background image

 

The power plug has to be accessible after installing the fixture. Do not 

overload wall outlets and extension cords as this can result in fire or electric 
shock.  

DO NOT

 allow anything to rest on the power cord. 

DO NOT

 locate this 

fixture where the cord may be damaged by persons walking on it. 

Make sure that the power cord is never crimped or damaged by sharp 

edges. Check the fixture and the power cord from time to time. 

Refer servicing to qualified service personnel. 

 

 

This fixture falls under protection class I. Therefore this fixture has to 
be connected to a mains socket outlet with a protective earthing 
connection.

 

DO NOT

 connect this fixture to a dimmer pack. 

 

 

LED light emission. Risk of eye injury. DO NOT look into the beam at a 
distance of less than 1 meter from the front surface of the product. Do 
not view the light output with optical instruments or any device that 
may concentrate the beam.

 

 

If the fixture has been exposed to drastic temperature fluctuation (e.g. 

after transportation), 

DO NOT

 switch it on immediately. The arising 

condensation water might damage your device. Leave the device switched 
off until it has reached room temperature. 

DO NOT

 shake the fixture. Avoid brute force when installing or operating 

the fixture. 

This fixture was designed for indoor use only, do not expose this unit to 

rain or use near water. 

When choosing the installation spot, please make sure that the fixture is 

not exposed to extreme heat, moisture or dust. 

 

 

Do not block the LEDs array with any object when the fixture is under 
operation

 

 

The openings should never be covered with cloth or other materials, and 

never must be blocked. This fixture should not be placed in a built-in 
installation unless proper ventilation is provided. 

 
Only operate the fixture after having checked that the housing is firmly 

closed and all screws are tightly fastened. Always use a secondary safety 
cable when mounting this fixture. 

 
Make sure that the area below the installation place is blocked when 

rigging or servicing the fixture. 

DO NOT

 block the front objective LEDs with 

any object when the fixture is under operation. 

Содержание 18*4in1 15W Diamond Moving

Страница 1: ...18 4in1 15W Diamond Moving USER MANUAL Please read the instructions carefully before use...

Страница 2: ...ervance of this manual or any unauthorized modification to the device Please consider that damages caused by manual modifications to the device are not subject to warranty 1 Safety Instructions Please...

Страница 3: ...perature fluctuation e g after transportation DO NOT switch it on immediately The arising condensation water might damage your device Leave the device switched off until it has reached room temperatur...

Страница 4: ...revent or reduce the risk of electrical shock or fire DO NOT expose the unit to rain or moisture 2 DO NOT open the unit within five minutes after switching off 3 The housing the lenses or the ultravio...

Страница 5: ...Weight 9 86Kgs Gross Weight 12Kgs CONTROL DMX Channel 20 40 Channel Control Modes DMX512 PAN TILT Pan Tilt 540 180 Pan Tilt Resolution 16 bit CONSTRUCTION Display LCD Display Data In Out socket 3 pin...

Страница 6: ...e signal DISPLAY MENU To select the programming functions DOWN To go backward in the selected functions UP To go forward in the selected functions ENTER To confirm the selected functions SET DMX ADDRE...

Страница 7: ...ed 1 2 0 99 70 Pan scan opposition title scan opposition scan angle select scan mode select mic sensitivity Temp C F C F reload the default parameter Reset Default ON OFF Re load all delivery paramete...

Страница 8: ...er Mode 0 49 Dimmer1 50 99 Dimmer2 100 149 Dimmer3 150 255 Dimmer4 9 9 Rotation 0 127 0 60 locating 128 190 Rotation Reverse max to min speed 191 192 Rotation Stop 193 255 Rotation Forward min to max...

Страница 9: ...0 Black 255 100 Blue 17 White LED array 2 0 255 White 0 Black 255 100 White 18 Red LED array 3 0 255 Red 0 Black 255 100 Red 19 Green LED array 3 0 255 Green 0 Black 255 100 Green 20 Blue LED array 3...

Страница 10: ...255 100 Red 31 Green LED array 6 0 255 Green 0 Black 255 100 Green 32 Blue LED array 6 0 255 Blue 0 Black 255 100 Blue 33 White LED array 6 0 255 White 0 Black 255 100 White 14 34 Rainbow 0 4 No funct...

Страница 11: ...5 39 Color1 40 44 Color2 45 49 Color3 50 54 Color4 55 59 Color5 60 64 Color6 65 69 Color7 70 74 Color8 75 79 Color9 80 84 Color10 85 89 Color11 90 94 Color12 95 99 Color13 100 104 Color14 105 109 Colo...

Страница 12: ...14 Led trun off 15 30 Chase 1 31 46 Chase 2 47 62 Chase 3 63 78 Chase 4 79 94 Chase 5 95 110 Chase 6 111 126 Chase 7 127 142 Chase 8 143 158 Chase 9 159 174 Chase 10 175 190 Chase 11 191 206 Chase 12...

Страница 13: ...12 20 40 Lamp on off reset internal programs 0 79 Normal 80 99 All motor reset 100 255 Normal 4 Shape...

Страница 14: ...other DMX controller 5 Check if the DMX cables run near or run alongside to high voltage cables that may cause damage or interference to DMX interface circuit C One of the channels is not working well...