INSTALLATION

INSTALLATION

Wall, Ceiling or Pole Mounting

Pole Mounting

1.   Loosen the three captive screws on the clear cover.

2.   Remove cover. (all models without clear cover skip step 1 & 2)

3    Rotate lamp heads to desired position.

4.   Loosen set screws 2 per head and adjust axially on stem.

5.   Lock set screws once desired position is set (hex wrench provided).

6.   Reverse steps 2 &1 (if required).

NOTE: IF UNIT IS IN A WET LOCATION 

ENVIRONMENT, ALL COVER SCREWS 

ARE TO BE TORQUED TO 5-6 INCH 

POUNDS OR UNTIL COVER SEATS WITH 

HOUSING!

“DO NOT OVER TIGHTEN SCREWS” 

7X PLCS

DYN Wiring Diagram

Lamp Head Adjustment

93055897

93061887

93055892

93055893

93055812

***Once remote capacity base models DYN12 or DYN12I have been installed press and 

hold the test button for more than 5 seconds to initiate the “LOAD LEARN” process.***

“AC ON” LED is illuminated when AC power is present.

NOTE: All models are supplied with an AC Lockout circuit, which prevents the emergency lights from illuminating when the 

battery is connected and no AC power is present.

NOTE: All models are supplied with Low Voltage Disconnect circuit, which prevents damage to the battery from deep discharge 

during prolonged emergency operation.

NOTE: Batteries are often shipped in a discharged state – this is normal. The battery will require charging. Allow 24 hours of 

charging before testing the unit.

Models without SPECTRON

®

 Self-Diagnostic

Models without Spectron

®

 self diagnostic electronics system provide:

  • Visual indication of AC power status  

Visual indication of any unit malfunctions include –

  •  Battery Disconnected  

  •  Charger Fault

Models with SPECTRON

® 

Self-Testing/Self-Diagnostic Circuitry

Models equipped with the Spectron

®

 self-testing/self-diagnostic electronics system provide:

  •  Visual indication of AC power status  

  •  Visual indication on self-diagnostic status and results

Visual indication of any unit malfunctions include –

  •  Battery Disconnected 

  •  Battery Fault  

  •  Charger Fault 

  •  LED Driver Fault 

  •  Lamp Fault 

  •  Load Learn Failure

Spectron equipped units also include:

Browout protection: Unit will automatically transfer to emergency operation upon detection of low AC power 

(approximately 80% of nominal line.)

Time Delay Retransfer: upon return of normal AC power, unit will remain in emergency mode for an additional 

15 minutes to allow AC power to stabilize. 

OPERATION

1.   The DYN mounting plate can be mounted directly to a wall, ceiling or 

      pole (using appropriate hardware). 

2.   Once mounting plate is secured, you can hang the DYN Industrial Unit 

and add security screws (qty 4).

3.   If the DYN unit is mounted to the ceiling the 4 security screws are to be 

added to keep the unit secure to the mounting plate.

4.   Feed the AC power leads through the hub assembly (provided). 

Hubs are provided with ground lug for entrance of AC power supply. 

Following final conductor routing, use a thread sealant in the conduit-to 

hub joint to maintain maximum environmental protection. Note: hub(s) 

must be grounded.

5.   Install and connect Listed remote lighting fixture(s) (if applicable). Note 

connections on the wiring diagram in this document. Note: hub(s) must 

be grounded.

6.   Only use UL Listed water tight conduit fittings that meet the 

      requirements of the UL 514B Standard for Conduit Tubing and Cable 

      Fittings when using (K.O.’s see note 5).

7.   Connect wire from the unit to the building leads and secure with 

      wire nuts.

8.   For remote capable DYN models, cut ORANGE wire connector from  

   orange remote leads and strip ½ inch for both lead ends. Observe  

   proper polarity when connecting remote leads to remote fixtures. 

   Pos. (+) to red remote fixture lead and Neg. (-) to black remote 

   fixture lead.

9.   Connect battery pack harness to PCB charger harness.

10.

