5.2- Movement
The projector has a maximum vertical movement of +/- 45°
5.3- Risk of fire
Each fixture produces heat and must be installed in a well-ventilated place. The minimum recommended
distance from flammable material is 1 MT.
Minimum distance from the object being illuminated is 2 MT.
5.4- Forced ventilation
You will note, on inspection, that the PHARUS features various air inlets and cooling fans located on both
ballast and projector. These should, under no circumstances, be blocked or obstructed whilst the
projector is in operation.
Doing so could cause the fixture to seriously overheat thereby compromising its proper operation.
5.5- Ambient temperature
The projector should never be installed in places that lack a constant air flow. The ambient temperature
should NOT exceed 40°C.
6- MAINS CONNECTION
PHARUS with electronic ballast operate at 90-260 VOLT 50-60 Hz.
PHARUS with electromagnetic ballast operate at 220-240 VOLT 50-60 Hz
Prior to connecting the unit to your mains supply,
ensure that the model in your possession correctly matches
the mains supply available. For connection purposes,
ensure that your plug is capable of supporting 8 amps at 220-240V,
Or 16 amps at 110 V
Strict adherence to regulatory norms is strongly recommended.
or 110 V 50-60 HZ.
+45°
Electromagnetic ballast
220-240 V 50/60 Hz
o
r 110 V 50-60 Hz
-45°
PHARUS
Knobs for vertical
position adjustment
10
6.1- Protection
The use of a thermal magnetic circuit breaker
is recommended for each PHARUS.
A good earth connection is essential
for the correct operation of the projector.
Electronic ballast
90-260V 50 / 60Hz