
30
14- ERROR MESSAGES
ERROR SHOWED ON DISPLAY
APPEARS WHEN
LED SENSOR ERROR
LED thermal sensor damaged (open or in
short circuit).
Unit immediately goes in black-out.
LED OVERTEMP
LED temperature detected over 100°C.
Unit immediately goes in black-out.
DRV1 MICRO SENSOR ERROR
Micro controller thermal sensor on LED
Driver Master board damaged (open or in
short circuit).
Unit immediately goes in black-out.
DRV1 MICRO OVERTEMP
Temperature of Micro controller on LED
Driver Master board detected over 100°C.
Unit immediately goes in black-out.
DRV2 MICRO SENSOR ERROR
Micro controller thermal sensor on LED
Driver Slave board damaged (open or in
short circuit).
Unit immediately goes in black-out.
DRV2 MICRO OVERTEMP
Temperature of Micro controller on LED
Driver Slave board detected over 100°C.
Unit immediately goes in black-out.
DRV1 NTC1 SENSOR ERROR
Thermal sensor on outputs 6 and 7 of LED
Driver Master board damaged (open or in
short circuit).
Unit immediately goes in black-out.
DRV1 NTC1 OVERTEMP
Temperature detected over 100°C on
outputs 6 and 7 of LED Driver Master
board. Unit immediately goes in black-out.
DRV1 NTC3 SENSOR ERROR
Thermal sensor on outputs 2 and 3 of LED
Driver Master board damaged (open or in
short circuit).
Unit immediately goes in black-out.
DRV1 NTC3 OVERTEMP
Temperature detected over 100°C on
outputs 2 and 3 of LED Driver Master
board. Unit immediately goes in black-out.
DRV2 NTC1 SENSOR ERROR
Thermal sensor on outputs 6 and 7 of LED
Driver Slave board damaged (open or in
short circuit).
Unit immediately goes in black-out.
DRV2 NTC1 OVERTEMP
Temperature detected over 100°C on
outputs 6 and 7 of LED Driver Slave
board. Unit immediately goes in black-out.
DRV2 NTC3 SENSOR ERROR
Thermal sensor on outputs 2 and 3 of LED
Driver Slave board damaged (open or in
short circuit).
Unit immediately goes in black-out.
DRV2 NTC3 OVERTEMP
Temperature detected over 100°C on
outputs 2 and 3 of LED Driver Slave
board. Unit immediately goes in black-out.
Содержание X-BRICK
Страница 1: ...X BRICK USER S MANUAL rel 1 0 GB ...
Страница 35: ...35 20 LED PIXEL INVERT FUNCTION REFERENCES ...
Страница 58: ...58 NOTES ...
Страница 59: ...59 NOTES ...