 For pole mounting used additional #8‐32 x ¼ long screws (qty 2) and 

      both toothed mounting brackets as shown. Banding straps are not 

      provided due to varying pole and column dimensions.

93055895

4

3

D

C

B

A

4

3

2

1

D

C

B

A

1

2

REV

DATE

RECORD

DESN CHCK

C

CRITICAL DIMENSIONS

UNSPECIFED TOLERANCES:    INCHES

X.X=

u

0.02   X.XX=

u

0.01   X.XXX=

u

0.005

FRACTIONS=

u

1/32   ANGULAR TOLERANCE=

u

.5

v

CATALOG NO.

ENGINEERING:

CHECKED BY:

THIRD ANGLE PROJECTION

DRAWN BY:

DO NOT SCALE PRINT

CONFORMS TO ASME Y14.5M

DIMENSIONS IN [ ] IN MM

DIMENSIONS IN INCHES

This document contains confidential and proprietary information of Dual

Lite. Receipt or possession of this document does not convey any rights to

reproduce or disclose its contents, or to make, use , or sell anything it may

disclose. Reproduction, disclosure, or use of the document or its contents,

without the specific written authorization of Dual Lite, may violate the

intellectual property rights of Dual Lite.

MATERIAL:

FINISH:

PART NO.

SCALE

SIZE DRAWING NO.

REV.

SHT 1

1 SHTS

---

93055812

93055812

2

ILL-WIRING DIA DYN

ABrunelli 05/07/15

ALB

6/12/14

---

ALB

6/12/14

1:1

ALB

EC-121017003

6/12/14

1

ALB

---

ALB

ADDED WAGO ,EC-121017003

5/7/15

2

ALB

THIS ILLUSTRATION IS USED ON INSTRUCTION SHEET 93048898

ORG 

(POS +)

ORG 

(NEG -)

R

EM

O

TE

LEAD

 (-)

R

EM

OT

E

LEAD

 (+

)

 ORG

 WIRE

CONN.

BLK (NEG -)

RED (POS +)

BLK (NEG -)

RIBBON 

CABLE

SWITCH/LED PCB

CHARGER PCB

J2

J6

J5

J10

J9

HEATER

HARNESS

(IF REQ)

WHT (COM)

BLK (HOT)

AC INPUT

BATTERY

HARNESS

HEATER/BATTERY

          PACK

RED (POS +)

AC2 AC1

3

4

D

C

B

A

3

4

1

2

D

C

B

A

1

2

REV

DATE

RECORD

DESN CHCK

C

CRITICAL DIMENSIONS

UNSPECIFED TOLERANCES:    INCHES

X.X=

u

0.02   X.XX=

u

0.01   X.XXX=

u

0.005

FRACTIONS=

u

1/32   ANGULAR TOLERANCE=

u

.5

v

CATALOG NO.

ENGINEERING:

CHECKED BY:

THIRD ANGLE PROJECTION

DRAWN BY:

DO NOT SCALE PRINT

CONFORMS TO ASME Y14.5M

DIMENSIONS IN [ ] IN MM

DIMENSIONS IN INCHES

This document contains confidential and proprietary information of Dual

Lite. Receipt or possession of this document does not convey any rights to

reproduce or disclose its contents, or to make, use , or sell anything it may

disclose. Reproduction, disclosure, or use of the document or its contents,

without the specific written authorization of Dual Lite, may violate the

intellectual property rights of Dual Lite.

MATERIAL:

FINISH:

PART NO.

SCALE

SIZE DRAWING NO.

REV.

SHT 1

1 SHTS

---

93055892

93055892

1

ILL-CLEAR CVR DYN

ALB

06/16/14

ALB

6/12/14

ALB

6/12/14

1:2

ALB

EC-121017003

6/12/14

1

ALB

---

THIS ILLUSTRATION IS USED ON INSTRUCTION SHEET 93048898

4

3

D

C

B

A

4

3

2

1

D

C

B

A

1

2

REV

DATE

RECORD

DESN CHCK

C

CRITICAL DIMENSIONS

UNSPECIFED TOLERANCES:    INCHES

X.X=

u

0.02   X.XX=

u

0.01   X.XXX=

u

0.005

FRACTIONS=

u

1/32   ANGULAR TOLERANCE=

u

.5

v

CATALOG NO.

ENGINEERING:

CHECKED BY:

THIRD ANGLE PROJECTION

DRAWN BY:

DO NOT SCALE PRINT

CONFORMS TO ASME Y14.5M

DIMENSIONS IN [ ] IN MM

DIMENSIONS IN INCHES

This document contains confidential and proprietary information of Dual

Lite. Receipt or possession of this document does not convey any rights to

reproduce or disclose its contents, or to make, use , or sell anything it may

disclose. Reproduction, disclosure, or use of the document or its contents,

without the specific written authorization of Dual Lite, may violate the

intellectual property rights of Dual Lite.

MATERIAL:

FINISH:

PART NO.

SCALE

SIZE DRAWING NO.

REV. SHT 1

1 SHTS

---

93055893

93055893

1

ILL-HD ADJ DYN

ALB

06/12/14

ALB

6/12/14

ALB

6/12/14

2:1

ALB

EC-121017003

6/12/14

1

ALB

---

THIS ILLISTRATION IS USED ON INSTRUCTION SHEET 93048898

4

3

D

C

B

A

4

3

2

1

D

C

B

A

1

2

REV

DATE

RECORD

DESN CHCK

C

CRITICAL DIMENSIONS

UNSPECIFED TOLERANCES:    INCHES

X.X=

u

0.02   X.XX=

u

0.01   X.XXX=

u

0.005

FRACTIONS=

u

1/32   ANGULAR TOLERANCE=

u

.5

v

CATALOG NO.

ENGINEERING:

CHECKED BY:

THIRD ANGLE PROJECTION

DRAWN BY:

DO NOT SCALE PRINT

CONFORMS TO ASME Y14.5M

DIMENSIONS IN [ ] IN MM

DIMENSIONS IN INCHES

This document contains confidential and proprietary information of Dual

Lite. Receipt or possession of this document does not convey any rights to

reproduce or disclose its contents, or to make, use , or sell anything it may

disclose. Reproduction, disclosure, or use of the document or its contents,

without the specific written authorization of Dual Lite, may violate the

intellectual property rights of Dual Lite.

MATERIAL:

FINISH:

PART NO.

SCALE

SIZE DRAWING NO.

REV. SHT 1

1 SHTS

---

93055895

93055895

1

ILL-TEST AC ON DYN

ALB

06/12/14

ALB

6/12/14

---

ALB

6/12/14

1:1

ALB

EC-121017003

6/12/14

1

ALB

---

THIS ILLISTRATION IS USED ON INSTRUCTION SHEET 93048898

4

3

D

C

B

A

4

3

2

1

D

C

B

A

1

2

REV

DATE

RECORD

DESN CHCK

C

CRITICAL DIMENSIONS

UNSPECIFED TOLERANCES:    INCHES

X.X=

u

0.02   X.XX=

u

0.01   X.XXX=

u

0.005

FRACTIONS=

u

1/32   ANGULAR TOLERANCE=

u

.5

v

CATALOG NO.

ENGINEERING:

CHECKED BY:

THIRD ANGLE PROJECTION

DRAWN BY:

DO NOT SCALE PRINT

CONFORMS TO ASME Y14.5M

DIMENSIONS IN [ ] IN MM

DIMENSIONS IN INCHES

This document contains confidential and proprietary information of Dual

Lite. Receipt or possession of this document does not convey any rights to

reproduce or disclose its contents, or to make, use , or sell anything it may

disclose. Reproduction, disclosure, or use of the document or its contents,

without the specific written authorization of Dual Lite, may violate the

intellectual property rights of Dual Lite.

MATERIAL:

FINISH:

PART NO.

SCALE

SIZE DRAWING NO.

REV. SHT 1

1 SHTS

---

93055897

93055897

1

ILL-WIRE ROUTING DYN

ALB

06/12/14

ALB

6/12/14

ALB

6/12/14

1:1

ALB

EC-121017003

6/12/14

1

ALB

---

THIS ILLISTRATION IS USED ON INSTRUCTION SHEET 93048898

4

3

D

C

B

A

4

3

2

1

D

C

B

A

1

2

REV

DATE

RECORD

DESN CHCK

C

CRITICAL DIMENSIONS

UNSPECIFED TOLERANCES:    INCHES

X.X=

u

0.02   X.XX=

u

0.01   X.XXX=

u

0.005

FRACTIONS=

u

1/32   ANGULAR TOLERANCE=

u

.5

v

CATALOG NO.

ENGINEERING:

CHECKED BY:

THIRD ANGLE PROJECTION

DRAWN BY:

DO NOT SCALE PRINT

CONFORMS TO ASME Y14.5M

DIMENSIONS IN [ ] IN MM

DIMENSIONS IN INCHES

This document contains confidential and proprietary information of Dual

Lite. Receipt or possession of this document does not convey any rights to

reproduce or disclose its contents, or to make, use , or sell anything it may

disclose. Reproduction, disclosure, or use of the document or its contents,

without the specific written authorization of Dual Lite, may violate the

intellectual property rights of Dual Lite.

MATERIAL:

FINISH:

PART NO.

SCALE

SIZE DRAWING NO.

REV.

SHT 1

1 SHTS

---

3061887

93061887

1

ILL-POLE MTG DYN

ALB

03/02/15

ALB

6/12/14

---

ALB

6/12/14

1:1

ALB

EC-121017003

10/7/14

1

ALB

---

THIS ILLISTRATION IS USED ON INSTRUCTION SHEET 93048898

BANDING STRAP SLOT

8X PLCS 1 X 1/4 INCH

HARDWARE HOLE

8X PLCS 5/16 DIA.

TYPICAL BANDING STRAPS,

NOT PROVIDED

7

8

5
6

9

10

1

3

1

2

93055896

3

4

D

C

B

A

3

4

1

2

D

C

B

A

1

2

REV

DATE

RECORD

DESN CHCK

C

CRITICAL DIMENSIONS

UNSPECIFED TOLERANCES:    INCHES

X.X=

u

0.02   X.XX=

u

0.01   X.XXX=

u

0.005

FRACTIONS=

u

1/32   ANGULAR TOLERANCE=

u

.5

v

CATALOG NO.

ENGINEERING:

CHECKED BY:

THIRD ANGLE PROJECTION

DRAWN BY:

DO NOT SCALE PRINT

CONFORMS TO ASME Y14.5M

DIMENSIONS IN [ ] IN MM

DIMENSIONS IN INCHES

This document contains confidential and proprietary information of Dual

Lite. Receipt or possession of this document does not convey any rights to

reproduce or disclose its contents, or to make, use , or sell anything it may

disclose. Reproduction, disclosure, or use of the document or its contents,

without the specific written authorization of Dual Lite, may violate the

intellectual property rights of Dual Lite.

MATERIAL:

FINISH:

PART NO.

SCALE

SIZE DRAWING NO.

REV.

SHT 1

1 SHTS

---

93055896

93055896

1

ILL-WALL MTG BRKT

ALB

06/12/14

ALB

6/12/14

---

ALB

6/12/14

1:2

ALB

EC-121017003

6/12/14

B

L

A

1

---

THIS ILLISTRATION IS USED ON INSTRUCTION SHEET 93048898

Drill "W" (.397 dia)

UNIT CAN BE THREADED ROD MOUNTED

3/8 THREADED ROD IS RECOMMENDED

1

5

2

3

6

4

7

MTG PLATE MTG 

HOLES 8X PLCS 

5/16 DIA. 

5

4

TEST 

BUTTON

Отзывы: