Ducasa Sunrise Eco-Pro SR03D-EP Скачать руководство пользователя страница 5

min. 75mm

min. 150mm

d = min. 10mm

s

s<40mm. → d=min 10mm

min. 75mm

min. 150mm

d = min. 200mm

s

s>40mm. → d=min 200mm

if shelf (s) is less than 40mm.

minimum distance(d) from heater 10mm.

if shelf (s) is more than 40mm.

minimum distance(d) from heater 200mm.

 

centres for

screw hooks

‘L’ Shaped Bracket

895mm.

5

INSTALLATION

Select a suitable position on a wall, near to a mains power socket (but not directly below it) making sure 

there is at least 75mm below and 10mm above the heater of unobstructed space if the window sill protrudes 

less than 40mm. If the sill protrudes more than 40mm then space required above is 200 mm.”

Fix the two screw hooks to the wall at measured centres of 895mm.

Locate the appliance over the top of the screw hooks and allow it to hang in place.

Fit the bottom ‘L’ shaped bracket onto the wall and then secure the heater by screwing the small screw 

directly into the underside of the grill.

The cable comes out from the right hand side of the heater and measures approximately 1.6m.

USING THE HEATER

Before switching on, ensure that all packaging items are removed and that the heater is wall mounted 

correctly otherwise damage may occur.

Plug in and switch on at wall socket.
The element has been coated with a protective film, which will burn off during the first few minutes and may 

cause a small amount of fuming. This is quite normal – the fumes are non-toxic and will quickly disappear. We 

recommend that you open a window to ventilate the room when using the heater for the first time.

You may notice some parts of the element appearing to be hotter from time to time because of the variable 

airflow through the heater. This does not cause a safety hazard.

The heater grille may become discoloured with use – this is a caused by airborne pollution and is not a fault.

Содержание Sunrise Eco-Pro SR03D-EP

Страница 1: ...mable Low Level Radiant Panel Heater Class II Rated Appliance NOTE A qualified electrician must carry out the electrical installation of this product The electrical installation must comply with the c...

Страница 2: ...STICS 7 ADJUST PROGRAMMED TEMPERATURES 7 SETTING PROGRAMME AND CLOCK 8 KEYPAD LOCKING ANTI TAMPER 8 ADVANCED SETTINGS 8 Degrees Fahrenheit or Celsius C1 9 Type of Control C2 9 Temperature Compensation...

Страница 3: ...minder to the user ATTENTION The heaters must not be covered by clothing containers or any other objects that may block the air ventilation VERY IMPORTANT The OFF indicator shown on the heater s contr...

Страница 4: ...lace the heater directly on the floor Make sure that the wall where the heater is going to be mounted is suitable to bear the heater s weight Use the correct fixing for the type of wall the heater is...

Страница 5: ...o the wall and then secure the heater by screwing the small screw directly into the underside of the grill The cable comes out from the right hand side of the heater and measures approximately 1 6m US...

Страница 6: ...20 minutes the clock information will be lost When powered on for the first time the heater starts in the OFF mode When powered on after the initial start up it will return to the last mode it was in...

Страница 7: ...room temperature is lower than the set temperature the heating symbol will be shown indicating that the heater is producing heat When the room temperature equals or is above the set temperature the h...

Страница 8: ...K button Next select the hour and confirm with OK button and then select the minutes and confirm pressing OK button once more KEYPAD LOCKING ANTI TAMPER The keypad can be locked to prevent any unautho...

Страница 9: ...C and hysteresis of 0 75 C To change the type of control press Confirm with the OK button The screens shown are Temperature Compensation C3 In this mode the display will alternate between the temperat...

Страница 10: ...icular time The heater will monitor the room temperature over 10 days to establish how quickly the room reaches temperature and uses this information to switch the heater on at the correct time By rea...

Страница 11: ...ode OFF Comfort Temp 19 C Economy Temp 17 C Frost Protection Temp 5 C Manual Mode Temp 19 C Temperature Compensation 0 C Temperature Units C Control Type PID Default Programme All Economy Open Window...

Страница 12: ...heat output elmax 0 00037 kW At minimum heat output elmin 0 00037 kW In standby mode elSB 0 00037 kW Type of heat output room temperature control Electronic room temperature control plus week timer Ot...

Страница 13: ...13 QUICK GUIDE TO MANUAL PROGRAMMING...

Страница 14: ...14 Installation Notes...

Страница 15: ...15 Installation Notes...

Страница 16: ...supplier Correct Disposal of This Product Waste Electrical Electronic Equipment Applicable in the European Union and other European countries with separate collection systems This marking shown on the...

Отзывы: