figure 1 RBC 48 Figure 2 RBC 60 Model Volts Frequency Hz Amps Watts Label HEIGHT in cm WIDTH in cm LENGTH in cm RBC 48 120 60 3 9 N A 40 0 101 6 29 50 74 9 48 0 121 9 RBC 48 220 60 2 8 616 40 0 101 6 29 50 74 9 48 0 121 9 RBC 48 230 50 2 7 621 40 0 101 6 29 50 74 9 48 0 121 9 RBC 60 120 60 3 9 N A 40 0 101 6 29 50 74 ...

Страница 5: ... service to the refrigeration system is done from the end of the cabinet The outline dimensional drawings for the units are shown in Figures 1 and 2 INSTALLATION Inside Unit Take care not to block air flow to the fans and allow space along the front back and sides INSTALLATION Outside Unit Be sure that the unit has access to ample air avoid hot corners and locations near stoves and ovens CAUTION Th...

Страница 6: ...ature Allow time for temperature changes before making a final temperature check MAINTENANCE Stainless Steel Care Cleaning To prevent discoloration or rust on stainless steel several important steps need to be taken Stainless steel contains 70 80 iron which will rust It also contains 12 30 chromium which forms an invisible passive film over the steels surface which acts as a shield against corrosion...

Страница 7: ...y rinsing with water Allow to dry completely before reinstalling The condenser coil requires regular cleaning and is recommended every 60 days However in some instances you may find that there is a large amount of debris dust or grease that has accumulated prior to the 60 day time frame In these cases the condenser coil should be cleaned every 30 days If the build up on the coil consists of only li...

Страница 8: ... has a copper drain tube located inside the unit which removes condensation from the evaporator coil and deposits it onto a drain pan where it can evaporate See Fig 6 If you notice excessive water accumulation on the inside of the unit be sure that the drain tube is connected from the evaporator housing to the condensate evaporator drain pan If water is collecting underneath the unit you may want ...

Отзывы: