DTS SLICE Distributor Скачать руководство пользователя страница 4

SLICE Distributor 

User’s Manual 

February 2018 

 
 

 
 

support.dtsweb.com

 

4

 

13000-30030-MAN (Rev. 3)

 

Introducing the SLICE Distributor 

The  SLICE  Distributor  serves  as  a  single  interface  supporting  power,  Ethernet 
communications and status signals for an extended SLICE system.  It supports in excess of 
200  channels  via  4  SLICE  MICRO/NANO  chains  (4  stacks per  chain),  and  is designed  to 
integrate in-dummy and withstand high shock environments. 

  Rated for 500 g dynamic testing environments. 

  Supports >200 SLICE MICRO/NANO DAS channels via 4 SLICE system connectors. 

  Supports an input range of 9-18 VDC (15 VDC nominal), 10 A maximum. 

  Supports main and battery back-up power inputs. 

  Supports Ethernet communications. 

  Over-  and  undervoltage  protection,  overcurrent  protection,  power  input  polarity 

protection. 

  LED indicator provides status information. 

  Integral mounting holes. 

  Ideal for embedded and in-dummy high channel-count applications. 

SLICE Distributor Connector Panel 

The  ON  switch,  LED  indicator  and  all  connectors  are  accessible  from  the  front  panel.  
Instructions  on  how  to  properly  connect  cables  can  be  found  in  the  section  on 
Troubleshooting  Basics.    Connector  information  and  pin  assignments  can  be  found  in 
Appendix A.  Mechanical specifications are included in Appendix B.   Appendix C provides 
information on the network parameters of your equipment. 

 
 

 

 

 

 
 
 

 

SLICE Distributor Connector Panel 

SLICE MICRO/NANO DAS connectors (1-4) 

  - Functionally identical 
  - Supports power, start, event, status and 
    USB communications 

Status LED

 

Pushbutton 

Switch

 

SYS connector 

  - Main power input 
  - Ethernet communications 
  - Status and control signals 

AUX connector 

  - Status and control signals 
  - Back-up power input 

Содержание SLICE Distributor

Страница 1: ...13000 30030 MAN Rev 3 Diversified Technical Systems Inc All Rights Reserved SLICE Distributor User s Manual February 2018...

Страница 2: ...6 SLICE System Connectors 6 Basic Care and Handling 7 Shock Rating 7 Mounting Considerations 7 Thermal Considerations 7 Power Management 8 Maximum Power Consumption 8 Maximum Input Power 8 Maximum Out...

Страница 3: ...rience to help via telephone e mail or on site visits The best way to contact a DTS support engineer is to submit a request through the DTS Help Center web portal support dtsweb com You must be regist...

Страница 4: ...vercurrent protection power input polarity protection LED indicator provides status information Integral mounting holes Ideal for embedded and in dummy high channel count applications SLICEDistributor...

Страница 5: ...s overvoltage or overcurrent condition is present If unit is on cycle power to reset On Off Pushbutton Switch A momentary pushbutton switch is used for on off control When the unit is on LED is blue a...

Страница 6: ...for the DAS One SLICE connector supports up to 3 SLICE stacks with a maximum of 8 SLICE Bridges per stack in any combination of SLICE MICRO or NANO SLICE MICRO Accel and ARS units can be used in plac...

Страница 7: ...r repair Shock Rating The SLICE Distributor is rated for 500 g 4 ms half sine duration in all axes Mounting Considerations The unit should be securely bolted to the test article or dynamic testing dev...

Страница 8: ...utput power available per SLICE system connector is 12 V at 4 A The maximum output current available via the AUX connector is 2 5 A input VDC output VDC Charging Powering Attached Equipment When suffi...

Страница 9: ...est fixture to confirm resistance readings of 1 ohm TroubleshootingBasics Begin troubleshooting by checking the operational state of the SLICE Distributor alone DTS suggests always using the connectio...

Страница 10: ...lth If the status LED is red this can mean input voltage is too high or overcurrent condition is present You will need to correct this before proceeding 4 Connect the Ethernet comm cable from the SYS...

Страница 11: ...to pin 2 3 Event isolated bi directional contact closure to pin 2 4 Recording status high recording 4 Recording status high recording 5 Reserved 5 ON status 6 VDC input from ext battery Ground 6 Groun...

Страница 12: ...into the connector Pin Function 1 ON bi directional contact closure input to ground 2 START bi directional contact closure input to ground 3 EVENT bi directional contact closure input to ground 4 Stat...

Страница 13: ...Cable SLICE Distributor to DDX cable SDX 1 m 13000 30440 SLICE Distributor AUX Connector Assy 13000 30441 SLICE Distributor AUX Cable Assy 5 m pigtail term 13000 30450 SLICE Distributor SYS Connector...

Страница 14: ...0 SD00200 SD00300 x 101 for S Ns SD00101 SD00201 SD00301 x 2 99 for S Ns SD00102 SD00399 Netmask 255 255 252 0 The calibration data for your equipment identifies the IP address as shipped from the fac...

Страница 15: ...urrent IP address Use compatibility mode with Internet Explorer Enter the desired IP address and or netmask into the available fields and click Apply If the IP address is valid the page will show succ...

Страница 16: ...number of stacks was 4 now 3 referenced in second paragraph and illustrations on page 6 Updated network info to refer to Appendix C Rev 3 27 Feb 2017 EK Added Appendix C and page 8 footnote Updated a...

Отзывы: