4AC13 Split System Air Conditioner
13
Outdoor
Model
Indoor Model
SEER
EER
Rated
ARI
Capacity
1
Rated
Sensible
Capacity
CFM
Refrigerant
Connection
Refrigerant
Line Size
Indoor Metering
Device
Piston or Field
Installed TXV
Factory
Installed
TXV
Outdoor
Indoor
Suction
Liquid
Req'd
Indoor
2
Optional
Indoor
Suction
Liquid
Suction
Liquid
4AC13(B,L)18
RBCS2M18C****P
-
13.00
11.50
18,100
13,000
600
3/4 3/8 3/4 3/8
3/4
3/8
0.053
A4TXV01
RBCS2M24V****P
-
14.00
12.00
18,300
13,200
600
3/4 3/8 3/4 3/8
3/4
3/8
0.053
A4TXV01
4AC13(B,L)24
RBCS2M24C****T
-
13.50
11.00
23,000
16,600
750
3/4 3/8 3/4 3/8
3/4
3/8
0.057
A4TXV01
RBCS2M24V****P
-
14.00
11.50
23,200
16,700
750
3/4 3/8 3/4 3/8
3/4
3/8
0.057
A4TXV01
4AC13(B,L)30
RBCS2M30C****P
-
13.50
11.00
28,200
21,200
1000
3/4 3/8 3/4 3/8
3/4
3/8
0.062
A4TXV01
RBCS2M36V****P
-
14.00
12.00
28,600
21,500
1000
3/4 3/8 3/4 3/8
3/4
3/8
0.062
A4TXV01
4AC13(B,L)36
RBCS2M36C****T
-
13.50
11.50
34,200
25,300
1200
3/4 3/8 3/4 3/8
3/4
3/8
0.065
A4TXV02
RBCS2M36V****P
-
14.00
12.00
34,400
25,500
1200
3/4 3/8 3/4 3/8
3/4
3/8
0.065
A4TXV02
4AC13(B,L)42
RBCS2M42****P
-
13.50
11.00
39,500
29,600
1400
7/8 3/8 7/8 3/8
7/8
3/8
0.074
A4TXV02
RBCS2M42V****P
-
14.00
11.50
40,000
30,000
1400
7/8 3/8 7/8 3/8
7/8
3/8
0.074
A4TXV02
4AC13(B,L)48
RBCS2M48****P
-
13.50
11.00
47,000
33,400
1550
7/8 3/8 7/8 3/8
7/8
3/8
0.082
H4TXV03
RBCS2M48V****P
-
14.00
11.50
47,500
33,700
1550
7/8 3/8 7/8 3/8
7/8
3/8
0.082
H4TXV03
4AC13(B,L)60
RBCS2M60****P
-
13.00
11.00
56,000
39,800
1750
7/8 3/8 7/8 3/8 1-1/8
3/8
0.090
H4TXV03
RBCS2M60V****P
-
13.50
11.00
56,500
40,100
1750
7/8 3/8 7/8 3/8 1-1/8
3/8
0.090
H4TXV03
Cooling Performance with Air Handlers and Furnaces
1
Certified in accordance with Unitary Air Conditioner Certification Program, which is based on ARI Standard 210/240.
2
Required to achieve ARI rating.