For Your Safety 

In order to ensure the proper and safety use of NETIMPRESS avant, please be sure to follow the 

safety precaution mentioned below as operating NETIMPRESS avant. DTS INSIGHT 

CORPORATION has no responsibility or guarantee for any injuries which occur as a result of the 

violation of these safety caution and warnings. 
 

This manual uses the icons as below to use NETIMPRESS avant safety. 

         

 

It indicates not only that there is a danger to human as well as to the 

equipment, but also that it is necessary to refer to the instruction manual.  
 

 

It indicates a safety ground terminal. As this terminal is on the main unit, 

please be sure to connect this terminal to the ground before operating.   
 

Warning

 

In order to avoid the risk of death or serious injury which may occur as a result 

of an incorrect use. 

Note

 

In order to avoid the risk of minor or material damage which may occur as a 

result of an incorrect use.  
 

 
 

To avoid the risk of death or serious injury to users, such as electrocution or 

any other accidents, as well as the risk of damage to NETIMPRESS avant, 

please follow the warnings mentioned below.

 

  Warning   

Use in Chemical Gases 

Do not use NETIMPRESS avant in an environment where are combustible or explosive gases or 

steam. 
Using NETIMPRESS avant in such environment is extremely dangerous. 

 

Usage environment

 

This programmer is only for indoor use. Use it at an altitude of 2000 meters or less.

   

Available voltage range and power-supply frequency must not exceed the rated voltage ± 10%, 
50/60 Hz±2 Hz.

 

We are assuming NETIMPRESS avant will be used under Overvoltage category II and Pollution Degree 
2.

 

Install it around an electric outlet so that you can unplug it to shut down the power easily. 

 

 

Содержание NETIMPRESS avant

Страница 1: ...Flash Programmer Hardware Manual DTS INSIGHT CORPORATION...

Страница 2: ...r by any means electronic or mechanical without the written permission of DTS INSIGHT CORPORATION 2 The contents of this manual are subject to change without prior notice due to improvement of the fun...

Страница 3: ...avant Please read the manual along with this manual The wording Programming in this manual means writing data into a target microcomputer flash memory or an external flash memory connected to the tar...

Страница 4: ...injury which may occur as a result of an incorrect use Note In order to avoid the risk of minor or material damage which may occur as a result of an incorrect use To avoid the risk of death or seriou...

Страница 5: ...eration Do not use damaged AC cable Do not remove the case Only qualified service engineers should remove the case of NETIMPRESS avant because of the high voltage Action to be taken if abnormality is...

Страница 6: ...r Connecting the Probe and Connector All probes and cables are designed to prevent an incorrect connection Never force them to plug in nor unplug Confirm the position and direction Insertion and remov...

Страница 7: ...dustrial environment only WEEE marking WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT DIRECTIVE 2012 19 EU Waste Electrical and Electronic Equipment Directive WEEE is for EU countries NETIMPRESS avant comp...

Страница 8: ...guarantees only if there are any damages of media provided by DTS INSIGHT Corporation or manual defects If proved that there are failures or that there are problems apart from those listed above the a...

Страница 9: ...or each definition program This definition license file LCT file can be downloaded if you register your information in our website by referring to the definition license sheet provided when you purcha...

Страница 10: ...2 GENERAL PRECAUTIONS 12 3 NAME AND FUNCTION OF THE COMPONENTS 13 3 1 Name of Components 13 3 2 Function of Components 14 4 SPECIFICATIONS 15 4 1 General Specification 15 4 2 Interface 15 4 3 Complia...

Страница 11: ...oration AC cable for power on or SD card are not included in the main unit Please purchase them with the main unit Remote controller for NETIMPRESS avant PC software SWX600 can be downloaded from our...

Страница 12: ...in the SD card Therefore you can use it as a stand alone without PC 1 2 Communication Environments Standard Ethernet TCP IP can be used for communication between NETIMPRESS avant and a host PC Theref...

Страница 13: ...n turn on the power of NETIMPRESS avant first and then a user system To turn off the power follow the reverse order 6 NETIMPRESS avant operates with the control module set into the SD card connector N...

Страница 14: ...a bar code reader DIO Connector This is the connector to control by Digital I O SD CARD Slot Slot for inserting the SD card POWER SW Power switch for turning on off the power source AC Inlet Connecto...

Страница 15: ...SET button is used when you want to set and execute the settings MENU MENU button is used when you want to display the menu window EXT1 EXT2 EXT1 EXT2 buttons are used to read corresponding execution...

Страница 16: ...ply Input voltage range AC 100 to 240 V 50 to 60 Hz Consumed power Less than 12W 0 25A External dimensions 160 L x 110 W x 55 H mm Weight 750 g Installation Lay down horizontally Do not stack Calendar...

