PULSE COUNT
-
This is the number of times the unit has to detect on both of its sensors before
signalling an output.
LED MONITOR
LED Off - LED disabled
LED On - LED signals a detection
LUX SETTING
-
This is the approximate level that the ambient light must reach before the 'S'
output will become active when there is an activation.
The 'S' output switches negative for 60 seconds when there is a detection and
the light level is below the programmed setting.
The 'S' output is an open collector type rated at a maximum of 25 mA.
CCTV1 & CCTV2 OUTPUTS
-
These are magnetically immune volt free relay contacts used to trigger alarm
inputs on connected equipment. They can be set to be both normally open, one
normally closed and one normally open or both normally closed.
TIMER
-
The timer setting adjusts the time that the relays change state after activation.
The contacts are rated at a maximum of 24V AC/DC @ 50 mA.
ACCESSORIES
GJD is able to supply the following accessories to aid installations:
GJD303
Infra Red key fob programmer
GJD304
Conduit cable entry adaptor ring
GJD305
Pole mount clamp