background image

ARC 1200

5

NICK WASH 600

4- TECHNICAL FEATURES

The 

 FAR features also a Free Axis Rotation (“FAR”) system. 

The FAR allows limitless pan and tilt rotation: the NICK head rotates freely on its axes, horizontally or 
vertically, without interruption, in either direction, never having to reverse motion.

NICK WASH 600

03.LDR005.T
03.LDR005.TF
03.LDR005.TWS

5- TECHNICAL SPECIFICATIONS

Overview

NICK WASH 600 is a self-contained compact high-output LED moving head projector with 13,5° - 40° 
motorized zoom.
NICK WASH 600 is one of the brightest compact LED projectors on the market: luminosity at 5 m is no 
less than 3.100 Lux (13,5°).

Applications

NICK WASH 600 is ideal in various applications, such as: lighting shopping malls, libraries, museums, 
exhibitions, clubs, restaurants, buildings, monuments, as well as special events, fashion displays, etc. 
The unit is easily installable even in the most refined settings, thanks to its attractive appearance.

LED technology

NICK WASH 600 light source is composed of 120 LEDs (30 Red,30 Green, 30 Blue, 30 White) with 9.750 
total lumens.
The LEDs even distribution pattern featuring the same quantity of red, green, blue and white LEDs 
guarantees high colour mixing quality and a uniform projection on surfaces, no matter what colour
is used.
NICK WASH 600 offers 2 different colour mixing modes (RGBW / CMY) and can generate 16 million 
colours; colour temperature can be varied over a linear range from 2800°K to 6500°K.
Also, users can memorize a personalized white either from the menu or via DMX. The white is recalled 
with the dedicated DMX “White” channel. 
NICK WASH 600 is also available with 90 White +30 Amber LEDs, or in an RGBA version (on request).

Zoom 

Pan/Tilt 

Full-range power supply

NICK WASH 600 features a motorized linear Zoom (13,5°- 40°) with a high efficiency optics system; 
zoom movement is smooth and uniform.
NICK WASH 600 features a motorized movement on horizontal (540° pan) and vertical (270° tilt) axes; 
the unit can operate in vertical, horizontal or inverted positions, and can be positioned on the floor or 
ground, or fitted to trusses; it is complete with a practical accessory for anchorage to the ground.

NICK WASH 600

NICK WASH 600 has a full-range AC 90-260 V, 50-60 Hz power supply, therefore ensures reliable 
operation even in the case ofvoltage drops. Also, the unit can be used all over the world with no
specific adaptations, as the right voltage is always supplied.

 Electr. Power Supply, Motorized Zoom, Black colour

 Electr. Power Supply, Motorized Zoom, F.A.R. system, Black colour

 Electr. Power Supply, Motorized Zoom, Wireless DMX ready, Black colour

LED technology

120 LEDs (30 Red, 30 Green, 30 Blue, 30 White); total luminous flux 9.750 Lumens
RGBW colour generation (16 million colours); 3 different colour mixing modes: RGBW, CMY, HSV
Colour temperature variable on a linear range (2.800°K÷6.500°K); no infrared / no ultraviolet emissions
LEDs average lifespan: 100.000 hours

Zoom 

Motorized Zoom 13,5°- 40°

User interface

OLED colour d 4 buttons

Содержание Nick Wash 600

Страница 1: ...Italy D T S Illuminazione srl Via Fagnano Selve 10 12 14 47843 Misano Adriatico RN ITALIA Tel 39 0541 611131 Fax 39 0541 611111 info dts lighting it http www dts lighting it GB GB User s Manual Rel 1 2 User s Manual Rel 1 2 ...

Страница 2: ...rcuits described herein Les informations contenues dans le présent manuel ont été rédigées et contrôlées avec le plus grand soin Nous déclinons toutefois toute responsabilité en cas d éventuelles inexactitudes Tous droits réservés Ce document ne peut être copié photocopié ou reproduit dans sa totalité ou partiellement sans le consentement préalable de se réserve le droit d apporter toutes modifica...

