
24
15- ERROR MESSAGES
ERROR SHOWED ON DISPLAY
APPEARS WHEN
LED thermal sensor damaged (open or in
short circuit).
Unit immediately goes in black-out.
LED temperature detected over 70°C.
Unit immediately goes in black-out.
Micro controller thermal sensor damaged
(open or in short circuit).
Unit immediately goes in black-out.
Micro controller temperature detected over
70°C. Unit immediately goes in black-out.
Thermal sensor on outputs 1 and 2 of LED
Driver board damaged (open or in short
circuit).
Unit immediately goes in black-out.
Temperature detected over 70°C on
outputs 1 and 2 of LED Driver board. Unit
immediately goes in black-out.
Thermal sensor on outputs 3 and 4 of LED
Driver board damaged (open or in short
circuit).
Unit immediately goes in black-out.
Temperature detected over 70°C on
outputs 3 and 4 of LED Driver board. Unit
immediately goes in black-out.
Содержание SCENA LED 120 HQS
Страница 1: ...SCENA LED 120 HQS USER S MANUAL rel 1 0 GB...