![DSE DX Series Скачать руководство пользователя страница 40](http://html.mh-extra.com/html/dse/dx-series/dx-series_configuration-manual_2534964040.webp)
CONFIGURATION MANUAL
Video recorders DX Series
Page:
40
Page:
40
DSE SRL - ITALY - WWW.DSE.EU
through the rear RS485 port. The second "RS485 device" column is not active.
● CHANNEL - The channel to which you refer.
● PROTOCOL - And 'the language to be used on the RS-485 bus to send commands to the camera. Specify the protocol to use in
verifying that it is the same one used by the camera. The DVR supports many protocol: Pelco P and Pelco D in all its variants (for use
with DSE speed dome cameras), HY, LG, Panasonic, Philips, Samsung, Sharp, Sony, etc. Yaan
● ADDRESS - Every speed dome camera has distinguished along the bus by his unique address that the program typically through
internal switches. Insert here the address assigned to the camera (0 to 255)
● BAUDRATE - And 'the rate to be used on the RS-485 bus to send commands to the camera. Specify the bit rate to use in verifying that
it is the same set in the camera. The DVR support from 1200 to 115200 baud.
● DATA BITS / STOP / PARITY '- Remaining protocol data which is normally no need to change.
OSD MENU / SYSTEM / DISPLAY
overlays Management
Here we define the information to be superimposed in the LIVE Vision (top section - SCENE) and recording (Lower Section RECORD
OVERLAY)
● CHANNEL NAME - Pressing the SET button will engage the identification name of each channel
● DATE / TIME / TITLE / ALL STATE REG./STATO. - You can enable / disable these