7
its lower part. Do not store small objects
or pieces of paper in the drawer found
under the hob, since they could break
the fan and affect cooling in case they
are sucked. There must be a minimum
distance of 2cm between the drawer
contents and the fan inlet.
INSTALLATION INSTRUCTIONS
These installation instructions are
intended for a specialized installer
and are meant as guidelines for the
hob installation, adjustment and
maintenance, in compliance with any
regulations and standards in force. If
a built-in oven or any other appliance
generating heat is to be mounted directly
under the vitro-ceramic hob,
IT IS
NECESSARY THAT SUCH AN APPLIANCE
(the oven) AND THE VITRO-CERAMIC
HOB ARE PROPERLY INSULATED
. Failure
to comply with this precaution might
result in the incorrect operation of the
TOUCH CONTROL system.
POSITIONING
This household appliance has been de-
signed for built –in installation onto a
worktop, as shown in the figure (Fig.2).
Use sealing material along the whole
perimeter - Fig.4 (Cut dimensions-
Fig.2). This operation is necessary in
order to prevent any liquid from entering
inside the hob, being that the flatness
of the top, the glass and their coupling
cannot be assured. Fix the appliance
on the worktop by using the 4 supports,
taking the work top thickness into ac-
count (Fig.2). If, after installation, the
lower part of the appliance is accessible
from the lower part of the cabinet, it will
be necessary to mount a spacing panel
at the distances given (Fig.3). If the ap-
pliance is installed under an oven, this
step will not be necessary. The appli-
ance is not intended to be operated by
an external timer or a separate remote
control system.
VENTILATION
(Fig.5)
The distance between the cooktop and
built-in kitchen’s furnitures or cooking
apparatuses must guarantee sufficient
ventilation of the air. Not to use the
cooktop if in the oven is in course the
pyrolysis process.
ELECTRIC CONNECTIONS
(Fig.7)
Before carrying out any electric
connections, please make sure that:
- the ground electric cable is 2 cm. longer
than the other cables;
-
the electrical system meets any
requirement mentioned in the rating
label found on the underside of the
work top;
- the electrical system is equipped with
an efficient grounding system and
compliant with any standards and law
directives in force.
In the case the appliance is not equipped
with a power cord and/or the related
plug, please use a material suitable for
the power absorption value mentioned
in the rating label and for the operating
temperature. If a direct connection to
the electric network is required, you
need to use an omnipolar power switch
with a switch-contact gap of at least 3
mm, suitable for the value mentioned
in the label, and compliant with the
related standards in force (the yellow/
green ground connection shall not be
interrupted by the change-over switch).
Once the appliance installation is
completed, the omnipolar switch shall be
easily accessible.
WARNING! THIS APPLIANCE MUST
BE GROUNDED
Содержание MH-F3BS
Страница 1: ...C MIXED INDUCTION HI LIGHT VITROCERAMIC HOB MH F3BS User Instructions...
Страница 2: ...2 A D E F G C C B D1 Fig 1...
Страница 4: ...4 Fig 6 Fig 5...
Страница 12: ...3PCLIOBIH600TDD 15 novembre 2016...