The method is as following:
a.
Put the press in inch mode, then adjust the slide to the lowest point(180°).
b.
Use the same steps as 5.5.1 to enter the system menu.
c.
Now the quaternion digital monitor upside will flash. Press
or to select the
menu. Choose P03 and press
to enter it.
d.
It displays 180 and flashes. Press
to stop it from flashing.
e.
Press
to back to the main menu. Press the key once more it will exit the setting
process. At last the system will save the data automatically. The setting is over.
5.5.6 Counts setting
Count the work of counter-point perspective, the system is set to 135 degrees (can be
customized)
5.5.7 Other parameter of controller
P11-P12 is read-only. Adjust it to the corresponding menu. It displays the data. You can not
change it.
P11------- Electricity times on controller, which used to estimate the time controller has
worked.
P12------- Controller software edition number
The method is as following:
a. Use the same steps as 5.5.1 to enter the system menu
b. Now the quaternion digital monitor upside will flash. Press or to select the
menu. Choose P11 to P12 the digital displayer will display the corresponding data.
c. Press
to exit the setting.
5.5.8 The production count arriving function
1. The system menu of the F06 function for the production of the second count of options to
reach a maximum count value is 999999;
2. When the count reaches the production of F06 to set a value of "0" when the count reaches
the production is turned off; F06 setting does not affect the way that the output is "cutting the
output cam."
3. When the set count reaches the value of the production of F06 is not "0" when the count
reaches the production function of opening, F06 channel into a count to reach the output.
4. F06 to set the menu items into the system, with key switch counts the number of bits, and
then adjust the count, or key, set up, press to confirm and exit automatically saved.
5. Count arrived, in the last ending point (0 degrees), the output signal, F06 channel, a long
bright light, blinking count, the system stops working, press reset button cleared and re-start
work; work halfway through the count is cleared , its function will be back to work.
17
VI Protection and alarm
6.1 Protection And Alarm Instruction
The controller will shut off system ‘Ready’ signal and output ‘Stop’ signal when it
inspects the unusual. System will display the corresponding unusual code.
6.2Protection and trouble codes
:
Caution
:
When it alarms, please eliminate the troubles at first and then eliminate the
alarm.
Press enter key or input the alarm reset signal to eliminate the alarm.
Code Description Unusual
Reason
Eliminate
Method
E01
Main Memory
Unusual
Power
、
Chip
Replace
controller
E02
Sub Memory
Unusual
Power
、
Chip
Replace
controller
E03
CPU Unusual
CPU Chip
Replace
E05
Brake Out Put
Unusual
Brake Circuit,
Redundancy
Protection
Replace
controller
E06 Sensor
Unusual
Wiring Unusual
or Damaged
Check rotary
transducer
E08
RS485
Wiring Unusual
Check
E09
RS485
Wiring Unusual
18