Страница 17: ...ctor pin arrangement mate side view Signal Table Table 1 AFX100 Probe Connector Signal List pin No Signal Name definition I O 1 TX1 Send data 1 Output O 2 TX1 Send data 1 Output O 3 RX1 Received data...

Страница 18: ...pose output port 5 Digital input Number of script selection port 8 select from 255 types Number of general purpose port 5 Number of control port 4 STEP START EXT1 EXT2 Clear signal 1 CLR Power input P...

Страница 19: ...signal 2 Digital I O input I B 11 Digital I O ST3 Script selection signal 3 Digital I O input I B 12 Digital I O ST4 Script selection signal 4 Digital I O input I B 7 Digital I O ST5 Script selection...

Страница 20: ...elay Type B 5 6K Load Pass Error Run Digital I O OUT Connection of output signal Use it by connecting to devices controlled by current drive such as relay control or LED You can also use it by connect...

Страница 21: ...Specifications EXT1 EXT2 Digital I O INx Digital I O STx STEP START 1 Changeable by a filter setting Key entry 1 Key entry 2 30 ms 30 ms Minimum 200 ms Max DIL D 1 to 256 ms 1 1 to 256 ms 1 Minimum M...

Страница 22: ...l I O output Type B Item Specifications Input format DC voltage Plus common Common 16 points common Insulation Photocoupler insulation Rated input voltage 12 24V DC Range of usable voltage 10 2 to 26...

Страница 23: ...nnector type Pin assignment Pin No Signal Name Definition I O 1 VCC Output 5 V Max 500mA for 1 and 6 pin together OUT 2 GND GND 3 RSV 4 RSV OUT 5 RXD Receive input for communication IN 6 VCC Output 5...

Страница 24: ...ns Safety standard Compliant standards EN61010 1 Emission Compliant standards EN61326 1 class A KN11 KN 61000 6 2 Immunity Compliant standards EN61326 1 Table2 For use in industrial locations RoHS Com...

Страница 25: ...y with factory setting Please make sure to add a license before operation For how to add a license see the NETIMPRESS avant startup Manual For microcomputer which is same series as the MCU supported b...

Страница 26: ...25 5 1 SD card for NETIMPRESS avant 5 1 1 AFM700 AFM700 4G Dedicated SD card 4GB AFM700 32G Dedicated SD card 32GB...

Страница 27: ...2 PROBE HARD 5 2 1 PHX400 Dimensional drawing Below shows surface and pins configuration 95 L 65 W 25 H mm 13 1 25 14 RDBD 25SE1 M2 6 55 Hirose Electric Co LTD MC08P2LPG30XSB2 Cable Force 95 25 65 200...

Страница 28: ...ies according to definition program I O A IO8 TAUX4 I O terminal definition varies according to definition program I O B IO9 TMODE I O terminal definition varies according to definition program I O B...

Страница 29: ...m I O A IO7 TAUX3 I O terminal definition varies according to definition program I O A IO8 TAUX4 I O terminal definition varies according to definition program I O B IO9 TMODE I O terminal definition...

Страница 30: ...utput in dual or quad modes I O IO6 CS chip select output of negative logic O A IO7 TAUX3 I O terminal definition varies according to definition program I O A IO8 TAUX4 I O terminal definition varies...

Страница 31: ...definition varies according to definition program I O A IO7 TAUX3 I O terminal definition varies according to definition program I O A IO8 TAUX4 I O terminal definition varies according to definition...

Страница 32: ...IO6 TAUX2 I O terminal definition varies according to definition program I O A IO7 TAUX3 I O terminal definition varies according to definition program I O A IO8 TAUX4 I O terminal definition varies...

Страница 33: ...32 Interface circuit specification Type A Type B Type C 1M XV 7SZ125 68 47 LVC244 3 3V Internal power...

Страница 34: ...33 Type D Type E To XV 1M 220 TRES WDT NETIMPRESS side User Target side XV To Output Buffer VCC...

Страница 35: ...34 Type F...

Страница 36: ...TMS A yellow 17 GND yellow black 5 I O TAUX nTRST A brown 18 GND brown black 6 I O TAUX2 A blue 19 GND blue black 7 I O TAUX3 A orange 20 GND orange black 8 I O TAUX4 B grey 21 I O TMODE B grey black...

Страница 37: ...absolute rating 7 0 V Output voltage VoL Isink 3mA 0 7 V IO1 IO7 Output voltage VoH IoH 100uA XV 2 3V 2 2 V XV 3 0V 2 9 XV 4 5V 4 4 VoL IoH 100uA XV 2 3V 0 1 XV 3 0V 0 1 XV 4 5V 0 1 Output current Io...

Страница 38: ...37 5 2 2 PHX401 Dimensional drawing Below shows surface and pins configuration 95 L 65 W 25 H mm 65 2000 300 13 1 25 14 RDBD 25SE1 M2 6 55 Hirose Electric Co LTD MC08P2LPG30XSB2 Cable Force 95 25...

