20
13- REC MODE
DMX Recorder mode
For the programming of ChPr by using a DMX controller, besides the 10 channels necessary
to control the unit a further 3 DMX channels are needed.
So that in RECORDER mode (via DMX) the unit will need 13 channels to be correctly
programmed.
The three new DMX channels are:
DMX channel 11 = SCENES channel
From 0-10 = no function (r001)
From 11-255 are displayed the programmable scenes (max 16 scenes from M001 to M0016)
DMX channel 12 = EDIT channel:
-From 0-19 = no function
-From 20-234 the unit runs the configuration given by the received input DMX values.
With the channel SCENES it is possible to pass from one step to the next while with REC it is
possible to record the selected scene.
-From 235-255 the unit runs the configuration given by the received input DMX values closing
the sequence as last scene.
With the channel REC it is possible to record the selected scene as last scene.
DMX channel 13 = RECORDING channel
Records the set scene with a variation between 0 to 255 (the display flashes indicating that
the scene has been recorded). It is advised that you keep the REC channel set to 0 and to run
through the 255 only once you have decided to save the scene. If ChPr is not closed, by
indicating the last scene (Edit channel between 235-255), in playback mode all 16 scenes will
be played through even if not programmed.
14- ERROR MESSAGES
ERROR SHOWED ON DISPLAY
APPEARS WHEN
LED thermal sensor damaged (open or in
short circuit).
Unit immediately goes in black-out.
LED temperature detected over 100°C.
Unit immediately goes in black-out.
Micro controller thermal sensor damaged
(open or in short circuit).
Unit immediately goes in black-out.
Micro controller temperature detected over
100°C. Unit immediately goes in black-out.
Thermal sensor on outputs 1 and 2 of LED
Driver board damaged (open or in short
circuit).
Unit immediately goes in black-out.
Temperature detected over 100°C on
outputs 1 and 2 of LED Driver board. Unit
immediately goes in black-out.
Thermal sensor on outputs 3 and 4 of LED
Driver board damaged (open or in short
circuit).
Unit immediately goes in black-out.
Temperature detected over 100°C on
outputs 3 and 4 of LED Driver board. Unit
immediately goes in black-out.