Страница 3: ...el of protection against the penetration of solid and liquid objects 8 VOLTAGE AND FREQUENCY 9 9 INSTALLATION 9 9 1 Safety cable 9 2 Protection against liquids 9 3 Movement 9 4 Risk of fire 9 5 Forced ventilation 9 6 Ambient temperature 10 MAINS CONNECTION 10 10 1 Protection 11 DMX SIGNAL CONNECTION 11 11 1 DMX Addresses 11 2 Selecting the DMX address 12 FIRMWARE UPDATING 12 13 DISPLAY FUNCTIONS 1...

Страница 4: ...he lamp The lamp must be replaced if it has been damaged or deformed by prolonged use or overheating The device must always be equipped with an efficient ground connection 3 GENERAL WARRANTY CONDITIONS The unit is guaranteed for 24 months from the date of purchase against manufacturing material defects THIS SYMBOL INDICATES A HOT SURFACE THIS SYMBOL INDICATES ELECTRIC SHOCK RISK THIS SYMBOL INDICA...

Страница 5: ...e varied over a linear range from 2800 K to 6500 K Also users can memorize a personalized white either from the menu or via DMX The white is recalled with the dedicated DMX White channel NICK WASH 600 is also available with 90 White 30 Amber LEDs or in an RGBA version on request Zoom Pan Tilt Full range power supply NICK WASH 600 features a motorized linear Zoom 13 5 40 with a high efficiency opti...

Страница 6: ...ection rate Movements horizontal pan vertical tilt axes Motorized movement 540 Pan 2 0 sec 270 Tilt 1 2 sec Power supply consumption Full range AC 90 260V 50 60Hz Power consumption 90 V 2 65 A 240 W 120 V 2 A 240 W 230 V 1 A 240 W 260 V 0 9 A 240 W Thermal Operating ambient temperature 10 40 Finishes Black or white finish Certification and Safety Certification CE LED Class Class 2 LED product Weig...

Страница 7: ...olour Electr Power Supply Motorized Zoom F A R system Black colour Nick Wash 600 Electr Power Supply Motorized Zoom Wireless DMX ready Black colour Flight cases Professional Flight case for 4 units compartment for accessories swivel wheels cover with hinges with stay dishes on cover for piling 8 handles 2 eachside cod 0521C046 1 Wireless DMX receivers retrofits for Wireless DMX Receiver Card with ...

Страница 8: ...nection is essential for proper functioning of the projector Never connect the unit without proper earth connection The fixture should be located in places with a good air ventilation 7 3 Safety The projector should always be installed with bolts clamps and other tools that are capable of supporting the weight of the unit Always use a second safety cable to sustain the weight of the unit in case o...

Страница 9: ...s connections placed in the base of the units allow to hang the NICK WASH 600 by using the Fast Lock C clamps provided in the box 9 1 Safety cable We recommend the use of a safety chain cord connected to the NICK WASH 600 and to the suspension truss in order to avoid the fixture accidentally falling should the main fixing point fail Make sure that the iron cable or chain can bear the weight of the...

Страница 10: ...eration 9 6 Ambient temperature The projector should never be installed in places that lack a constant air flow The ambient temperature should NOT exceed 40 C 10 MAINS CONNECTION NICK WASH 600 operate at 90 260 VOLT 50 60 Hz Prior to connecting the unit to your mains supply ensure that the model in your possession correctly matches the mains supply available For connection purposes ensure that you...

Страница 11: ... projectors are cascade connected NB If the display showing the DMX address flashes then one of the following errors has occurred DMX signal not present DMX address not valid DMX reception problem For Installations where long distance DMX cable connections are needed we suggest to use a DMX terminator The DMX terminator is a male XLR 3 5 pins connector with a 120 ohm resistor Between pin 2 and 3 T...

