9.3
Mifare KEY type, Block number, ID position, Wiegand format option
set
Following is the communication frame for Mifare KEY type, Mifare block number, Mifare ID
position, Wiegand format option set. Since it is saved in flash memory after the first setting, the
reader does not need to be set again.
(115,200bps, 8 data, no parity, 1 stop bit)
STX
LENH
LENL
CMD
DATA
LRC
0x02
0x00
0x0B
0xE2
DATA[1] ~ DATA[10]
LENL ^ CMD ^ DATA[0]
( ^ : exclusive oring)
Cf. Wiegand 34Bit, 48Bit, 66Bit is following Wiegand Parity option of command 0xE0 bit2.
DATA[x]
State
Description
DATA[1]
Mifare KEY type
0: A KEY
1: B KEY
DATA[2]
Mifare Block Number
Mifare Block Number: 0 ~ 0xFF
DATA[3]
RFU
Recommend 0xFF
DATA[4]
RFU
Recommend 0xFF
DATA[5]
RFU
Recommend 0xFF
DATA[6]
RFU
Recommend 0xFF
DATA[7]
RFU
Recommend 0xFF
DATA[8]
RFU
Recommend 0xFF
DATA[9]
Mifare ID Position
ID Position: 0 ~ 0xFF
DATA[10]
Wiegand Length
Wiegand Data length: 0x04
Wiegand 32bit
0x07
Wiegand 56bit
Else anything: Wiegand 64bit