![DTI Dyna Technology ULPSS8B4W/E Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/dti-dyna-technology/ulpss8b4w-e/ulpss8b4w-e_installation-instructions_2535872003.webp)
225 S. CORDOVA AVE.
LECENTER, MN 56057
507-357-6821
SERVICE DEPT.
507-357-6831
the wiring harness through the hold and
pushing the controller back into position.
12. Re-install the 6 torx screws “G”.
13. Re-install the plastic grommet “H”.
14. Re-connect the wiring harness “D”.
15. Connect 2-wire white connector “E”
to the matching connector “I” on the
bottom of the new controller.
16. Replace the circuit breaker cover
panel and re-install the 2 bolts “B”.
17. Remove left side door.
18. Replace left side door.
19. Re-attach the battery cable if done so earlier.
20. Replace the right side access panel and roof.
21. Remove the operators manual part # 60706-210 for model ULPSS8B4W/E
from the literature package and replace it with operators maual part # 60706-211 for
model ULPSS8B2W/E. This replacement manual contains the proper information for
installation and operation of a 2-wire auto start system. The customer must have this
manual in order to start and operate the unit after the installation of the new engine
control.
22. Replace the rear door.
23. Using the new operators manual, 60706-211, this unit is now ready to be in-
stalled as a standard 2-wire start system. This generator set will now work with any
transfer switch that provides a ‘dry’ relay closure for a start/run signal.
If you have any problems or need assistance,
feel free to contact the WINCO Service
Department at 507-357-6831.
60710-125-11078-00