background image

 

FRONT PANEL 
 

 

 

 

 

 

 
 
 
 
REAR PANEL    & CONNECTIONS 
 

 

 

 

   

 

 
 

                                               

 

 

 

 

 

 

 

ALARM IN

 

to be connected to fire center

 

 

 

 

 

 

 

l

 

1~10

 

Live Terminals of CH1~CH10 respectively 

l

 

11~25

 

COM 

1      2      3    4      5      6      7    8    9    10    11 12    13 

  14    15

 ,

16

 ,

17    18    19

 ,

20    21

22    23 

,

24 

,

25 

 

Power Amp. A   

    MP series 

for BGM

 

 

Power Amp. B 

    MP series 

for EMC

 

ALM OUTPUT

 to 

Timer / Siren Device 

Emergency 
from FIRE center* 

Input level   
preset

 

MP9914T 

To MP9906D 

or MP9907C 

                     

1

   

2

   

4                   5                 6

   

Power switch (1 is power on and the 

power LED

 is on ) 

     

Power indicator                                 

Switching key

 

Switch indicator

                 

6

 All call button 

Output

 

indicator

                                7

 All call indicator 

Содержание MP9913B

Страница 1: ...NER S MANUAL Before operating please read this manual completely FEATURES l 2CH inputs 10CH outputs l Hi Low alarm level available l The channel will be switched to input B automatically while alarming l Alarm indicator and output indicator ...

Страница 2: ...2 Left blank for memo ...

Страница 3: ...6 17 18 19 20 21 22 23 24 25 Power Amp A MP series for BGM Power Amp B MP series for EMC ALM OUTPUT to Timer Siren Device Emergency from FIRE center Input level preset MP9914T To MP9906D or MP9907C 1 2 3 4 5 6 7 1 Power switch 1 is power on and the power LED is on 2 Power indicator 5 Switching key 3 Switch indicator 6 All call button 4 Output indicator 7 All call indicator ...

Страница 4: ...et at Low 0V grounded signal is valid Every channel will be switched to B while alarm signal is fed to ALARM IN and the Switch indicator will be flashing quickly 5 An grounded Alarm signal will be sent out from ALARM OUT while any alarm signal appears on ALARM INPUT SPECIFICATIONS Channels 10 switchable Input capacity 70 100 V 10 A output capacity 70 100 V 5 A CH ALM 10 CHs 5 24 V 0 according to p...

Страница 5: ...5 MP 9913B 广播分区器 使用说明 欢迎惠顾 您对本产品之选用显示了您的专业眼光 使用前请详细阅读本说明书 性能特点 l 2 路输入 A 和 B 10 通道输出 l 2 种输入告警电平选择 l 紧急广播强插功能 l 一目了然的告警指示和输出信号指示 ...

Страница 6: ...6 此页留空供用户记事 ...

Страница 7: ...11 25 公共端 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 A 功放 MP 系列 背景音乐 B 功放 MP 系列 紧急广播 报警信号输出 去定时器 报警器 警报信号 来自消防中心 告警设定 接 MP9914 接 MP9906D 或 MP9907C 1 2 3 4 5 6 7 1 电源开关 按下 1 为电源接通状态且电源指示灯亮 2 电源指示 5 分区选择键 3 分区选通指示 6 全开全关控制开关 4 输出指示 7 全开全关指示 ...

Страница 8: ... 输入电流小于 3mA 当告警设定开关置于 High 时 正信号有效 当该设定开关置 于 Low 时 短路信号有效 有告警时相应通道扬声器乃自动强切到 B 输入 且对应的分区选 通指示灯会快速闪烁 5 警报输入口 ALARM INPUT 任一端子有警报信号输入时 报警信号输出口 ALARM OUT 即有报警信号输出 可用于启动处于待机状态的定时器以及激发警报信号发生器 性能规格 通道数 10 可任意选通 输入容量 70 100 V 10A 功率输入 输出容量 每个通道 70 100V 5A 功率输出 警报信号 5V 24V 0V 0 5V 短路 可预置 保护 AC 保险丝 1 电源 AC 220 240 V 50 60Hz 尺寸 485 88 375mm 毛重 6 5kg 净重 5 2kg 性能规格如有改变恕不另行通知 注 意 本设备的电源开关在 断 状态时 机器并未与电网电源完全断开 为...