background image

 

  

NEC Display Solutions of America, Inc.

                    

M283X/M323X/M363X/M403X Installation Guide 

Ceiling Mounted and Desktop 

 

                       

Rev 1.0 

www.necdisplay.com

                                                                              

M283X, M323X, M362X, M403X                         

Page 6 of 6 

 

Input 

Output 

Panel                              

 

 

 

 

 

 

 

 

  

 

 

 

             

PC 

Control 

Codes 

                              

                               
Function 

 

           Code 

Data 

              

POWER 

ON 

 

          02H  00H  00H   00H   00H   02H      

POWER 

OFF 

 

          02H 

 01H 

 00H 

 00H 

 00H 

 03H      

INPUT 

SELECT 

COMPUTER1      02H 

 03H 

 00H 

 00H 

 02H   01H   01H   09H  

INPUT 

SELECT 

HDMI 

1        02H  03H  00H  00H  02H  01H 1AH 22H  

INPUT 

SELECT 

HDMI 

2        02H  03H  00H  00H  02H  01H 12H AAH  

INPUT SELECT VIDEO    

 

 

 

 

 

 

02H   03H   00H   00H   02H   01H   06H   0EH   

INPUT 

SELECT 

VIEWER 

 

       02H 

 03H 

 00H 

 00H 

 02H   01H   1FH   27H  

INPUT SELECT NETWORK   

 

 

 

 

 

02H   03H   00H   00H   02H   01H   20H   28H  

INPUT SELECT USB DISPLAY   

 

 

 

 

02H   03H   00H   00H   02H   01H   22H   2AH  

PICTURE 

MUTE 

ON 

 

        02H 

 10H 

 00H 

 00H 

 00H 

 12H      

PICTURE 

MUTE 

OFF 

 

        02H 

 11H 

 00H 

 00H   00H   13H      

SOUND 

MUTE 

ON 

         02H 

 12H 

 00H 

 00H 

 00H 

 14H      

SOUND 

MUTE 

OFF 

 

        02H 

 13H 

 00H 

 00H  00H   15H      

PROJECTOR 

INFORMATION 

REQUEST 

   00H 

 BFH 

 00H 

 00H  01H   02H C2H    

ERROR 

STATUS 

REQUEST 

      00H 

 88H 

 00H 

 00H  00H   88H      

INFORMATION 

REQUEST       03H 

 8AH 

 00H 

 00H 00H 

 8DH      

Note:

 

Contact your              rep for codes not listed.

 

 

Cable 

Connection                               

Communication Protocol: 

Baud 

Rate: 

  38400 

bps 

             

Data Length:    8 bits 
Parity: 

   No Parity 

Stop Bit:      One Bit 

on/off:   None 

Communications: Full duplex 

                                                                                                                   

 

PC Control Connector (D-Sub 9P)

   

 

 

NOTE 1 : 

Pins 1, 4, 6, and 9 are used inside the projector. 

NOTE 2:  

For long cable runs it is recommended to set communication speed within the projector to 9600 bps.

   

NOTE 3:   

Jumper “Request to Send” and “Clear to Send” together on both ends of the cable to simplify cable connection. 

1 2 3 4 5

6 7 8 9

To GND of PC

To RxD of PC

To TxD of PC

To CTS of PC

To RTS of PC

www.dukaneav.com   

6528A-6532A-6536A-6540A_Installation Guide rev 00  

              Page 6 of 6

6528A/6532A/6536A/6540A Installation Guide

Ceiling 

Mounted 

and 

Desktop 

        

Rev 1.0

Dukane AV Division

Dukane

Содержание 6528A

Страница 1: ... 2 for 100 diagonal F 2 4 3 1 Screen Sizes 30 300 diagonal 4 3 Manual Focus Manual Zoom Notes For screen sizes not indicated on the projection tables use the formulas below If the figures on the tables do not match the results of formulas use the figures in the table All calculations are based on a 4 3 aspect ratio Distances are in inches for millimeters multiply by 25 4 Distances may vary 5 Formu...

Страница 2: ...iagonal Width W Height H inches inches inches inches 30 24 18 12 35 60 18 2 10 9 60 48 36 23 72 123 17 8 10 7 67 54 40 2 26 81 138 17 8 10 7 72 58 43 2 28 87 148 17 8 10 7 84 67 50 4 33 102 173 17 8 10 6 90 72 54 35 109 186 17 7 10 6 100 80 60 39 122 207 17 7 10 6 120 96 72 47 146 249 17 7 10 6 150 120 90 58 183 312 17 6 10 6 180 144 108 70 221 375 17 6 10 6 210 168 126 82 258 438 17 6 10 6 240 19...

Страница 3: ... drawings show the cabinet dimensions Dimensions are in inches For millimeters multiply by 25 4 2 378 4 232 2 299 3 839 14 5 1 1 5 1 1 3 AC INLET ZOOM LEVER FOCUS LEVER LENS CENTER LENS COVER LAMP AIR INTAKE IR RECEIVER EXHAUST www dukaneav com 6528A 6532A 6536A 6540A_Installation Guide rev 00 Page 3 of 6 6528A 6532A 6536A 6540A Installation Guide Ceiling Mounted and Desktop Rev 1 0 Dukane AV Divi...

Страница 4: ...s continued The following drawings show the cabinet dimensions Dimensions are in inches For millimeters multiply by 25 4 5 232 7 417 6 571 5 87 9 484 0 197 7 677 6 89 5 118 5 906 M4 x 8 Depth FOR CEILING MOUNT KIT www dukaneav com 6528A 6532A 6536A 6540A_Installation Guide rev 00 Page 4 of 6 6528A 6532A 6536A 6540A Installation Guide Ceiling Mounted and Desktop Rev 1 0 Dukane AV Division ...

Страница 5: ... Optional Ceiling Mount Dimensions Model MP300CM The following drawings show the ceiling mount dimensions Dimensions are in inches For millimeters multiply by 25 4 or use universal mount PRG UNV www dukaneav com 6528A 6532A 6536A 6540A_Installation Guide rev 00 Page 5 of 6 6528A 6532A 6536A 6540A Installation Guide Ceiling Mounted and Desktop Rev 1 0 Dukane AV Division ...

Страница 6: ...H 00H 00H 00H 14H SOUND MUTE OFF 02H 13H 00H 00H 00H 15H PROJECTOR INFORMATION REQUEST 00H BFH 00H 00H 01H 02H C2H ERROR STATUS REQUEST 00H 88H 00H 00H 00H 88H INFORMATION REQUEST 03H 8AH 00H 00H 00H 8DH Note Contact your rep for codes not listed Cable Connection Communication Protocol Baud Rate 38400 bps Data Length 8 bits Parity No Parity Stop Bit One Bit X on off None Communications Full duplex...

Отзывы: