Problem

Cause(s)

Solution(s)

Grill plates not heated when power and 

thermostat indicator are both on.

1. 

Temperature control broken.

2.

 At least one heating element broken. 

3.

 Overheat thermostat is activated.

1.

 Replace temperature control.

2.

 Replace broken heating element.

3.

 Reset the overheat thermostat.

Temperature cannot be controlled when 

power is on, temperature controller is 

on and thermostat indicator on.

Temperature control is broken.

Replace temperature control.

Indicator not on when power on and 

heating process normal.

Indicator is broken.

Neon indicator may need replacing.

Power indicator not on when power on. 

1.

 Power cut or abnormal power supply. 

2.

 Fuse in plug has blown.

1.

Check plug and power supply.

2.

 Change fuse.

If a problem occurs that does not appear on this table, stop using the grill and seek help from the manufacturer, a qualified 

technician or an authorised dealer.

TROUBLE SHOOTING

If for any reason the unit over heats, a safety cut-out is automatically activated.
This can be reset manually by unscrewing the black cap on the back of the grill and pushing the reset button.

Contact a qualified technician or an authorised dealer if safety reset repeatedly needs resetting during normal use.

SAFETY RESET

Содержание RCG1

Страница 1: ...0 1293 652 555 Email info dualit com www dualit com C C C C Contact Information Contact Grills Please carefully read this manual before using this product Make sure you are familiar with all of the s...

Страница 2: ...roduct may be hot before and after it has been used RISK OF SEVERE BURNS DO NOT use the product during a thunderstorm To avoid it being damaged by a lightning strike unplug it removing it from electri...

Страница 3: ...l Complying fully with safety regulations connect the earth wire with suitable cable Thank you for purchasing this Dualit Contact Grill The Dualit range includes three sizes Single Contact Grill for i...

Страница 4: ...pply Store grill in a safe clean dry well ventilated place if it is not going to be used for any length of time Handle the grill with care when transporting DO NOT turn the grill upside down This will...

Страница 5: ...rocess normal Indicator is broken Neon indicator may need replacing Power indicator not on when power on 1 Power cut or abnormal power supply 2 Fuse in plug has blown 1 Check plug and power supply 2 C...

Страница 6: ...rill plate and ribbed upper grill plate Voltage 220 240V 50 60Hz 220 240V 50 60Hz 220 240V 50 60Hz Power 1 8KW 2 2KW 3 6KW Temperature range 50 300 C 50 300 C 50 300 C Upper grill plate size 214 x 214...

Страница 7: ...efore returning any product under this Guarantee please check that You have followed the product instructions correctly Your mains electricity supply is functional The defect is not due to a blown fus...

Страница 8: ...Issue 7 05 11 Dualit County Oak Way Crawley West Sussex RH11 7ST Telephone 44 0 1293 652 500 Fax 44 0 1293 652 555 Email info dualit com www dualit com...

Отзывы: