![Duerkopp Adler DACeco M-TYPE Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/duerkopp-adler/daceco-m-type/daceco-m-type_operating-manua_2538385017.webp)
Setting the basic functions
17
© 2013 Dürkopp Adler AG
0791 100632 EN
7
Setting the basic functions
With S1 and S2, the DAC
eco M-TY PE
can be programmed to a lesser degree.
There are six parameters listed in the table that can be changed.
Parameter
Min
Max
Unit
1
Soft start stitches
1
20
Stitches
2
Soft start speed
100
1000
rpm
3
Maximum speed
100
3400*
rpm
4
Holding force
0
6
A
5
Needle positions and reference position
-
-
-
6
Machine selection
1
7
-
*Depence of the selected machine class.
To access the programming mode, keep S1 pressed when turning on the control unit.
Once the programming mode is active and the corresponding parameter can be selected, LED2 flashes.
Buttons S1 and S2 have the following functions in programming mode:
Confirmation - Keep S1 (OK) pressed (> one second)
Cancellation - Keep S2 ( ESC) pressed (> one second)
Plus - Briefly press S1 (+) (< one second)
Minus - Briefly press S2 (-) (< one second)
Select the corresponding parameter by briefly pressing S1.
The LED allocated to S1 indicates the currently selected parameter.
Confirm by keeping S1 pressed > one second.
Example: Briefly press S1 twice = programming the soft start speed. The corresponding LED repeatedly briefly
flashes twice.
Содержание DACeco M-TYPE
Страница 15: ...Assembly instructions 15 2013 Dürkopp Adler AG 0791 100632 EN ...
Страница 24: ......