Страница 12: ... projector 6 A086 20 channels mode default for FAR model Projector 1 A001 Projector 2 A021 If you want to select the next projector just add 20 Projector 3 A041 A projector 6 A101 Please refer to an authorised D T S service centre D T S Firmware upgrade utility program D T S Firmware upgrade utility 12 FIRMWARE UPDATING Warning This procedure require a base knolewge of computer applications and Wi...

Страница 13: ...ND Default SUSPENDED ENTER Menu DISPLAY POSITION STAND BY Display Position Reverses display s reading depending on the mounting position On the ground or suspended Display Standby To turn off the display after 5 seconds Or leave it always on Display Standby OFF Display Standby disabled Default ON Display goes OFF after 5 seconds ENTER MENU ENTER DOWN UP AA DISPLAY MENU ENTER DOWN UP OFF DISPLAY PO...

Страница 14: ... settings have priority on Master Dimmer DMX channel 7 SMOOTH VALUE This menu allow to select the value of the delay in millisecons for RGBA and Dimmer channels reaction to DMX or Program variation 4 25 ms delay Fast response 20 250 ms delay Slow response GAMMA CORRECTION This menu allow to select between Linear current output or Quadratic current output for LEDs Default Linear OUTPUT FREQUENCY Th...

Страница 15: ...D s current from 350mA to 500 mA AUTO Up Down Up Down ENTER Menu MENU ENTER DOWN UP 20 ch DMX SET DMX MODE MENU ENTER DOWN UP AUTO NICK WASH 600 SURE Menu NO Enter YES ENTER AUTOMATIC MODE Automatic demo game without DMX controller PERSONAL COLOURS RGBA Dimmer Shutter Pan Tilt and Zoom values selectable by user FIXED COLOURS Sixteen Colour Macros as on MACRO channel Dimmer Shutter Pan Tilt and Zoo...

Страница 16: ...R unit set in AUTO MODE in order to ran the units in SLAVE mode By setting all the SLAVE units connected to the MASTER to DMX address 1 them will be sinchronized with the Master unit following the chase selected on it but running their own Pan Tilt and Zoom position The SLAVE unit receive DMX signal from the MASTER unit By setting all the SLAVE units connected to the MASTER to DMX address 1 them w...

Страница 17: ... mode and continue transmitting data The NICK WASH 600 now try to synchronize to the transmitter When synchronized to the transmitter 2 different modes are possible 1 Antenna transmitter has detected and transmits a DMX signal in this mode a solid green light is seen on the transmitter and solid display is seen on NICK WASH 600 2 No DMX signal connected the Antenna transmitter will flash red green...

Страница 18: ... then ran if DMX signal is missing or not available Usefull for Emergency EXIT ilumination on public areas Dimmer leveL Pan Tilt and Zoom values selectable by user WHITE 1 16 Default WHITE 1 DIMMER Default 255 ENTER 13 DISPLAY FUNCTIONS ARC 1200 18 NICK WASH 600 MENU ENTER DOWN UP 20 ch DMX SET DMX MODE MENU ENTER DOWN UP 128 EMERGENCY PAN MENU ENTER DOWN UP 20 ch DMX SET DMX MODE MENU ENTER DOWN ...

Страница 19: ...wn ENTER Menu TEMPERATURE Unit temperature MENU ENTER DOWN UP 20 ch DMX SET DMX MODE MENU ENTER DOWN UP 13 Hr 08 min TIME TIME Up Down ENTER Menu LIFE TIME This menu show the total UNIT life time and the RGBA life time UNIT Up Down ENTER MENU ENTER DOWN UP 20 ch DMX SET DMX MODE MENU ENTER DOWN UP 0 Hr 08 min TIME RED MENU ENTER DOWN UP 20 ch DMX SET DMX MODE MENU ENTER DOWN UP 0 Hr 08 min TIME GR...

