FIRE HAZARD - NG and LP present a hazard of possible
explosion and/or fire.

a.

Do not smoke or use open flame near the generator
set.

b.

Keep a fire extinguisher nearby and know its proper use.
Fire extinguishers rated ABC by NFPA are appropriate.

3.

DEADLY EXHAUST GAS - Exhaust fumes from any gaso-
line engine contain carbon monoxide, an invisible, odorless
and deadly gas that must be mixed with fresh air.

a.

Operate only in well ventilated areas.

b.

Never operate indoors.

c.

Never operate the unit in such a way as to allow exhaust
gases to seep back into closed rooms (i.e. through
windows, walls or floors).

4.

NOISE HAZARD - Excessive noise is not only tiring, but
continual exposure can lead to loss of hearing.

a.

Use hearing protection equipment when working
around this equipment for long periods of time.

b.

Keep your neighbors in mind when permanently install-
ing  this equipment.

5.

CLEANLINESS - Keep the generator and surrounding area
clean.

a.

Remove all grease, ice, snow or materials that create
slippery conditions around the unit.

b.

Remove any rags or other material that could create
potential fire hazards.

c.

Carefully wipe up any gas or oil spills before starting the
unit.

d.

Never allow leaves or other flammable material to build
up around the engine exhaust area.

6.

SERVICING EQUIPMENT - All service, including the
installation or replacement of service parts, should be
performed only by a qualified technician.

a.

Use only factory approved repair parts.

b.

Do not work on this equipment when fatigued.

c.

Never remove the protective guards, cover, or recep-
tacle panels while the engine is running.

d.

Use extreme caution when working on electrical compo-
nents.  High output voltages from this equipment can
cause serious injury or death.

e.

Always avoid hot mufflers, exhaust manifolds, and
engine parts.  They all can cause severe burns instantly.

f.

Installing a generator set is not a “do-it-yourself” project.
Consult a qualified, licensed electrician or contractor.
The installation must comply with all national, state, and
local  codes.

g.

Always make sure unit is disabled before placing your
hands anywhere near the fan, belts, alternator or water
hoses.

IMPORTANT SAFETY
INSTRUCTIONS

SAVE THESE INSTRUCTION

This manual contains important instructions that
should be followed during installation and maintenance
of the generator and batteries.

Read and understand all instructions in the manual
before starting and operating the generator set.

This engine generator set has been designed and manufactured
to allow safe, reliable performance.  Poor maintenance, improper
or careless use can result in potential deadly hazards;  from
electrical shock, exhaust gas asphyxiation, or fire.  Please read
all safety instructions carefully before installation or use.  Keep
these instructions handy for future reference.  Take special note
and follow all warnings on the unit labels and in the manuals.

ANSI SAFETY DEFINITIONS

************************************************************

DANGER:

DANGER indicates an imminently hazardous situation which, if
not avoided, will result in death or serious injury. This signal word
is to be limited to the most extreme situations.
************************************************************

************************************************************

WARNING:

 WARNING indicates a potentially hazardous situation which, if
not avoided, could result in death or serious injury.
************************************************************

************************************************************

CAUTION:

CAUTION indicates a potentially hazardous situation which, if not
avoided, may result in minor or moderate injury. It may also be
used to alert against unsafe practices.
************************************************************

NOTE:

CAUTION is also used on the unit labels and in this manual to
indicate a situation that could result in serious damage or
destruction of the equipment and possible personal injury.

1.

ELECTRIC SHOCK -  The output voltage present in this
equipment can cause a fatal electric shock. This equipment
must be operated by a responsible person.

a.

Do not allow anyone to operate the generator without
proper instruction.

b.

Guard against electric shock.

c.

Avoid contact with live terminals or receptacles.

d.

Use extreme care if operating this unit in rain or snow.

e.

Use only three-prong grounded receptacles and
extension cords.

f.

Be sure the unit is properly grounded to an external
ground rod driven into the earth.

Содержание Winco PSS60-17

Страница 1: ...PACKAGE STANDBY SYSTEMS INSTALLATION AND OPERATIONS MANUAL PSS60 A PSS90 A ...

Страница 2: ...d SAVE THESE INSTRUCTIONS This manual contains important instructions that should be followed during installation and maintenance of the generator and batteries Read and understand all instructions in the manual before starting and operating the generator set USING THIS MANUAL Congratulations on your choice of a Winco generator set You have selected a high quality precision engineered generator se...

Страница 3: ...ctrician or contractor The installation must comply with all national state and local codes g Always make sure unit is disabled before placing your hands anywhere near the fan belts alternator or water hoses IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTION This manual contains important instructions that should be followed during installation and maintenance of the generator and batteries Read...

Страница 4: ...gine equipped to run on L P N G fuel The engine operates at 1800 rpm and frequency regulation is maintained by the electronic governor within 5 cycles variation from no load to rated load The 60 000 watt 60kW generator is a single bearing direct drive rotating field design The generator is connected to the engine flywheel via flexible drive disks The engine generator is mounted in a weather proof ...

Страница 5: ...temperature monitoring over crank protection ECU specific protection elements and diagnostic reporting Metered engine parameters include oil pressure coolant A Liquid Crystal Display The backlit 64 by 128 pixel LCD serves as the local information source for metering alarms pre alarms and protective functions Display operation is maintained at 20 C An optional LCD heater maintains display operation...

Страница 6: ...for setting or resetting the system clock 1 Press K right key for initial set or K left to back up up down to choose menu item and time date element to be changed 2 Press L Edit to access change mode to enter Password OP as follows 2a Press K up to select O 2b Press K right to move cursor 2c Press K up to select P 2d Press L Edit to begin change mode 3 Press K up or down to choose year 4 Press L E...

Страница 7: ...e engine s requirements and assist in making you aware of the decisions you must make In no case should the instructions or information provided be interpreted to conflict with any local state or national codes If in doubt always consult your local fire marshal or gas supplier WARNING FIRE HAZARD All fuel runs should be installed by a licensed fuel supplier The engine manufacturer has established ...

Страница 8: ...talled from the secondary regula tor to the generator set WARNING PERSONAL DANGER Do not use galvanized pipe in fuel line runs The galvanized coating can become eroded and flake off causing possible obstructions in the regulator or fuel valve The results could range from inoperative engine start to hazardous fuel leaks Size of pipe normally required for generators operating on NG LP up to 25 feet ...

Страница 9: ...formed or supervised only by personnel knowledgeable of batteries and the required precautions Keep unauthorized personnel away from batteries When installing or replacing batteries use the proper group size starting battery The battery should be a Maintenance Free lead acid design Deep cycle batteries will not work for this applica tion CAUTION PERSONAL DANGER CAUTION NEVER dispose of a battery i...

Страница 10: ... done by a licensed electri cian and must conform to the national electrical code and comply with all state and local codes and regulations Check with the local authorities before proceeding INSTALLATION NOTES Because of the many different types of service feeder and distribution equipment no specific wiring instructions can be provided It is recommended that only copper wire be used In all cases ...

Страница 11: ...50 MCM and should be torqued to 250 in lbs D 120 Volt Terminal Block This terminal block is provide for the 120 volt 15 amp feed from customers distrubution panel for the block heater and the trickle charger WARNING A main line circuit breaker has been provided inside the genera tor housing During all wiring installations make sure the breaker is in the off position and the generator operation swi...

Страница 12: ...will not start and run without either the jumper installed or a remote N C switch installed G Fuel Select Toggle Switch This SWITCH allows you to change the engine from one fuel to the other See Changing the Fuel Type for additional information H Remote Display Panel Interface Terminals These interface terminals are prewired to allow for the connection of a Basler RDP 110 remote display This displ...

Страница 13: ...e generator terminals in the Automatic Transfer Switch The voltage between the G1 and the G3 terminals should be the same as it was on the generator front panel The voltage should also be checked between the hot terminals G1 and G3 and the G N to be certain of a balanced voltage output and a solid neutral connection The voltage between G1 and G N should be about 120 volts AC 277 on 480 units The s...

Страница 14: ... 3 Governor is defective 4 AC short in generator components ATS PANEL WILL NOT TRANSFER TO EMERGENCY SUPPLY GENERATOR 1 No AC generator output from generator 2 Defective transfer switch controller 3 Incorrect voltage or frequecy for the generator 4 Wiring error between generator and transfer switch 5 Defective mechinally switching solenoid in Automatic Transfer Switch 6 Improper phase rotating ATS...

Страница 15: ...60706 194 Page 13 0210 10 ...

Страница 16: ...Page 14 0210 00 60706 194 THREE PHASE AC WIRING HIGH AND LOW WYE THREE PHASE LOW WYE 120 208 VOLTS THREE PHASE HIGH WYE 277 480 VOLTS ...

Страница 17: ...60706 194 Page 15 0210 10 THREE PHASE AC WIRING DELTA SINGLE PHASE AC WIRING SINGLE PHASE 120 240 VOLTS THREE PHASE DELTA 120 240 VOLTS ...

Страница 18: ...Page 16 0210 00 60706 194 VOLTAGE REGULATOR WIRING THREE PHASE AND SINGLE PHASE ...

Страница 19: ...60706 194 Page 17 0210 10 DC SCHEMATIC ...

Страница 20: ...e are limited to 12 months or 1000 hours which ever accurs first from date of purchase In no event is WINCO liable for incidental or consequential damages Note Some states do not allow limitation on the duration of implied warranty and some states do not allow the exclusion or limitation of incidental or consequential damages so the above limita tions may not apply in every instance This warranty ...