RDM – DMX – Manual
Ver. 1.08
12 di 58
ALCHEMY
5
“Display Key-Lock” Function
This function can be enabled/disabled by contemporary pressing ENTER + DOWN keys for 3 seconds.
“Zero Skip” Function
“Zero skip” function can be activated by contemporary pressing MENU + UP during initial reset.
This function allows to have the display ON and all motors OFF. This can be useful when the unit, while still
being inside the flightcase, needs to be DMX-addressed or when its other parameters need to be set.
MAIN MENU
LEVEL 1
LEVEL 2
LEVEL 3
FUNCTION
NETWORK
INPUT
DISABLED
Allows to disable Ethernet
operation (Default).
ARTNET
Allows to select Art-Net as input
control signal protocol.
SACN
Allows to select sACN as input
control signal protocol.
IP ADDR MODE
DEFAULT
Allows to select the mode to set
the IP address and the Net
Mask.
Fixed IP address with manual
setting of first byte only and
fixed Net Mask (Default).
STATIC
Manual setting of IP address
and Net Mask.
DEFAULT IP
IP 2.214.192. 7
MASK 255. 0. 0. 0
Fixed IP address and Net
Mask. It is possible to set only
first byte of the IP address.
IP address must be different
for each unit on a network.
ARTNET UNIV.
00000 - 32767
Allows to set the Art-Net
Universe (range 0÷32767).
SACN
UNIVERSE
00001 - 63999
Allows to set the sACN
Universe (range 1÷63999).
Содержание ALCHEMY 5
Страница 1: ......
Страница 2: ......
Страница 60: ...RDM DMX Manual Ver 1 08 58 di 58 ALCHEMY 5 NOTES...
Страница 61: ......