2AC14 Split System Air Conditioner
14
2
AC
14
B
36
P
-
1
A
Model Number Guide
Refrigerant – 2 = R22
AC = Split Condensing
Unit
14 - 14 SEER Nominal
B = Wire Guard
L = Louvered
BC = Wire Guard + 76dBA
LC = Lo 76dBA
Minor Revision Code
Major Revision Code
Voltage
P - 208-230v/60hz
Nominal Capacity
36 - 36,000 Btuh
Model
Voltage/ Hz/
Phase
Voltage
Range
Min.
Circuit
Amp.
Maximum
Over
Current
Device
(amps)
Compressor
Fan Motor
Refrig.
Charge
(oz.)
:
Weight (lbs.)
Rated
Load
(Amps)
Locked
Rotor
(Amps)
Full Load
Amps
Rated
HP
Nom.
RPM
Wire Guard/
Louvered
2AC14**18P
208-230/60/1
197 - 253
9.7
15
6.9
35
1.1
1/10
1075
106
185
2AC14**24P
208-230/60/1
197 - 253
11.6
20
8.4
39
1.1
1/10
1075
129
201
2AC14**30P
208-230/60/1
197 - 253
15.2
25
11.3
51
1.1
1/5
1075
154
227
2AC14**36P
208-230/60/1
197 - 253
17.2
30
12.9
61
1.1
1/5
1075
165
226
2AC14*42P
208-230/60/1
197 - 253
21.5
35
16.2
82
1.2
1/4
1075
204
262
2AC14*48P
208-230/60/1
197 - 253
22.6
35
17.1
100
1.2
1/4
1075
208
261
2AC14*60P
208-230/60/1
197 - 253
28.8
50
21.4
137
2.0
1/3
1075
264
270
Electrical and Physical Data
:
Factory charged for 15 feet of line set. Adjust per Installation Instructions
** = B, L, BC, LC
* = B, L
Dimensions (in.) and Sound Ratings
Model
Dimensions
B, L
Sound Rating
(dBa)
BC, LC
Sound Rating
(dBa)
A - width
(in.)
B - depth
(in.)
C - height
(in.)
2AC14**18P
30
30
25.5
80
76
2AC14**24P
30
30
25.5
80
76
2AC14**30P
30
30
33.5
79
76
2AC14**36P
30
30
33.5
80
76
2AC14*42P
30
30
41.5
76
---
2AC14*48P
30
30
41.5
78
---
2AC14*60P
30
30
41.5
80
---
** = B, L, BC, LC
* = B, L