13
Runback Config
Setback
Max. Temp.
Runback
Runback Config.
OFF
ON
Settings
Runback
Status ON
Change
Password
Status
ON
OFF
Password
Status ON
Change
Password
CONFIRM NEW
PASSWORD
1 2 3 4 OK
ENTER
PASSWORD
- - - - OK
PASSWORD
The Password Function of the towel rail serves
a number of functions; Keylock, Advanced menu
access and also Runback access when the
Runback is activated. The Default password from
the factory is four zero’s (0 0 0 0), however it is
strongly recommended
that once installation is
complete that an alternative code is set.
To access the password function enter the
ADVANCED SETTINGS menu (see above) and
then select PASSWORD.
The password can be turned on or off and
changed.
To turn the password on or off, select Status
using +/- button and press
Mode/OK
.
Select either “ON” or “OFF” and press
Mode/
OK
.
If you are reactivating the password then the
Enter New password screen is shown (The
password will always default back to 0 0 0 0).
If the password is turned off, the Keylock,
Advanced Settings menu and Runback controls
are accessible without entering a password.
To Change the password code when the
password is active select Change from the
password screen and using +/- button and press
Mode/OK
.
Enter the new password using +/- buttons and
Mode/OK
to confirm the new number. Once “OK”
is highlighted press
Mode/OK
.
RUNBACK MODE
The towel rail comes with a Runback mode for
use when the heater will be installed in areas
where restricted user control is required.
When Runback Mode is active it allows the user
to set the towel rail to run for a specific pre-set
amount of time and temperature. It is also possible
to set a maximum temperature (Max Temp) above
the Runback setting to allow the user to increase
the temperature within the limits allowed.
Before activating Runback mode it is strongly
recommended that an alternative password is set
and activated and the comfort mode temperature
set-point is set to 35°C. When the password is
activated the user will have no access to any
towel rail settings without the password.
NOTE: Any display settings will be used in
RUNBACK mode, eg. Backlight time and intensity,
Eco mode etc. These should be adjusted prior to
setting Runback to Active.
After the Runback time period ends the room
temperature will return to off (7°C minimum) until
the Runback is restarted.
It is also possible to set a minimum temperature
to be maintained (Setback) outside of the Runback
mode; when setback mode is activated the room
temperature will only fall as low as the Setback
temperature. The temperature will be maintained
at this point until Runback is restarted.
ACTIVATING RUNBACK MODE
Runback mode is activated
from the Advanced settings
menu.
The main Runback screen
has 3 options:
•
Runback Config
•
Setback Config
•
Max Temp
Set Runback to ON to
activate the mode.
Note: The Runback settings menu is not
available unless the Runback mode has been
turned on.