Страница 39: ...pin No Signal Name definition I O 1 RX1 Received data 1 Input I 2 RX1 Received data 1 Input I 3 TX1 Send data 1 Output O 4 TX1 Send data 1 Output O 5 Reserved Reserved signal line 6 Reserved Reserved...

Страница 40: ...tput in Quad mode I O IO6 CS Chip select output of negative logic O A IO7 TAUX3 I O terminal definition varies according to definition program I O A IO8 TAUX4 I O terminal definition varies according...

Страница 41: ...40 Interface circuit specification Type A Type B Type C 1M XV 7SZ125 68 47 VCX244 Internal power PHX401 side PHX401 side PHX401 side VCX244...

Страница 42: ...41 Type D Type E PHX401 side To XV 1M 220 TRES WDT User Target side XV To Output Buffer VCC PHX401 side...

Страница 43: ...42 Type F PHX401 side VCX244 2 5V...

Страница 44: ...low 17 GND yellow black 5 I O IO5 HOLD IO3 A brown 18 GND brown black 6 I O IO6 CS A blue 19 GND blue black 7 I O IO7 TAUX3 A orange 20 GND orange black 8 I O IO8 TAUX4 B grey 21 I O IO9 TMODE B grey...

Страница 45: ...Vin Maximum absolute rating 4 6 V Output voltage VoL Isink 3mA 0 7 V IO1 IO7 Output voltage VoH IoH 100uA XV 1 8V 1 6 V XV 2 3V 2 1 XV 3 0V 2 8 VoL IoH 100uA XV 1 8V 0 2 XV 2 3V 0 2 XV 3 0V 0 2 Output...

Страница 46: ...il SO output when SCK is falling Max 15ns This does not depend on the baud rate setting TVCC 1 8V TCLK SCK cycle time Min 50ns SCK 20MHz TTDIS SI setup time when TCK is rising Min 9ns This does not de...

Страница 47: ...46 5 2 3 PHX410 Dimensional drawing Below shows surface and pins configuration 95 L 65 W 25 H mm MC08P2LPG30XSB2 Cable Force 5 1 9 6 RDED 9SE1 M2 6 55 Hirose Electric Co LTD 95 25 300 2000 65...

Страница 48: ...gnal for CAN communication I O B TIO I O terminal definition varies according to definition program I O C TMODE I O terminal definition varies according to definition program I O C PROBE SELECT Termin...

Страница 49: ...uration circuit of terminating resistance Relay CANH User target side CAN Tr Relay s initial condition is OFF OPEN condition No terminating resistance CANL NET IMPRESS side NET IMPRESS side User targe...

Страница 50: ...49 Type D 3 3V Internal power 3 3V Internal power User target side NET IMPRESS side Probe Select User target side TMODE TIO 3 3V Internal power 3 3V Internal power Type C NET IMPRESS side 220 1M 220...

Страница 51: ...Pin No 1 I TVCCS A white 2 I O CANL B red 3 GND black 4 Reserved blue 5 Reserved purple 6 I O TIO C orange 7 I O CANH B yellow 8 I O TMODE C grey 9 I PROBE SELECT D light blue Signal Name Circuit Typ...

Страница 52: ...51 5 3 Optional cable 5 3 1 OCX100 AC code available only in Japan Cable type differs according to country For inquiry please contact your distributor or DTS INSIGHT CORPORATION...

Страница 53: ...Electric Co LTD HONDA TSUSHIN KOGYO CO LTD Pin No 1 9 VCC NETIMPRESS side 8 8 RSV 11 2 5 GND 9 6 RSV 3 3 RSV 10 5 4 12 6 13 7 14 2 RXD 7 RSV 4 NC 1 NC BCR side Signal name VCC RSV NC GND RSV RSV NC RX...

Страница 54: ...dots Digital I O IN1 15 Red 2 dots Digital I O IN2 16 Black 2 dots Digital I O IN3 17 Red 2 dots RSV 18 Black 2 dots DIVCC 19 Red 2 dots DOCOM 20 Black 2 dots DOVCC 21 Red 3 dots Digital I O OUT1 22 B...

Страница 55: ...54 5 4 Accessary 5 4 1 ACX100 SD card cover...

Страница 56: ...Q Main unit does not work Check the SD card If the dedicated SD card is broken NETIMPRESS avant may repeat the start up operation In that case remove the damaged SD card and replace it to the normal S...

Страница 57: ...your local distributors Contact NETIMPRESS Support Center E mail support impress dts insight co jp Shinjuku MIDWEST BLDG 4 30 3 Yoyogi Shibuya ku Tokyo 151 0053 Japan NETIMPRESS avant Hardware Manual...