Страница 20: ...DE MENU ENTER DOWN UP SYTEM MOTORS FW UPGRADE PAN INVERSION This menu allows to set the Pan movement Normal or Reversed TILT INVERTION This menu allows to set the Pan movement Normal or Reversed PAN TILT SPEED Pan Tilt Speed control 1 4 PAN INVERTION Default NORM TILT INVERTION Default NORM PAN TILT SPEED CONTROL Default 4 FAN MAX SPEED This menu allow to select the internal fans speed FAN MAX SPE...

Страница 21: ...ware Pan Tilt Zoom Up Down ENTER MENU ENTER DOWN UP 20 ch DMX SET DMX MODE MENU ENTER DOWN UP Id 0D0E001D v1 19 Mar 30 2011 SOFTWARE LED LEDs CIRCUIT BOARD SOFTWARE MOTORS CIRCUIT BOARDS SOFTWARE PAN TILT ZOOM MENU ENTER DOWN UP 20 ch DMX SET DMX MODE MENU ENTER DOWN UP Pan Tilt v 1 7 Zoom v 1 8 SOFTWARE Motors NICK WASH 600 ...

Страница 22: ...ins power prior to removing the projector housing Fuse replacement Locate the fuse which protect the electronics in the base of the NICK WASH 600 Using a multimeter test the condition of the fuse replacing it with one of equivalent type if necessary Attention Disconnect mains power prior to removing the projector housing Fans and air passages The fans and air passages must be cleaned approximately...

Страница 23: ...T DMX CHANNEL 1 Parameter PAN msb DMX CHANNEL 2 Parameter PAN lsb DMX CHANNEL 3 Parameter TILT msb DMX CHANNEL 4 Parameter TILT lsb DMX CHANNEL 5 Parameter SPEED MOVEMENT DMX range Value Mid point DMX value Move range degrees Mode Option Function 0 10 Standard 11 25 Fast movement 26 127 Vector mode from fast to slow 128 247 Variable time reaction to DMX signal fast to slow 248 255 Slow reaction ti...

Страница 24: ...Move DMX range Mode Option Function range Value DMX value degrees 0 7 Black out 8 255 Proportional dimmer Proportional colour 0 255 degrees Value DMX value range Option DMX range Mid point Mode Function Move DMX CHANNEL 9 Parameter GREEN Proportional colour 0 255 degrees Value DMX value range Option DMX range Mid point Mode Function Move DMX CHANNEL 8 Parameter RED Proportional colour 0 255 degree...

Страница 25: ... value range degrees 0 55 23 No Function 56 105 80 Full Red Green Blue at Full 106 155 130 White DTS DMX CHANNEL 13 Parameter CTC Color temperature correction Move DMX range Mid point Mode Option Function Value DMX value range degrees 0 255 IF CHANNEL 12 WHITE PREPROGRAMMED WHITE CTC Dmx range value 206 255 Linear control temperature correction 0 2800 K 255 6800 K 156 205 180 Custom White Create R...

Страница 26: ...5 240 255 Macro 16 MENU Up Down Up Down ENTER ENTER IF DMX CHANNEL 14 Parameter COLOUR MACROS 135 144 145 154 155 164 165 174 DMX range 75 84 85 94 95 104 105 114 115 124 125 134 15 24 25 34 35 44 45 54 55 64 65 74 Value 0 14 DMX value Mid point degrees Move range Mode Option Macro 13 Macro 14 Macro 15 Macro 16 No Function Macro 1 Macro 2 Macro 3 Macro 4 Macro 5 Macro 6 Macro 7 Macro 8 Macro 9 Mac...

Страница 27: ...ove DMX range Mid point Mode Option Function Value DMX value range degrees 0 79 Custom White Recall 80 160 Custom White Create Enable CH 18 19 20 for Custom white Creation 161 255 Custom White Store Store the Custom White created DMX CHANNEL 16 ZOOM Parameter Move DMX range Mid point range Option Mode Function Value DMX value degrees Linear ZOOM from Narrow to Wide 13 5 40 0 255 IF CHANNEL 12 WHIT...

Страница 28: ...OOM 19 NO FUNCTION 16 DMX PROTOCOL NICK WASH 600 DMX CHANNEL 1 Parameter PAN msb DMX CHANNEL 2 Parameter PAN lsb DMX CHANNEL 3 Parameter TILT msb DMX CHANNEL 4 Parameter TILT lsb DMX CHANNEL 5 Parameter SPEED MOVEMENT DMX range Value Mid point DMX value Move range degrees Mode Option Function 0 10 Standard 11 25 Fast movement 26 127 Vector mode from fast to slow 128 247 Variable time reaction to D...

Страница 29: ... spin rotation speed from min to max 021 030 Position mode 720 2 turns 081 090 Position mode 1080 3 turns 051 060 DMX CHANNEL 7 Parameter TILT FAR DMX range Value Mid point DMX value Move range degrees Mode Option Function 000 010 Position mode 270 standard path 011 020 Position mode 360 1 turn 031 040 Position mode 1440 4 turns 041 050 Position mode 1800 5 turns 061 070 Position mode 2160 6 turns...

Страница 30: ...e Mode Option Function range Value DMX value degrees 0 7 Black out 8 255 Proportional dimmer Proportional colour 0 255 degrees Value DMX value range Option DMX range Mid point Mode Function Move DMX CHANNEL 11 Parameter GREEN Proportional colour 0 255 degrees Value DMX value range Option DMX range Mid point Mode Function Move DMX CHANNEL 10 Parameter RED Proportional colour 0 255 degrees Value DMX...

Страница 31: ... degrees 0 55 23 No Function 56 105 80 Full Red Green Blue at Full 106 155 130 White DTS DMX CHANNEL 15 Parameter CTC Color temperature correction Move DMX range Mid point Mode Option Function Value DMX value range degrees 0 255 IF CHANNEL 14 WHITE PREPROGRAMMED WHITE CTC Dmx range value 206 255 Linear control temperature correction 0 2800 K 255 6800 K 156 205 180 Custom White Create RGB levels se...

Страница 32: ...ro Macro Macro Macro 13 Macro 14 Macro 15 240 255 Macro 16 MENU Up Down Up Down ENTER ENTER IF DMX CHANNEL 16 Parameter COLOUR MACROS 135 144 145 154 155 164 165 174 DMX range 75 84 85 94 95 104 105 114 115 124 125 134 15 24 25 34 35 44 45 54 55 64 65 74 Value 0 14 DMX value Mid point degrees Move range Mode Option Macro 13 Macro 14 Macro 15 Macro 16 No Function Macro 1 Macro 2 Macro 3 Macro 4 Mac...

Страница 33: ...n Value DMX value range degrees 0 79 Custom White Recall 80 160 Custom White Create Enable Custom white Creation 161 255 Custom White Store Store the Custom White created DMX CHANNEL 18 ZOOM Parameter Move DMX range Mid point range Option Mode Function Value DMX value degrees Linear ZOOM from Narrow to Wide 13 5 40 0 255 IF CHANNEL 14 WHITE PREPROGRAMMED Dmx range value 156 205 MENU ENTER IF DMX S...

Страница 34: ...ARC 1200 34 NOTES NICK WASH 600 ...

Страница 35: ...ARC 1200 35 NOTES NICK WASH 600 ...

Страница 36: ...prior written consent from D T S D T S reserves the right to make any aesthetic functional or design modifications to any of its products without prior notice D T S assumes no responsibility for the use or application of the products or circuits described herein MADE IN ITALY D T S Illuminazione s r l Via Fagnano Selve 10 12 14 47843 Misano Adriatico RN Italy Tel 39 0541 611131 Fax 39 0541 611111 ...

Отзывы: