background image

Contatto

ModDMX

Correct disposal of the product (waste electrical & electronic 
equipment)

(Applicable   in   the   European   Union   and   other 
European   countries   with   separate   collection   sys-
tems). This marking on the product, accessories or 
documentation   indicates   that   the   product   and   its 
electronic   accessories   should   not   be   disposed   of 
with other household waste at the end of their work-

ing life. To prevent possible harm to the environment or human 
health   from   uncontrolled   waste   disposal,   please   separate   these 
items from other types of waste and recycle them responsibly to 
promote the sustainable reuse of material resources. 
Household users should contact either the retailer where they pur-
chased this product, or their local government office, for details of 
where and how they can take these items for environmentally safe 
recycling. Business users should contact their supplier and check 
the terms and conditions of the purchase contract. Adequate dis-
posal  of the decommissioned equipment for recycling, treatment 
and environmentally compatible disposal contributes in preventing 
potentially negative effects on the environment and health and pro-
motes the reuse and/or recycling of equipment materials. Abusive 
product disposal by the user is punishable by law with administrat-
ive sanctions.

Installation and use restrictions 
Standards and regulations

The design and the setting up of electrical systems must be per-
formed according to the relevant standards, guidelines, specifica-
tions   and   regulations   of   the   relevant   country.   The   installation, 
configuration and programming of the devices must be carried out 
by trained personnel.
The installation and the wiring of the 

Contatto

 bus line and the re-

lated devices must be performed according to the recommenda-
tions of the manufacturers (reported on the specific data sheet of 
the product) and according to the applicable standards.
All the relevant safety regulations, e.g. accident prevention regula-
tions, law on technical work equipment, must also be observed.

Safety instructions

Protect the unit against moisture, dirt and any kind of damage dur-
ing transport, storage and operation.
Do not operate the unit outside the specified technical data.
Never open the housing. If not otherwise specified, install in closed 
housing (e.g. distribution cabinet).
Earth the unit at the terminals provided, if existing, for this purpose.
Do not obstruct cooling of the units.

Setting up

The physical address must be assigned with the specific program-
mer and the setting of parameters (if any) must be performed by 
the specific configuration softwares; for more details refer to the 
specific data sheet of the product. For the first installation of the 
device, generally and  unless  otherwise specified on the specific 
data   sheet   of   the   product,   proceed   according   to   the   following 
guidelines:

Check that any voltage supplying the plant has been removed

Assign the address to module (if any)

Install  and  wire the device according  to the schematic  dia-
grams on the specific data sheet of the product

Only then switch on the 230Vac supplying the bus power sup-
ply and the other related circuits

Applied standards

The devices belonging to  

Contatto

  line comply with the essential 

requirements of the following directives:
2004/108/CE (EMC)
2006/95/CE (Low Voltage)
2002/95/CE (RoHS)

Note

Technical characteristics and this data sheet are subject to change 
without notice.

DUEMMEGI

 s.r.l. - Via Longhena, 4 - 20139 MILANO

Tel. 02/57300377 - Fax 02/55213686 – 

www.duemmegi.it

Rel.: 2.2 December 2013

Page 7 of 7

HOME AND BUILDING AUTOMATION

Содержание Contatto ModDMX

Страница 1: ...o the bus terminal block shows that the module is supplied while a yellow LED near to the 3 way terminal block shows the presence of communication on the DMX line ModDMX is housed in a standard DIN 3M...

Страница 2: ...aved if the low byte is 0 then all channels will be included 103 0x67 Exclude the channel specified by the low byte in the next scenery that will be saved if the low byte is 0 then all channel will be...

Страница 3: ...ng Up Down pushbuttons pushing and holding Up Down button the brightness increases decreases until the max min value is reached When the brightness has reached the desired level release the button to...

Страница 4: ...es Set minimum and maximum value The commands 135 and 136 0x87 and 0x88 allow to set a minimum and a maximum value on all DMX channel for the functions Up Down and Single Command Broadcast command The...

Страница 5: ...hannel and to the following two The just seen RGB assignment allows to easily set on the RGB spot the desired color chosen on the color palette that will be opened by clicking on the colored square un...

Страница 6: ...ModDMX which is communicating with MCP Ide Code is the value of the code to be sent to to ModDMX module high byte of the Word to be sent see the bus com mand table Val Sc Ch is the value or the scene...

Страница 7: ...e Contatto bus line and the re lated devices must be performed according to the recommenda tions of the manufacturers reported on the specific data sheet of the product and according to the applicable...

Отзывы: