84
ENGLISH
3B.
RF (wireless communication)
RF components (
) have a maximum free-field range of 350 metres.
This distance will be much less in a building because of obstacles
so you will need to allow for features such as walls, concrete and
metal. All slave components (except those which are battery powered)
also act as repeaters. Signals from components that are unable to
make a (strong) connection with the master component are for-
warded automatically via no more than one other non-battery-pow-
ered component (= hop point). Please refer to information sheet
at www.duco.eu for further information.
DUCO RF
Power supply
230 VAC
Frequency
868 MHz
Maximum distance
350 m, free field
(less through obstacles)
Maximum number
of components
Up to 25 wireless components in a single system