
36
8.2.6 Overload current protection diagnosis and solution(F0)
Error Code
F0
Malfunction decision
conditions
An abnormal current rise is detected by checking the specified
current
detection circuit.
Supposed causes
●
Power supply problems.
●
System blockage
●
PCB faulty
●
Wiring mistake
●
Compressor malfunction
Trouble shooting:
Check the power supply. Is it
normal?
Is there any blocking?
Check the compressor resistance
values. Is it normal?
Check the connections and wires.
Is everything well connected?
Check the reactor. Is it normal?
Stop the unit. Check the power
supply.
Clear the blockage.
Replace the compressor.
Correct the connections or
replace the wires.
Replace the reactor.
Replace the outdoor main PCB.
No
No
No
No
No
Yes
Yes
Yes
Yes
Yes
Содержание DA1221-H2-I
Страница 1: ...DuctlessAire ES Series Service Manual 2016 ABSSA B4 1601 ...
Страница 8: ...6 For DA1221 H2 I For DA1821 H2 I DA2421 H2 I ...
Страница 10: ...8 For DA1221 H2 O ...
Страница 11: ...9 For DA1821 H2 O ...
Страница 12: ...10 For DA2421 H2 O ...
Страница 13: ...11 4 Refrigerant Cycle Diagram ...