5. Installation
5.1 From the pump and gearbox (if fitted) remove the ‘Red’ travel plugs,
replacing them with the yellow-topped dipsticks. Check all oil levels, top
up if necessary.
5.2 Fill engine with oil and fuel, see engine manufacturers handbook
for details of oil and fuel types.
5.3 Connect the battery leads. (Electric start models only).
5.4 Connect the suction hose to the Power Washer (fig 3). Ensure the
connection has no air leaks. Air leaks on the suction hose connection
will impair the performance of the machine.
5.5 Connect the water return line to its connector and place the other end in
the water supply container. (Bypass to tank models only)
(Fig 2 item 16 & Fig 4).
5.6 Submerge the opposite end of the suction hose and its suction filter in a
suitable container containing the water supply (fig 4). Ensure the filter is
always kept below the water level.
5.7 Connect the high-pressure hose to the power washer (fig 5) and to the
lance (fig 6). Tighten as appropriate, do not over tighten.
Ensure that the trigger safety catch is in the
ON position
whilst making
these connections.
Fig 3. Connect the suction hose.
Fig 4. Submerge the suction hose.
Fig 5. Connect the High-Pressure Hose
to the Power Washer.
Fig 6. Connect the High-Pressure
Hose to the Lance.
NOTE
KEEP SUCTION FILTER CLEAN
Return
Suction
Return Hose
depending on
model