Fire Fighting

/

Public Broadcast System

 

Simple Addressable Broadcast System

 

 

 

Addressable  Control  Host 

used to control the volume of the input channels respectively. Knob 

MIC VOL

 is used to control 

the  volume  of  microphone.  Clockwise  turning  represents  volume  increase,  while  anticlockwise 

turning represents volume decrease.   

Volume  of the 100 zones  is integratedly controlled by the knob  on the  panel  of the equipment, i.e.. 

the equipment is not provided with separate control for simultaneous volume increase or decrease for 

the 100 zones.   

 

4.4  Paging and Priority Functions     

Paging includes remote  paging and  paging  of  microphone connected to the  equipment.  The  control 

of zones by the remote pager enjoys  priority  over addressable host and PC  control software. When 

the zones are switched  upon on the remote  pager  for paging, the five zone scope selection  keys  on 

the panel of the equipment can be used to view the operation status of zones during the paging. Any 

operation  over  the  zones  by  addressable  host  and  PC  control  software  other  than  the  operation  by 

remote pager will be invalid.   

When the remote pager is conducting paging operation for a particular zone, if the zone is switched 

on on the remote pager, then all the zones for background music will be switched off, then the paged 

zone  will  be  switched  on.  After  the  paging,  use  key 

ALL  OFF

  on  the  pager  to  switch  off  all  the 

zones or the power of remote pager, and all the zones will resumed to the pre-paging operation status.   

When  the  pager  is  conducting  paging  for  all  the  zones,  gently  press 

ALL  ON

  key  on  the  remote 

pager  to  switch  on  all  the  zones.  In  this  case,  the  equipment  will  switch  off  the  zone  playing 

background music first, then switch on all the zones. After the paging, gently press key 

ALL OFF

 

on the pager to resume the status of playing background music of the zones.     

The system can also perform paging over the zones by the microphone connected to the equipment. 

Prior  to  the  paging,  gently  press  the  key  for  ringing  alert

  on  the  panel  to  obtain  the  ringing  tone. 

Ringing  volume  can  be  adjusted  by  the  ringing  volume  adjustment  knob  (1)  on  the  panel  of  the 

equipment. Adjust the microphone volume to the optimal position (until no howl is available for the 

microphone), and then carry out paging for the zones.     

When  the  system  is  playing  the  audio  input  by  AUX1  interface,  paging  over  zones  can  also  be 

performed by  microphone. Input signal  of  AUX1 interface and ringing signal are the same  priority 

signal,  and  the  output  terminal  can  transmit  three  signals,  any  of  which  can  cover  the  audio  signal 

input by AUX2, AUX3 and AUX4.     

 

Note for Operation: 

 

1. 

When the host is off, at least 10 minutes is required for re-energization.   

2. 

When withdrawing from the remote paging (by pressing key 

ALL OFF

 of the remote pager), 

please power off the microphone of remote pager at the same time, otherwise, the surrounding 

sounds can still reach the zones switched on after the resuming via the microphone of pager.   

Содержание ADR6435

Страница 1: ...ressable PA Amplifier Operation Instructions Welcome to DSPPA public broadcast system For better use of the equipment please read the manual carefully before operation Guangzhou DSPPAAudio Co Ltd http www DSPPA com ...

Страница 2: ...uipment to broadcast music programs for zones In addition the equipment is also provided with remote paging extension interface for connection with remote pager The system composed by the equipment meets the requirements of the broadcast of schools factories gardens office buildings shopping malls stations and docks 1 2 Function Features l Simple addressable public broadcast system l Addressable c...

Страница 3: ...cator 3 Resume 4 All On 5 All Off 6 Aux volume 7 MIC Volume 8 MIC in 9 Output level 10 Range select 11 Indirect select 12 Chime 2 2 Description of Rear Panel 1 Chime volume 2 Aux Audio input 3 Aux Audio output 4 Paging input 5 PC input jack 6 AC220V Power jack 7 AC220V fuse 8 cooling blower fan 9 Control output COM 10 Control output 100V jack 1 9 10 11 12 2 3 4 5 6 7 8 1 2 3 4 5 7 6 8 10 9 ...

Страница 4: ...Simple Addressable Broadcast System Addressable Control Host 4 3 Example of System Connection TAPE The acoustic band decoder TUNER RECORDER CDPLAY Paging Selector TAPE TUNER RECORDER CDPLAY Paging Selector DEC DEC Speaker Speaker DEC Speaker ...

Страница 5: ...is used for controlling the 81st to 100th zones Key ALL ON is used for switching on all the zones 100 zones After switching on all the zones in case of a need to switch off a particular or certain zones please select the related scope of the zone with zone scope selection key and then shut off all zones not required with zone control key Key ALL ON is used for switching off all the zones 100 zones...

Страница 6: ...the zones or the power of remote pager and all the zones will resumed to the pre paging operation status When the pager is conducting paging for all the zones gently press ALL ON key on the remote pager to switch on all the zones In this case the equipment will switch off the zone playing background music first then switch on all the zones After the paging gently press key ALL OFF on the pager to ...

Страница 7: ...long time l It is required to pull out the power plug to ensure that the equipment is completely disengaged from the power network when it is to dis assemble or re assemble any part of the equipment or to disconnect or connect plug of any electric apparatus of equipment or making other connection l When the equipment has a failure it is not allowed for the non professional personnel to open the ho...

Страница 8: ...d the company shall not take the responsibility to repair free of charge if the damage is due to dis assembling by yourself or from the repair by the technical personnel not from the company 6 Performance Specifications 1 Speaker output 100V 2 Rated output 350W 3 Frequency response 50Hz 16KHz 3dB 4 Total harmonic distortion 0 5 5 S N ratio A weighted 80dB Minimum power emf AUX 200mV 6 Minimum powe...

Отзывы: